Use of a percutaneous vascular suture device for closure of an inadvertent subclavian artery puncture

被引:30
作者
Fraizer, MC [1 ]
Chu, WW [1 ]
Gudjonsson, T [1 ]
Wolff, MR [1 ]
机构
[1] Univ Wisconsin Hosp & Clin, Sect Cardiovasc Med, Madison, WI 53792 USA
关键词
central venous catheterization; Perclose; hemostasis; complications;
D O I
10.1002/ccd.10545
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
A well-known complication of central venous catheterization is inadvertent arterial sheath placement. Sheath removal from noncompressible arteries has the potential for severe complications. We report a case of inadvertent subclavian arterial sheath placement during an attempted internal jugular venous catheterization. This was successfully removed using a percutaneous vascular suture device. (C) 2003 Wiley-Liss, Inc.
引用
收藏
页码:369 / 371
页数:3
相关论文
共 7 条
[1]   Balloon tamponade for the treatment of inadvertent subclavian arterial catheter placement [J].
Alexander, JR ;
Weeks, SM ;
Sandhu, J ;
Mauro, MA ;
Jaques, PF .
JOURNAL OF VASCULAR AND INTERVENTIONAL RADIOLOGY, 2000, 11 (07) :875-877
[2]  
BERHET MH, 2001, CARDIOVASC INTERVENT, V24, P122
[3]   Use of a collagen plug device to seal a subclavian artery puncture secondary to intraarterial dialysis catheter placement [J].
Dowling, K ;
Herr, A ;
Siskin, G ;
Sansivero, GE ;
Stainken, B .
JOURNAL OF VASCULAR AND INTERVENTIONAL RADIOLOGY, 1999, 10 (01) :33-35
[4]   FATAL SUBCLAVIAN ARTERY HEMORRHAGE - A COMPLICATION OF SUBCLAVIAN VEIN CATHETERIZATION [J].
MERCERJONES, MA ;
WENSTONE, R ;
HERSHMAN, MJ .
ANAESTHESIA, 1995, 50 (07) :639-640
[5]  
OPHIUS AJO, 1998, PACING CLIN ELECTROP, V21, P2673
[6]   CENTRAL VEIN CATHETERIZATION - FAILURE AND COMPLICATION RATES BY 3 PERCUTANEOUS APPROACHES [J].
SZNAJDER, JI ;
ZVEIBIL, FR ;
BITTERMAN, H ;
WEINER, P ;
BURSZTEIN, S .
ARCHIVES OF INTERNAL MEDICINE, 1986, 146 (02) :259-261
[7]   INTERNAL BALLOON TAMPONADE - A NONSURGICAL METHOD FOR REMOVAL OF ACCIDENTALLY PLACED SHEATHS FROM THE SUBCLAVIAN ARTERY [J].
VANDIJK, RB ;
DENHEIJER, P ;
DEMUINCK, E ;
LIE, KI .
CATHETERIZATION AND CARDIOVASCULAR DIAGNOSIS, 1993, 29 (04) :325-328