Gold-silver alloy film based surface plasmon resonance sensor for biomarker detection

被引:23
|
作者
Yi, Ru-meng [1 ]
Zhang, Zhe [1 ]
Liu, Chun-xiu [2 ]
Qi, Zhi-mei [2 ]
机构
[1] Beijing Jiaotong Univ, Sch Comp & Informat Technol, Inst Med Intelligence, Beijing 100044, Peoples R China
[2] Chinese Acad Sci, Inst Elect, State Key Lab Transducer Technol, Beijing 100190, Peoples R China
来源
MATERIALS SCIENCE AND ENGINEERING C-MATERIALS FOR BIOLOGICAL APPLICATIONS | 2020年 / 116卷
基金
中国国家自然科学基金;
关键词
Surface plasmon resonance; Gold-silver alloy film; Biomarker; Sandwich immunoassay; Sensitivity; OVARIAN-CANCER; HIGH-SENSITIVITY; SPR BIOSENSORS; AU; NANOPARTICLES; MOLECULES; PROTEIN; CA125; HE-4;
D O I
10.1016/j.msec.2020.111126
中图分类号
TB3 [工程材料学]; R318.08 [生物材料学];
学科分类号
0805 ; 080501 ; 080502 ;
摘要
In this study, we developed a gold-silver alloy film based surface plasmon resonance (AuAg-SPR) sensor with wavelength interrogation to detect cancer antigen 125 (CA125) using a sandwich immunoassay. We first theoretically simulated the sensitivity of conventional gold film based SPR (Au-SPR) sensor and AuAg-SPR sensor, and conducted a series of experiments to investigate the sensitive characteristics of AuAg-SPR sensor, including the angle and refractive index (RI) sensitivity. We then conducted CA125 detection experiments on these two types of sensors. The results demonstrated that the limit of detection (LOD) of CA125 on the AuAg-SPR sensor was 0.1 U/mL (0.8 ng/mL) based on its direct reaction with an immobilised antibody, which was two orders of magnitude lower than that of the Au-SPR sensor (10 U/mL). The total changes in the resonance wavelength (Lambda lambda(R)) of the former were 1.7-fold those of the latter. The volume fractions of the adsorbates (f(ad)) and effective RIs (n(adlayer)) in each adlayer were then calculated and the effect of the antibody size on the detection results was analysed. The AuAg-SPR sensors had a higher sensitivity than the conventional Au-SPR sensors for detecting CA125 due to their electric field characteristics. Therefore, these will have better application prospects.
引用
收藏
页数:8
相关论文
共 50 条
  • [41] Characterisation of gold surface plasmon resonance sensor substrates
    Sexton, B. A.
    Feltis, B. N.
    Davis, T. J.
    SENSORS AND ACTUATORS A-PHYSICAL, 2008, 141 (02) : 471 - 475
  • [42] Surface plasmon resonance sensor for pesticide detection
    Chegel, VI
    Shirshov, YM
    Piletskaya, EV
    Piletsky, SA
    SENSORS AND ACTUATORS B-CHEMICAL, 1998, 48 (1-3) : 456 - 460
  • [43] Preparation of a sensor substrate using functionalized mesoporous silica on a gold film for surface plasmon resonance (SPR) spectroscopy
    Oh, Seogil
    Moon, Jungwoo
    Kang, Taewook
    Hong, Surin
    Yi, Jongheop
    JOURNAL OF ELECTROCERAMICS, 2006, 17 (2-4) : 999 - 1003
  • [44] Study of interaction of surface plasmon resonance sensor with nano-gold
    Hao Peng
    Wu Yi-Hui
    Zhang Ping
    ACTA PHYSICA SINICA, 2010, 59 (09) : 6532 - 6537
  • [45] Evaluation of PVC@Silver Nanocomposite as Sensor for Low Limit Detection of Cadmium Ion By Surface Plasmon Resonance Based Method
    Ali, Safaa S.
    Ebnalwaled, A. A.
    Mohamed, Gehad G.
    Hafez, M.
    JOURNAL OF INORGANIC AND ORGANOMETALLIC POLYMERS AND MATERIALS, 2024, 34 (09) : 4229 - 4243
  • [46] Surface plasmon resonance sensor based on grapefruit fiber filled with silver nanowires
    Hao Congjing
    Lu Ying
    Fu Xiangyong
    Yao Jianquan
    22ND INTERNATIONAL CONFERENCE ON OPTICAL FIBER SENSORS, PTS 1-3, 2012, 8421
  • [47] Fiber surface enhanced Raman scattering sensor based on patterned biphasic gold-silver nanoalloys
    Liu, Ting
    Xiao, Xiaosheng
    Wang, Peng
    Ji, Linhong
    Yang, Changxi
    CHEMICAL PHYSICS LETTERS, 2012, 553 : 51 - 54
  • [48] Single-Layer-Graphene-Coated and Gold-Film-Based Surface Plasmon Resonance Prism Coupler Sensor for Immunoglobulin G Detection
    Yang, Zhe-Wei
    Pham, Thi-Thu-Hien
    Hsu, Chin-Chi
    Lien, Chi-Hsiang
    Phan, Quoc-Hung
    SENSORS, 2022, 22 (04)
  • [49] Sensitivity Improved Surface Plasmon Resonance Sensor Based on Graphene and Gold Nanorods
    Zeng, Shuwen
    Bergont, Mathieu Sylvain
    Olivier, Aurelien
    Dinh, Xuan-Quyen
    Yu, Xia
    Yong, Ken-Tye
    PROCEEDINGS OF THE 2013 IEEE 5TH INTERNATIONAL NANOELECTRONICS CONFERENCE (INEC), 2013, : 414 - 416
  • [50] Study of Au-Ag alloy film based infrared surface plasmon resonance sensors
    Zhang Zhe
    Liu Qian
    Qi Zhi-Mei
    ACTA PHYSICA SINICA, 2013, 62 (06)