Ozonation combined with ultrasound for the degradation of tetracycline in a rectangular air-lift reactor

被引:89
作者
Wang, Yan [1 ]
Zhang, Hui [1 ]
Chen, Lu [1 ]
Wang, Sheng [1 ]
Zhang, Daobin [1 ]
机构
[1] Wuhan Univ, Dept Environm Engn, Wuhan 430079, Peoples R China
关键词
Ozone; Ultrasonic irradiation; Tetracycline; Rectangular air-lift reactor; Acute toxicity; LIQUID MASS-TRANSFER; AQUEOUS-SOLUTION; SONOLYTIC DECOMPOSITION; VETERINARY ANTIBIOTICS; OZONE; KINETICS; IRRADIATION; MECHANISM; WATER; COMBINATION;
D O I
10.1016/j.seppur.2011.06.035
中图分类号
TQ [化学工业];
学科分类号
0817 ;
摘要
The application of ozonation has been limited by the poor mass transfer rate of ozone. In the presence of ultrasonic irradiation, mass transfer of ozone to the liquid phase could be enhanced and hydroxyl radicals may be generated by the decomposition of ozone in the gas phase. This study is to combine ozone with ultrasound (US/O-3) for the removal of tetracycline (TC). The effect of several operational parameters, including gaseous ozone concentration, gas flow rate, hydrogen peroxide concentration, hydroxyl radical scavenger, pH, initial TC concentration and power density on the removal of TC was investigated. The results showed that the TC removal followed pseudo-first-order kinetics. The IC removal rate increased with increasing gaseous ozone concentration, gas flow rate and power density, but decreased with increasing initial TC concentration. The presence of hydrogen peroxide improved the TC removal rate when the hydrogen peroxide concentration was not exceeded 10 mmol L-1. The presence of tert-butyl alcohol inhibited the TC removal rate to some extent. The main intermediates were identified and the degradation pathway of TC was proposed. After 90 min treatment, 91% COD was removed. The acute toxicity of the solution reached the maximum after 10 min treatment and then gradually decreased with the prolonging reaction time. (C) 2011 Elsevier B.V. All rights reserved.
引用
收藏
页码:138 / 146
页数:9
相关论文
共 53 条
[1]  
APHA-AWWA-WPCF, 1998, STAND METH EX WAT WA
[2]   Ozonation of Procaine Penicillin G formulation effluent - Part I: Process optimization and kinetics [J].
Arslan-Alaton, I ;
Caglayan, AE .
CHEMOSPHERE, 2005, 59 (01) :31-39
[3]   Degradation of tetracycline by photo-Fenton process - Solar irradiation and matrix effects [J].
Bautitz, Ivonete Rossi ;
Nogueira, Raquel F. Pupo .
JOURNAL OF PHOTOCHEMISTRY AND PHOTOBIOLOGY A-CHEMISTRY, 2007, 187 (01) :33-39
[4]  
Boilyky L.J., 1981, OZONE-SCI ENG, V3, P181
[5]   Phenol degradation using 20, 300 and 520 kHz ultrasonic reactors with hydrogen peroxide, ozone and zero valent metals [J].
Chand, Rashmi ;
Ince, Nisun H. ;
Gogate, Parag R. ;
Bremner, David H. .
SEPARATION AND PURIFICATION TECHNOLOGY, 2009, 67 (01) :103-109
[6]   Two-phase hydrodynamic study of a rectangular air-lift loop reactor with an internal baffle [J].
Couvert, A ;
Roustan, M ;
Chatellier, P .
CHEMICAL ENGINEERING SCIENCE, 1999, 54 (21) :5245-5252
[7]  
DAHI E, 1976, WATER RES, V10, P677
[8]   Monitoring the degradation of tetracycline by ozone in aqueous medium via atmospheric pressure ionization mass spectrometry [J].
Dalmazio, Ilza ;
Almeida, Mariana O. ;
Augusti, Rodinei ;
Alves, Tania M. A. .
JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY, 2007, 18 (04) :679-687
[9]  
Diirckheimer W., 1975, ANGEW CHEM, V14, P721
[10]   ANALYSIS OF OZONE AT LOW CONCENTRATIONS WITH BORIC-ACID BUFFERED KL [J].
FLAMM, DL .
ENVIRONMENTAL SCIENCE & TECHNOLOGY, 1977, 11 (10) :978-983