Seismic assessment of a R/C strategic existing building

被引:2
|
作者
Mehani, Youcef [1 ]
Kibboua, Abderrahmane [1 ]
机构
[1] CGS, Natl Earthquake Engn Ctr, Algiers, Algeria
关键词
vulnerability; structural capacity; non linear dynamic analysis; strengthening;
D O I
10.12989/sem.2007.26.6.617
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Algeria is a country with a high seismic activity. During the last decade, many destructive earthquakes occurred, particularly in the northern part, causing enormous losses in human lives, buildings and equipments. In order to reduce this risk in the capital and avoid serious damages to the strategic existing buildings, the government decided to invest into seismic upgrade, strengthening and retrofitting of these buildings. In doing so, seismic vulnerability study of this category of buildings has been considered. Structural analysis is performed on the basis of site investigation (inspection of the building, collecting,data, materials, general conditions of the building, etc), and existing drawings (architectural plans,,structural design, etc). The aim of these seismic vulnerability studies is to develop guidelines and a methodology for rehabilitation of existing buildings. This paper will provide insight to the vulnerability assessment and strengthening of the telecommunication centre, according to the new code RPA 99/version 2003. Both, static equivalent method and non linear dynamic analysis are performed in this study.
引用
收藏
页码:617 / 634
页数:18
相关论文
共 50 条
  • [1] Seismic Assessment of Existing Masonry Building
    Osmanovic, Nadzija
    Medic, Senad
    Hrasnica, Mustafa
    ADVANCED TECHNOLOGIES, SYSTEMS, AND APPLICATIONS III, VOL 2, 2019, 60 : 52 - 61
  • [2] Seismic Assessment and Strengthening of an Existing Industrial Building
    Tartaglia, Roberto
    Prota, Alessandro
    Milone, Aldo
    Di Lorenzo, Gianmaria
    Landolfo, Raffaele
    PROCEEDINGS OF THE 10TH INTERNATIONAL CONFERENCE ON BEHAVIOUR OF STEEL STRUCTURES IN SEISMIC AREAS, STESSA 2022, 2022, 262 : 966 - 974
  • [3] Experimental study on seismic retrofit for existing R/C building by using CHS bracing
    Miyagawa, K
    Kinoshita, R
    Fujinaga, T
    Ohtani, Y
    Mitani, I
    ADVANCES IN STRUCTURES, VOLS 1 AND 2, 2003, : 1383 - 1390
  • [4] Seismic performance evaluation of Indonesian existing R/C building considering brick infill
    Maidiawati
    Agus
    Sanada, Yasushi
    Tanjung, Jafril
    3RD INTERNATIONAL CONFERENCE ON SUSTAINABLE CIVIL ENGINEERING STRUCTURES AND CONSTRUCTION MATERIALS - SUSTAINABLE STRUCTURES FOR FUTURE GENERATIONS, 2017, 171 : 1043 - 1051
  • [5] SEISMIC RELIABILITY ASSESSMENT OF EXISTING R/C FLAT-SLAB BUILDINGS
    LUO, YH
    DURRANI, A
    CONTE, J
    JOURNAL OF STRUCTURAL ENGINEERING-ASCE, 1995, 121 (10): : 1522 - 1530
  • [6] Seismic reliability assessment of existing R/C flat-slab buildings
    Zentech Inc, Houston, United States
    J Struct Eng, 10 (1522-1530):
  • [7] RAPID ASSESSMENT OF SEISMIC DEMAND IN EXISTING BUILDING STRUCTURES
    Tsang, Hing-Ho
    Su, Ray K. L.
    Lam, Nelson T. K.
    Lo, S. H.
    STRUCTURAL DESIGN OF TALL AND SPECIAL BUILDINGS, 2009, 18 (04): : 427 - 439
  • [8] Seismic loss assessment of existing hotel building in Ecuador
    Poveda, Jose
    O'Reilly, Gerard J.
    EARTHQUAKE SPECTRA, 2025, 41 (01) : 955 - 978
  • [9] Seismic Vulnerability and Damage Assessment of an Existing URM Building
    Remki, Mustapha
    Chikh, Benazouz
    Kibboua, Abderrahmane
    Kehila, Fouad
    Mehani, Youcef
    Fettar, Boubakeur
    IRANIAN JOURNAL OF SCIENCE AND TECHNOLOGY-TRANSACTIONS OF CIVIL ENGINEERING, 2019, 43 (Suppl 1) : 569 - 581
  • [10] Seismic Vulnerability and Damage Assessment of an Existing URM Building
    Mustapha Remki
    Benazouz Chikh
    Abderrahmane Kibboua
    Fouad Kehila
    Youcef Mehani
    Boubakeur Fettar
    Iranian Journal of Science and Technology, Transactions of Civil Engineering, 2019, 43 : 569 - 581