Gold-silver alloy film based surface plasmon resonance sensor for biomarker detection

被引:23
|
作者
Yi, Ru-meng [1 ]
Zhang, Zhe [1 ]
Liu, Chun-xiu [2 ]
Qi, Zhi-mei [2 ]
机构
[1] Beijing Jiaotong Univ, Sch Comp & Informat Technol, Inst Med Intelligence, Beijing 100044, Peoples R China
[2] Chinese Acad Sci, Inst Elect, State Key Lab Transducer Technol, Beijing 100190, Peoples R China
来源
MATERIALS SCIENCE AND ENGINEERING C-MATERIALS FOR BIOLOGICAL APPLICATIONS | 2020年 / 116卷
基金
中国国家自然科学基金;
关键词
Surface plasmon resonance; Gold-silver alloy film; Biomarker; Sandwich immunoassay; Sensitivity; OVARIAN-CANCER; HIGH-SENSITIVITY; SPR BIOSENSORS; AU; NANOPARTICLES; MOLECULES; PROTEIN; CA125; HE-4;
D O I
10.1016/j.msec.2020.111126
中图分类号
TB3 [工程材料学]; R318.08 [生物材料学];
学科分类号
0805 ; 080501 ; 080502 ;
摘要
In this study, we developed a gold-silver alloy film based surface plasmon resonance (AuAg-SPR) sensor with wavelength interrogation to detect cancer antigen 125 (CA125) using a sandwich immunoassay. We first theoretically simulated the sensitivity of conventional gold film based SPR (Au-SPR) sensor and AuAg-SPR sensor, and conducted a series of experiments to investigate the sensitive characteristics of AuAg-SPR sensor, including the angle and refractive index (RI) sensitivity. We then conducted CA125 detection experiments on these two types of sensors. The results demonstrated that the limit of detection (LOD) of CA125 on the AuAg-SPR sensor was 0.1 U/mL (0.8 ng/mL) based on its direct reaction with an immobilised antibody, which was two orders of magnitude lower than that of the Au-SPR sensor (10 U/mL). The total changes in the resonance wavelength (Lambda lambda(R)) of the former were 1.7-fold those of the latter. The volume fractions of the adsorbates (f(ad)) and effective RIs (n(adlayer)) in each adlayer were then calculated and the effect of the antibody size on the detection results was analysed. The AuAg-SPR sensors had a higher sensitivity than the conventional Au-SPR sensors for detecting CA125 due to their electric field characteristics. Therefore, these will have better application prospects.
引用
收藏
页数:8
相关论文
共 50 条
  • [1] Gold-silver alloy film based surface plasmon resonance sensor for biomarker detection
    Yi, Ru-meng
    Zhang, Zhe
    Liu, Chun-xiu
    Qi, Zhi-mei
    ADVANCED SENSOR SYSTEMS AND APPLICATIONS VIII, 2018, 10821
  • [2] Gold-Silver Alloy Film Based Spectral Surface Plasmon Resonance Imaging Sensor with High Sensitivity
    Liang Shuang
    Gao Ran
    Zhang Mengying
    Xue Ning
    Qi Zhimei
    ACTA PHYSICO-CHIMICA SINICA, 2019, 35 (06) : 630 - 636
  • [3] Predicting the Surface Plasmon Resonance Wavelength of Gold-Silver Alloy Nanoparticles
    Verbruggen, Sammy W.
    Keulemans, Maarten
    Martens, Johan A.
    Lenaerts, Silvia
    JOURNAL OF PHYSICAL CHEMISTRY C, 2013, 117 (37) : 19142 - 19145
  • [4] Bimetallic silver-gold film waveguide surface plasmon resonance sensor
    Ong, Biow Hiem
    Yuan, Xiaocong
    Tjin, Swee Chuan
    FIBER AND INTEGRATED OPTICS, 2007, 26 (04) : 229 - 240
  • [5] A Sensitive and Stable Surface Plasmon Resonance Sensor Based on Monolayer Protected Silver Film
    Wang, Guiqiang
    Wang, Chunnan
    Yang, Rui
    Liu, Wenlan
    Sun, Shuqing
    SENSORS, 2017, 17 (12)
  • [6] Bimetallic silver-gold film waveguide surface plasmon resonance sensor
    Ong, Biow Hiem
    Yuan, Xiaocong
    Tjin, Swee Chuan
    INTEGRATED OPTICS: DEVICES, MATERIALS, AND TECHNOLOGIES X, 2006, 6123
  • [7] Preparation and Characterization of Nanoporous Gold Film Based Surface Plasmon Resonance Sensor
    Wang Li
    Wan Xiumei
    Gao Ran
    Lu Danfeng
    Qi Zhimei
    ACTA OPTICA SINICA, 2018, 38 (02)
  • [8] Sensitivity Enhancement for Surface Plasmon Resonance Imaging Biosensor by Utilizing Gold-Silver Bimetallic Film Configuration
    Xia, Liangping
    Yin, Shaoyun
    Gao, Hongtao
    Deng, Qiling
    Du, Chunlei
    PLASMONICS, 2011, 6 (02) : 245 - 250
  • [9] Surface Plasmon Resonance (SPR) Sensor for Cancer Biomarker Detection
    Das, Sreyashi
    Devireddy, Ram
    Gartia, Manas Ranjan
    BIOSENSORS-BASEL, 2023, 13 (03):
  • [10] SURFACE PLASMON RESONANCE SENSOR OF SILVER FILM BASED ON KRETCHMANN CONFIGURATION
    Ley, Hood-Hong
    Yahaya, Asiah
    Munajat, Yusof
    JURNAL TEKNOLOGI, 2015, 76 (13): : 95 - 99