Reconsideration of EMI Phenomenon in Active Implantable Medical Devices in the Age of MR Conditional Devices

被引:0
|
作者
Toyoshima, Takeshi [1 ]
机构
[1] USCI Holdings Inc, CRDM Business Unit, Tokyo, Japan
来源
2014 INTERNATIONAL SYMPOSIUM ON ELECTROMAGNETIC COMPATIBILITY, TOKYO (EMC'14/TOKYO) | 2014年
关键词
AIMD; MRI; static magnet field; magnet field gradient; rf pulses; PACEMAKERS;
D O I
暂无
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Until recently, the presence of an AIMD has beencontraindication to MRI because of the potential adverse effects of MRI on AIMDs. However, all of AIMD manufacturers have released "MR Conditional" devices recently. These devices have been demonstrated to pose no known hazards in a specified MRI environment with specified conditions of use. Therefore, it is quite important to understand what kind of clinical phenomena would take place if an accidental scan of a conventional device was performed. If the MRI scanning of a patient with non MR compatible AIMD is needed from special medical requirement, intensive monitoring of heart activity during the scanning and repetitive threshold measurements after the scanning will be essential.
引用
收藏
页码:234 / 236
页数:3
相关论文
共 50 条
  • [11] MR Conditionality of Abandoned Leads from Active Implantable Medical Devices at 1.5T
    Wang, Yu
    Guo, Ran
    Hu, Wei
    Jiang, Jay
    Kainz, Wolfgang
    Chen, Ji
    2021 43RD ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE & BIOLOGY SOCIETY (EMBC), 2021, : 7412 - 7415
  • [12] EMI problems for medical devices
    Rao, S
    Sathyanarayanan, A
    Nandwani, UK
    PROCEEDING OF THE INTERNATIONAL CONFERENCE ON ELECTROMAGNETIC INTERFERENCE AND COMPATIBILITY '99, 1999, : 21 - 24
  • [13] Beware of MR Conditional and MR Compatible Devices
    Gach, H. M.
    Mazur, T. R.
    MEDICAL PHYSICS, 2024, 51 (10) : 7853 - 7853
  • [14] Characteristics and progress of research on the reliability of active implantable medical devices
    Wang W.
    Li B.
    Li L.
    Qinghua Daxue Xuebao/Journal of Tsinghua University, 2023, 63 (05): : 792 - 801
  • [15] Molecular Sieves as Getter Material for Active Implantable Medical Devices
    Kohler, F.
    Porro, Y.
    Stieglitz, T.
    Schuettler, M.
    BIOMEDICAL ENGINEERING-BIOMEDIZINISCHE TECHNIK, 2012, 57 : 854 - 854
  • [16] Key Considerations for Power Management in Active Implantable Medical Devices
    Haci, Dorian
    Liu, Yan
    Ghoreishizadeh, Sara S.
    Constandinou, Timothy G.
    2020 IEEE 11TH LATIN AMERICAN SYMPOSIUM ON CIRCUITS & SYSTEMS (LASCAS), 2020,
  • [17] Impact of Electromagnetic Fields in Transport on Active Implantable Medical Devices
    Mydlova, Jana
    Galova, Ivana
    Benova, Mariana
    13TH INTERNATIONAL SCIENTIFIC CONFERENCE ON SUSTAINABLE, MODERN AND SAFE TRANSPORT (TRANSCOM 2019), 2019, 40 : 1497 - 1503
  • [18] Implantable RF Medical Devices
    Chow, Eric Y.
    Morris, Milton M.
    Irazoqui, Pedro P.
    IEEE MICROWAVE MAGAZINE, 2013, 14 (04) : 64 - 73
  • [19] Testing implantable medical devices
    Cortner, JM
    EE-EVALUATION ENGINEERING, 2004, 43 (06): : 38 - +
  • [20] Nanocoatings on implantable medical devices
    Arsiwala, Ammar M.
    Raval, Ankur J.
    Patravale, Vandana B.
    PHARMACEUTICAL PATENT ANALYST, 2013, 2 (04) : 499 - 512