Intraoral piezosurgery:: Preliminary results of a new technique

被引:134
作者
Stübinger, S
Kuttenberger, D
Filippi, A
Sader, R
Zeilhofer, HF
机构
[1] Univ Basel Hosp, Div Cranio & Maxillofacial Surg, Clin Reconstruct Surg, CH-4031 Basel, Switzerland
[2] Kantonsspital Luzern, Clin Oral & Maxillofacial Surg, Luzern, Switzerland
[3] Univ Basel, Dept Oral Surg, Basel, Switzerland
关键词
D O I
10.1016/j.joms.2005.05.304
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
The piezosurgery instrument, developed in 1988, uses a modulated ultrasonic frequency that permits highly precise and safe cutting of hard tissue. Nerves, vessels, and soft tissue are not injured by the microvibrations (60 to 200 mm/sec), which are optimally adjusted to target only mineralized tissue. The selective and thermally harmless nature of the piezosurgery instrument results in a low bleeding tendency. In addition, the instrument can be used in operations requiring either local or general anesthesia. The precise nature of the instrument allows exact, clean, and smooth cut geometries during surgery. The difference in time requirement for surgical procedures using the piezosurgery instrument in comparison with the conventional drill is negligible. Postoperatively, excellent wound healing, with no nerve and soft tissue injuries, is observed. It is apparent that the range of application of piezosurgery is not limited to minor operations. Because of its highly selective and accurate nature, with its cutting effect exclusively targeting hard tissue, its use may be extended to more complex oral surgery cases, as well as to other interdisciplinary problems. (c) 2005 American Association of Oral and Maxillofacial Surgeons.
引用
收藏
页码:1283 / 1287
页数:5
相关论文
共 25 条
[1]   A comparative in vitro study of a magnetostrictive and a piezoelectric ultrasonic scaling instrument [J].
Busslinger, A ;
Lampe, K ;
Beuchat, M ;
Lehmann, B .
JOURNAL OF CLINICAL PERIODONTOLOGY, 2001, 28 (07) :642-649
[2]  
Catuna MC, 1953, ANN DENT, V12, P100
[3]   EFFECT OF INSTRUMENT POWER SETTING DURING ULTRASONIC SCALING UPON TREATMENT OUTCOME [J].
CHAPPLE, ILC ;
WALMSLEY, AD ;
SAXBY, MS ;
MOSCROP, H .
JOURNAL OF PERIODONTOLOGY, 1995, 66 (09) :756-760
[4]  
Drisko C L, 2000, J Periodontol, V71, P1792
[5]   ULTRASONIC WOUND - SOME MICROSCOPIC OBSERVATIONS [J].
EWEN, SJ .
JOURNAL OF PERIODONTOLOGY, 1961, 32 (04) :315-&
[6]   The effect of working parameters on root substance removal using a piezoelectric ultrasonic scaler in vitro [J].
Flemmig, TF ;
Petersilka, GJ ;
Mehl, A ;
Hickel, R ;
Klaiber, B .
JOURNAL OF CLINICAL PERIODONTOLOGY, 1998, 25 (02) :158-163
[7]   CLINICAL-APPLICATIONS OF ULTRASONIC INSTRUMENTATION IN THE SURGICAL REMOVAL OF BONE [J].
HORTON, JE ;
TARPLEY, TM ;
JACOWAY, JR .
ORAL SURGERY ORAL MEDICINE ORAL PATHOLOGY ORAL RADIOLOGY AND ENDODONTICS, 1981, 51 (03) :236-242
[8]   HEALING OF SURGICAL DEFECTS IN ALVEOLAR BONE PRODUCED WITH ULTRASONIC INSTRUMENTATION, CHISEL, AND ROTARY BUR [J].
HORTON, JE ;
TARPLEY, TM ;
WOOD, LD .
ORAL SURGERY ORAL MEDICINE ORAL PATHOLOGY ORAL RADIOLOGY AND ENDODONTICS, 1975, 39 (04) :536-546
[9]  
Ishida S, 2002, CARS 2002: COMPUTER ASSISTED RADIOLOGY AND SURGERY, PROCEEDINGS, P258
[10]  
Kocher T, 1996, Quintessence Int, V27, P259