Optimal Beamforming in Ultrasound Using the Ideal Observer

被引:13
作者
Abbey, Craig K. [1 ,2 ]
Nguyen, Nghia Q. [3 ,4 ,5 ]
Insana, Michael F. [3 ,4 ,5 ]
机构
[1] Univ Calif Santa Barbara, Dept Psychol, Santa Barbara, CA 93106 USA
[2] Univ Calif Davis, Dept Biomed Engn, Davis, CA 95616 USA
[3] Univ Illinois, Dept Bioengn, Urbana, IL 61801 USA
[4] Univ Illinois, Dept Elect & Comp Engn, Urbana, IL 61801 USA
[5] Univ Illinois, Beckman Inst Adv Sci & Technol, Urbana, IL 61801 USA
基金
美国国家卫生研究院;
关键词
CYSTIC RESOLUTION; PERFORMANCE;
D O I
10.1109/TUFFC.2010.1616
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
Beamforming of received pulse-echo data generally involves the compression of signals from multiple channels within an aperture. This compression is irreversible, and therefore allows the possibility that information relevant for performing a diagnostic task is irretrievably lost. The purpose of this study was to evaluate information transfer in beamforming using a previously developed ideal observer model to quantify diagnostic information relevant to performing a task. We describe an elaborated statistical model of image formation for fixed-focus transmission and single-channel reception within a moving aperture, and we use this model on a panel of tasks related to breast sonography to evaluate receive-beamforming approaches that optimize the transfer of information. Under the assumption that acquisition noise is well described as an additive wide-band Gaussian white-noise process, we show that signal compression across receive-aperture channels after a 2-D matched-filtering operation results in no loss of diagnostic information. Across tasks, the matched-filter beamformer results in more information than standard delay-and-sum beamforming in the subsequent radio-frequency signal by a factor of two. We also show that for this matched filter, 68% of the information gain can be attributed to the phase of the matched-filter and 21% can be attributed to the amplitude. A 1-D matched filtering along axial lines shows no advantage over delay-and-sum, suggesting an important role for incorporating correlations across different aperture windows in beamforming. We also show that a post-compression processing before the computation of an envelope is necessary to pass the diagnostic information in the beamformed radio-frequency signal to the final envelope image.
引用
收藏
页码:1782 / 1796
页数:15
相关论文
共 20 条
[1]   Observer efficiency in discrimination tasks simulating malignant and benign breast lesions imaged with ultrasound [J].
Abbey, CK ;
Zemp, RJ ;
Liu, J ;
Lindfors, KK ;
Insana, MF .
IEEE TRANSACTIONS ON MEDICAL IMAGING, 2006, 25 (02) :198-209
[2]  
ABBEY CK, 2006, SPIE MED IMAGING
[3]  
Angelsen B.A. J., 2000, Ultrasound Imaging: Waves, Signals, and Signal Processing, V1
[4]  
ANGELSEN BAJ, 2000, ULTRASOUND IMAGING W, V2
[5]  
[Anonymous], 1983, Medical Imaging Systems
[6]  
[Anonymous], 1988, Signal Detection Theory and Psychophysics
[7]   Objective assessment of image quality. III. ROC metrics, ideal observers, and likelihood-generating functions [J].
Barrett, HH ;
Abbey, CK ;
Clarkson, E .
JOURNAL OF THE OPTICAL SOCIETY OF AMERICA A-OPTICS IMAGE SCIENCE AND VISION, 1998, 15 (06) :1520-1535
[8]  
Bracewell R.N., 1986, FOURIER TRANSFORM IT
[9]  
Golub GH., 1989, MATRIX COMPUTATIONS, DOI DOI 10.56021/9781421407944
[10]   Generalized Cystic Resolution: A Metric for Assessing the Fundamental Limits on Beamformer Performance [J].
Guenther, Drake A. ;
Walker, William F. .
IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 2009, 56 (01) :77-90