Characteristics of T(0,1) Guided-Wave Point-Focusing Electromagnetic Acoustic Transducer for Pipe Inspection

被引:17
作者
Huang, Songling [1 ]
Sun, Hongyu [1 ]
Shen, Gongtian [2 ]
Wang, Baoxuan [2 ]
Wang, Qing [3 ]
Zou, Jun [1 ]
Wang, Shen [1 ]
机构
[1] Tsinghua Univ, State Key Lab Power Syst, Dept Elect Engn, Beijing 100084, Peoples R China
[2] China Special Equipment Inspect & Res Inst, Beijing 100029, Peoples R China
[3] Univ Durham, Dept Engn, Durham DH1 3LE, England
基金
中国国家自然科学基金; 国家重点研发计划;
关键词
T(0; 1) guided-wave; point-focusing; periodic permanent magnet; focal length; defect width; HOLLOW CYLINDERS; EMAT; PROPAGATION; EXCITATION; CORROSION; SIGNALS; DESIGN; PLATES;
D O I
10.1109/JSEN.2019.2958953
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Electromagnetic acoustic transducers (EMATs) are widely used in the field of non-destructive testing (NDT) and non-destructive evaluation (NDE) due to their advantages of non-contact and applicability in complex environments. However, their low energy-conversion efficiency restricts their application in industrial testing. This work proposes a newly designed focusing EMAT based on the T(0, 1)-wave in a pipe to improve the energy conversion efficiency of EMATs. The focal length and defect width are investigated in this paper, and the advantages of the newly designed point-focusing transducer are shown in comparison with traditional unfocused transducers. Results show that the newly designed pipe focusing EMAT can increase the intensity of the defect reflection wave by around 60%, and the reflected wave intensity can be enhanced by 70% in the experiment when compared to the unfocused one.
引用
收藏
页码:2895 / 2903
页数:9
相关论文
共 35 条
[1]   Circumferential guided wave EMAT system for pipeline screening using shear horizontal ultrasound [J].
Clough, Matthew ;
Fleming, Matthew ;
Dixon, Steve .
NDT & E INTERNATIONAL, 2017, 86 :20-27
[2]   Development of circuits for excitation and reception in ultrasonic transducers for generation of guided waves in hollow cylinders for fouling detection [J].
da Silva, Jaidilson Jo ;
Wanzeller, Miguel Goncalves ;
Farias, Paulo de Almeida ;
da Rocha Neto, Jose Sergio .
IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 2008, 57 (06) :1149-1153
[3]   A hybrid finite element model for simulation of electromagnetic acoustic transducer (EMAT) based plate waves [J].
Dhayalan, R. ;
Balasubramaniam, Krishnan .
NDT & E INTERNATIONAL, 2010, 43 (06) :519-526
[4]   Liver Fibrosis in Viral Hepatitis: Noninvasive Assessment with Acoustic Radiation Force Impulse Imaging versus Transient Elastography [J].
Friedrich-Rust, Mireen ;
Wunder, Katrin ;
Kriener, Susanne ;
Sotoudeh, Fariba ;
Richter, Swantje ;
Bojunga, Joerg ;
Herrmann, Eva ;
Poynard, Thierry ;
Dietrich, Christoph F. ;
Vermehren, Johannes ;
Zeuzem, Stefan ;
Sarrazin, Christoph .
RADIOLOGY, 2009, 252 (02) :595-604
[7]   Wave structure analysis of guided waves in a bar with an arbitrary cross-section [J].
Hayashi, T ;
Tamayama, C ;
Murase, M .
ULTRASONICS, 2006, 44 (01) :17-24
[8]   Unidirectional focusing of horizontally polarized shear elastic waves electromagnetic acoustic transducers for plate inspection [J].
Huang, S. L. ;
Sun, H. Y. ;
Wang, Q. ;
Wang, S. ;
Zhao, W. .
JOURNAL OF APPLIED PHYSICS, 2019, 125 (16)
[9]   An Opening Profile Recognition Method for Magnetic Flux Leakage Signals of Defect [J].
Huang, Songling ;
Peng, Lisha ;
Wang, Qing ;
Wang, Shen ;
Zhao, Wei .
IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 2019, 68 (06) :2229-2236
[10]   Improved finite element method for EMAT analysis and design [J].
Jafari-Shapoorabadi, R ;
Konrad, A ;
Sinclair, AN .
IEEE TRANSACTIONS ON MAGNETICS, 2001, 37 (04) :2821-2823