Image registration based on the structure tensor of the local phase

被引:3
|
作者
Li, Zhang [1 ]
van Vliet, Lucas J. [1 ]
Stoker, Jaap [2 ]
Vos, Frans M. [1 ,2 ]
机构
[1] Delft Univ Technol, Dept Imaging Phys, Quantitat Imaging Grp, NL-2628 CJ Delft, Netherlands
[2] Acad Med Ctr Amsterdam, Dept Radiol, NL-1105 AZ Amsterdam, Netherlands
来源
MEDICAL IMAGING 2015: IMAGE PROCESSING | 2015年 / 9413卷
关键词
monogenic signal; tensor reorientation; structure-based registration;
D O I
10.1117/12.2081840
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
Image registration of medical images in the presence of large intra-image signal fluctuations is a challenging task. Our paper addresses this problem by introducing a new concept based on the structure tensor of the local phase. The local phase is calculated from the monogenic signal representation of the images. The local phase image is hardly affected by unwanted signal fluctuations due to a space-variant background and a space-variant contrast. The boundary structure tensor combines the responses of edges and corners/junctions in one tensor, which has several advantages, compared to other structure tensors. We reorient the structure tensor during the registration by means of the finite-strain technique. The structure tensor is only calculated once during a preprocessing step. The results demonstrate that the proposed method effectively deals with large signal fluctuations. It performs significantly better than competing techniques.
引用
收藏
页数:6
相关论文
共 50 条
  • [1] Using the Local Phase of the Magnitude of the Local Structure Tensor for Image Registration
    Eklund, Anders
    Forsberg, Daniel
    Andersson, Mats
    Knutsson, Hans
    IMAGE ANALYSIS: 17TH SCANDINAVIAN CONFERENCE, SCIA 2011, 2011, 6688 : 414 - 423
  • [2] Multimodal image registration with joint structure tensor and local entropy
    Jingya Zhang
    Jiajun Wang
    Xiuying Wang
    Dagan Feng
    International Journal of Computer Assisted Radiology and Surgery, 2015, 10 : 1765 - 1775
  • [3] Multimodal image registration with joint structure tensor and local entropy
    Zhang, Jingya
    Wang, Jiajun
    Wang, Xiuying
    Feng, Dagan
    INTERNATIONAL JOURNAL OF COMPUTER ASSISTED RADIOLOGY AND SURGERY, 2015, 10 (11) : 1765 - 1775
  • [4] Nonrigid registration of medical image based on adaptive local structure tensor and normalized mutual information
    Yang, Tiejun
    Tang, Qi
    Li, Lei
    Song, Jikun
    Zhu, Chunhua
    Tang, Lu
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2019, 20 (06): : 99 - 110
  • [5] Image Registration Based on Autocorrelation of Local Structure
    Li, Zhang
    Mahapatra, Dwarikanath
    Tielbeek, Jeroen A. W.
    Stoker, Jaap
    van Vliet, Lucas J.
    Vos, Frans M.
    IEEE TRANSACTIONS ON MEDICAL IMAGING, 2016, 35 (01) : 63 - 75
  • [6] Structure tensor-based SIFT algorithm for SAR image registration
    Divya, S., V
    Paul, Sourabh
    Pati, Umesh Chandra
    IET IMAGE PROCESSING, 2020, 14 (05) : 929 - 938
  • [7] Novel Image Registration Method Based on Local Structure Constraints
    Li, Aixia
    Cheng, Xiaojun
    Guan, Haiyan
    Feng, Tiantian
    Guan, Zequn
    IEEE GEOSCIENCE AND REMOTE SENSING LETTERS, 2014, 11 (09) : 1584 - 1588
  • [8] Retinal image Automatic registration based on local bifurcation structure
    Zhang, Kun
    Zhang, Encai
    Li, Jichun
    Chen, Guannan
    2016 9TH INTERNATIONAL CONGRESS ON IMAGE AND SIGNAL PROCESSING, BIOMEDICAL ENGINEERING AND INFORMATICS (CISP-BMEI 2016), 2016, : 1418 - 1422
  • [9] Tensor scale-based image registration
    Saha, PK
    Zhang, H
    Udupa, JK
    Gee, JC
    MEDICAL IMAGING 2003: IMAGE PROCESSING, PTS 1-3, 2003, 5032 : 314 - 324
  • [10] MULTI-SENSOR IMAGE REGISTRATION BASED-ON LOCAL PHASE COHERENCE
    Hassen, Rania
    Wang, Zhou
    Salama, Magdy
    2009 16TH IEEE INTERNATIONAL CONFERENCE ON IMAGE PROCESSING, VOLS 1-6, 2009, : 181 - 184