The Value of Digital Volume Tomography in Assessing the Position of Cochlear Implant Arrays in Temporal Bone Specimens

被引:34
作者
Kurzweg, Thiemo [1 ]
Dalchow, Carsten V. [2 ]
Bremke, Martin [3 ]
Majdani, Omid [4 ]
Kureck, Ingo [5 ]
Knecht, Reinald [1 ]
Werner, Jochen A. [3 ]
Teymoortash, Afshin [3 ]
机构
[1] Univ Med Ctr Hamburg Eppendorf UKE, Dept Otolaryngol Head & Neck Surg, Hamburg, Germany
[2] Pk Klin Weissensee, Dept Otolaryngol Head & Neck Surg, Berlin, Germany
[3] Univ Marburg, Dept Otolaryngol, D-35037 Marburg, Germany
[4] Hannover Med Sch, Dept Otolaryngol, D-3000 Hannover, Germany
[5] Univ Marburg, Dept Neuroradiol, D-35037 Marburg, Germany
关键词
MULTIDETECTOR COMPUTED-TOMOGRAPHY; ELECTRODE ARRAY; SCALAR LOCALIZATION; QUALITY-CONTROL; DENTAL USE; CT; MENINGITIS; INSERTION; SURGERY; CONTOUR;
D O I
10.1097/AUD.0b013e3181d3d6b6
中图分类号
R36 [病理学]; R76 [耳鼻咽喉科学];
学科分类号
100104 ; 100213 ;
摘要
Objectives: Radiological evaluation of the position of cochlear implant (CI) devices is an upcoming method for quality control after CI surgery. First, results of imaging of the middle and inner ear with digital volume tomography (DVT) show considerable advantages such as exceptional image quality, thin slice thickness, and low radiation dose. The aim of this study was to evaluate whether DVT is an appropriate method for postoperative imaging of CI patients and to identify the exact position of the implant array within the cochlear by multiple measurements. Design: Thirteen formalin-fixed temporal bone specimens were implanted with a CI array and scanned in DVT. To determine the exact electrode position, these specimens were ground and stained for microscopic measurements. The measurements on grindings acted as a referee and were compared with the measurements in DVT scans. The statistical analysis between the two measurement protocols was performed using the Bland-Altman method. Results: Best achievable agreement between DVT scans and histological reference was shown. Mean differences between DVT and grindings from -1.55 to -65.40 mu m were calculated. All means are within the region of accuracy. General positioning of the implant into the cochlea could be verified in all specimens. The exact position of the implanted array within the cochlear scalae could be recognized correctly in 11 of 13 cases in DVT. It was possible to identify shiftings between the tympanic and vestibular scalae in all cases. Conclusion: DVT seems to be a convenient technique for postoperative position control after cochlear implantation.
引用
收藏
页码:413 / 419
页数:7
相关论文
共 28 条
[1]   Development of a compact computed tomographic apparatus for dental use [J].
Arai, Y ;
Tammisalo, E ;
Iwai, K ;
Hashimoto, K ;
Shinoda, K .
DENTOMAXILLOFACIAL RADIOLOGY, 1999, 28 (04) :245-248
[2]   Meningitis following cochlear implantation:: Pathomechanisms, clinical symptoms, conservative and surgical treatments [J].
Arnold, W ;
Bredberg, G ;
Gstöttner, W ;
Helms, J ;
Hildmann, H ;
Kiratzidis, T ;
Müller, J ;
Ramsden, RT ;
Roland, P ;
Walterspiel, JN .
ORL-JOURNAL FOR OTO-RHINO-LARYNGOLOGY AND ITS RELATED SPECIALTIES, 2002, 64 (06) :382-389
[3]   Quality control after cochlear implant surgery by means of rotational tomography [J].
Aschendorff, A ;
Kubalek, T ;
Turowski, B ;
Zanella, T ;
Hochmuth, T ;
Schumacher, T ;
Klenzner, T ;
Laszig, R .
OTOLOGY & NEUROTOLOGY, 2005, 26 (01) :34-37
[4]   Imaging procedures in cochlear implant patients - Evaluation of different radiological techniques [J].
Aschendorff, A ;
Kubalek, R ;
Hochmuth, A ;
Bink, A ;
Kurtz, C ;
Lohnstein, P ;
Klenzner, T ;
Laszig, R .
ACTA OTO-LARYNGOLOGICA, 2004, 124 :46-49
[5]   Quality control after insertion of the nucleus contour and contour advance electrode in adults [J].
Aschendorff, Antje ;
Kromeier, Jan ;
Klenzner, Thomas ;
Laszig, Roland .
EAR AND HEARING, 2007, 28 (02) :75S-79S
[6]   Flat-panel volume computed tomography for cochlear implant electrode array examination in isolated temporal bone specimens [J].
Bartling, Soenke H. ;
Gupta, Rajiv ;
Torkos, Attila ;
Dullin, Christian ;
Eckhardt, Grabbe ;
Lenarz, Thomas ;
Becker, Hartmut ;
Stöver, Timo .
OTOLOGY & NEUROTOLOGY, 2006, 27 (04) :491-498
[7]   Bacterial meningitis among children with cochlear implants beyond 24 months after implantation [J].
Biernath, KR ;
Reefhuis, J ;
Whitney, CG ;
Mann, EA ;
Costa, P ;
Eichwald, J ;
Boyle, C .
PEDIATRICS, 2006, 117 (02) :284-289
[8]   Applying the right statistics: analyses of measurement studies [J].
Bland, JM ;
Altman, DG .
ULTRASOUND IN OBSTETRICS & GYNECOLOGY, 2003, 22 (01) :85-93
[9]  
Bland JM, 1999, STAT METHODS MED RES, V8, P135, DOI 10.1177/096228029900800204
[10]   MEDICAL OR SURGICAL COMPLICATIONS RELATED TO THE NUCLEUS MULTICHANNEL COCHLEAR IMPLANT [J].
COHEN, NL ;
HOFFMAN, RA ;
STROSCHEIN, M .
ANNALS OF OTOLOGY RHINOLOGY AND LARYNGOLOGY, 1988, 97 (05) :8-13