Calibrating stereo-digital image correlation system using synthetic speckle-pattern calibration target

被引:16
作者
Chen, Bin [1 ]
Liu, Haibo [2 ]
Pan, Bing [1 ,3 ]
机构
[1] Beihang Univ, Sch Aeronaut Sci & Engn, Inst Solid Mech, Beijing 100191, Peoples R China
[2] Natl Univ Def Technol, Coll Aerosp Sci & Engn, Changsha 410073, Peoples R China
[3] Beihang Univ, Beijing Adv Discipline Ctr Unmanned Aircraft Syst, Beijing 100191, Peoples R China
基金
中国国家自然科学基金;
关键词
stereo calibration; speckle-pattern calibration target; stereo-digital image correlation; inaccurate target; CAMERA;
D O I
10.1088/1361-6501/ab8dfb
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
We describe an alternative stereo calibration method for stereo-digital image correlation (stereo-DIC) using computer-simulated speckle-pattern calibration targets and a DIC-based control points matching technique. The present work refines and extends the recently proposed camera calibration method to stereo calibration, which is an essential part of stereo-DIC measurement. In the proposed calibration method, the calibration target is generated by displaying a synthetic speckle pattern on a commercial tablet. On the simulated speckle pattern, a group of control points is specified with flexible location and number, which is further precisely matched to the captured calibration images using the well-developed subset-based DIC algorithm. These precisely matched control points are subsequently used to calibrate the intrinsic and extrinsic parameters of the stereo-DIC system with stereo calibration algorithm. For better accuracy, the error in the manufacture of the calibration target is also considered and compensated. As a flexible number of control point matches are registered with high accuracy and strong robustness, the presented stereo calibration method using synthetic speckle pattern calibration target offers higher calibration accuracy than that based on a calibration target with a limited number of designated features, such as checkerboard target and circular point target. After being demonstrated by a set of simulated calibration tests, the proposed stereo calibration method was applied to calibrate a real stereo-DIC system, which was then used to measure 3D full-field shapes and displacements. The results confirm the effectiveness and accuracy of the proposed stereo calibration method for stereo-DIC applications.
引用
收藏
页数:12
相关论文
共 28 条
[1]   Camera calibration using synthetic random speckle pattern and digital image correlation [J].
Chen, Bin ;
Pan, Bing .
OPTICS AND LASERS IN ENGINEERING, 2020, 126
[2]  
Chen D., 2005, The 13th International Conference in Central Europe on Computer Graphics, Visualization and Computer Vision, P97
[3]   A combined temporal tracking and stereo-correlation technique for accurate measurement of 3D displacements: application to sheet metal forming [J].
Garcia, D ;
Orteu, JJ ;
Penazzi, L .
JOURNAL OF MATERIALS PROCESSING TECHNOLOGY, 2002, 125 :736-742
[4]   Stereo-camera calibration for large-scale DIC measurements with active phase targets and planar mirrors [J].
Genovese, Katia ;
Chi, Yuxi ;
Pan, Bing .
OPTICS EXPRESS, 2019, 27 (06) :9040-9053
[5]  
Hartley R.I., 2004, Multiple View Geometry in Computer Vision, Vsecond, P32
[6]   Triangulation [J].
Hartley, RI ;
Sturm, P .
COMPUTER VISION AND IMAGE UNDERSTANDING, 1997, 68 (02) :146-157
[7]   A four-step camera calibration procedure with implicit image correction [J].
Heikkila, J ;
Silven, O .
1997 IEEE COMPUTER SOCIETY CONFERENCE ON COMPUTER VISION AND PATTERN RECOGNITION, PROCEEDINGS, 1997, :1106-1112
[8]   A flexible and easy-to-implement single-camera microscopic 3D digital image correlation technique [J].
Li, Chenzhuo ;
Dong, Bo ;
Pan, Bing .
MEASUREMENT SCIENCE AND TECHNOLOGY, 2019, 30 (08)
[9]   Distinctive image features from scale-invariant keypoints [J].
Lowe, DG .
INTERNATIONAL JOURNAL OF COMPUTER VISION, 2004, 60 (02) :91-110
[10]   Advanced geometric camera calibration for machine vision [J].
Minh Vo ;
Wang, Zhaoyang ;
Luu, Long ;
Ma, Jun .
OPTICAL ENGINEERING, 2011, 50 (11)