Reconstruction of large cranial defects with poly-methyl-methacrylate (PMMA) using a rapid prototyping model and a new technique for intraoperative implant modeling

被引:35
|
作者
Unterhofer, Claudia [1 ]
Wipplinger, Christoph [1 ]
Verius, Michael [2 ]
Recheis, Wolfgang [2 ]
Thome, Claudius [1 ]
Ortler, Martin [1 ]
机构
[1] Innsbruck Med Univ, Clin Dept Neurosurg, Anichstr 35, A-6020 Innsbruck, Austria
[2] Innsbruck Med Univ, Clin Dept Radiol, Innsbruck, Austria
关键词
Cranioplasty; Poly-methyl-methacrylate (PMMA); Rapid prototyping; Stereolithography; CT-GUIDED STEREOLITHOGRAPHY; TITANIUM CRANIOPLASTY; CRANIOFACIAL SURGERY; PROSTHESES; DESIGN; SKULL; BONE;
D O I
10.1016/j.pjnns.2017.02.007
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
Background: Reconstruction of large cranial defects after craniectomy can be accomplished by free-hand poly-methyl-methacrylate (PMMA) or industrially manufactured implants. The free-hand technique often does not achieve satisfactory cosmetic results but is inexpensive. In an attempt to combine the accuracy of specifically manufactured implants with low cost of PMMA. Methods: Forty-six consecutive patients with large skull defects after trauma or infection were retrospectively analyzed. The defects were reconstructed using computer-aided design/ computer-aided manufacturing (CAD/CAM) techniques. The computer file was imported into a rapid prototyping (RP) machine to produce an acrylonitrile-butadienestyrene model (ABS) of the patient's bony head. The gas-sterilized model was used as a template for the intraoperative modeling of the PMMA cranioplasty. Thus, not the PMMA implant was generated by CAD/CAM technique but the model of the patients head to easily form a well-fitting implant. Cosmetic outcome was rated on a six-tiered scale by the patients after a minimum follow-up of three months. Results: The mean size of the defect was 74.36 cm(2). The implants fitted well in all patients. Seven patients had a postoperative complication and underwent reoperation. Mean followup period was 41 months (range 2-91 months). Results were excellent in 42, good in three and not satisfactory in one patient. Costs per implant were approximately 550 Euros. Conclusion: PMMA implants fabricated in-house by direct molding using a bio-model of the patients bony head are easily produced, fit properly and are inexpensive compared to cranial implants fabricated with other RP or milling techniques. (C) 2017 Polish Neurological Society. Published by Elsevier Sp. z o.o. All rights reserved.
引用
收藏
页码:214 / 220
页数:7
相关论文
empty
未找到相关数据