Percutaneous instrumentation of the cervical and cervico-thoracic spine using pedicle screws: preliminary clinical results and analysis of accuracy

被引:25
|
作者
Schaefer, Christian [1 ]
Begemann, Phillip [2 ]
Fuhrhop, Ina [1 ]
Schroeder, Malte [1 ]
Viezens, Lennart [1 ]
Wiesner, Lothar [1 ]
Hansen-Algenstaedt, Nils [1 ]
机构
[1] Univ Med Ctr Hamburg Eppendorf, Spine Ctr, Orthopaed Spine Surg, D-20246 Hamburg, Germany
[2] Univ Med Ctr Hamburg Eppendorf, Dept Diagnost & Intervent Radiol, D-20246 Hamburg, Germany
关键词
CPS; Percutaneous; Cervical; Instrumentation; Fluoroscopy; Minimally invasive; EXTRACRANIAL VERTEBRAL ARTERY; LUMBAR INTERBODY FUSION; COMPUTED-TOMOGRAPHY; BIOMECHANICAL ANALYSIS; NONTRAUMATIC LESIONS; SURGICAL TECHNIQUE; INTERNAL-FIXATION; PLACEMENT; COMPLICATIONS; INSERTION;
D O I
10.1007/s00586-011-1775-9
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
The pedicle screw instrumentation represents the most rigid construct of the cervical and cervicothoracic spine and in spite of the risks to neurovascular structures clinical relevant complications do not occur frequently. The steep angles of the cervical pedicles result in a wide surgical exposure with extensive muscular trauma. The objective of this study was the evaluation of the accuracy of cervical pedicle screw insertion through a minimally invasive technique to reduce access-related muscular trauma. Therefore, percutaneous transpedicular instrumentation of the cervical and cervicothoracic spine was performed in 15 patients using fluoroscopy. All instrumentations from C2 to Th4 were inserted bilaterally through 2 to 3-cm skin and fascia incisions even in multilevel procedures and the rods were placed by blunt insertion through the incision. Thin-cut CT scan was used postoperatively to analyze pedicle violations. 76.4% of 72 screws were placed accurately. Most pedicle perforations were seen laterally towards the vertebral artery. Critical breaches > 2 mm or narrowing of the transversal foramen occurred in 12.5% of screws; however, no revision surgery for screw displacement was needed in the absence of clinical symptoms. No conversion from percutaneous to open surgery was necessary. It was concluded that percutaneous transpedicular instrumentation of the cervical spine is a surgically demanding technique and should be reserved for experienced spine surgeons. The indications are limited to instrumentation-only procedures or in combination with anterior treatment, but with the potential to minimize access-related morbidity.
引用
收藏
页码:977 / 985
页数:9
相关论文
共 16 条
  • [1] Percutaneous instrumentation of the cervical and cervico-thoracic spine using pedicle screws: preliminary clinical results and analysis of accuracy
    Christian Schaefer
    Phillip Begemann
    Ina Fuhrhop
    Malte Schroeder
    Lennart Viezens
    Lothar Wiesner
    Nils Hansen-Algenstaedt
    European Spine Journal, 2011, 20 : 977 - 985
  • [2] Accuracy and Safety of Fluoroscopic Guided Percutaneous Pedicle Screws in Thoracic and Lumbosacral Spine
    Hansen-Algenstaedt, Nils
    Chiu, Chee Kidd
    Chan, Chris Yin Wei
    Lee, Chee Kean
    Schaefer, Christian
    Kwan, Mun Keong
    SPINE, 2015, 40 (17) : E954 - E963
  • [3] Accuracy of percutaneous pedicle screws for thoracic and lumbar spine fractures: a prospective trial
    Heintel, Timo Michael
    Berglehner, Andreas
    Meffert, Rainer
    EUROPEAN SPINE JOURNAL, 2013, 22 (03) : 495 - 502
  • [4] Accuracy of percutaneous pedicle screws for thoracic and lumbar spine fractures compared with open technique
    Paredes, Igor
    Panero, Irene
    Cepeda, Santiago
    Castano-Leon, Ana M.
    Jimenez-Roldan, Luis
    Perez-Nunez, Angel
    Alen, Jose A.
    Lagares, Alfonso
    JOURNAL OF NEUROSURGICAL SCIENCES, 2021, 65 (01) : 38 - 46
  • [5] The accuracy and safety of fluoroscopic-guided percutaneous pedicle screws in the thoracic and lumbosacral spine in the Asian population: A CT scan analysis of 1002 screws
    Chiu, Chee Kidd
    Chan, Chris Yin Wei
    Kwan, Mun Keong
    JOURNAL OF ORTHOPAEDIC SURGERY, 2017, 25 (02)
  • [6] Accuracy of Free-Hand Pedicle Screws in the Thoracic and Lumbar Spine: Analysis of 6816 Consecutive Screws
    Parker, Scott L.
    McGirt, Matthew J.
    Farber, S. Harrison
    Amin, Anubhav G.
    Rick, Anne-Marie
    Suk, Ian
    Bydon, Ali
    Sciubba, Daniel M.
    Wolinsky, Jean-Paul
    Gokaslan, Ziya L.
    Witham, Timothy F.
    NEUROSURGERY, 2011, 68 (01) : 170 - 178
  • [7] Percutaneous Placement of Pedicle Screws in the Lumbar Spine Using a Bone Mounted Miniature Robotic System First Experiences and Accuracy of Screw Placement
    Pechlivanis, Ioannis
    Kiriyanthan, George
    Engelhardt, Martin
    Scholz, Martin
    Luecke, Sebastian
    Harders, Albrecht
    Schmieder, Kirsten
    SPINE, 2009, 34 (04) : 392 - 398
  • [8] Percutaneous versus open pedicle screw instrumentation in treatment of thoracic and lumbar spine fractures A systematic review and meta-analysis
    Tian, Feng
    Tu, Lai-Yong
    Gu, Wen-Fei
    Zhang, En-Feng
    Wang, Zhen-Bin
    Chu, Ge
    Ka, Haer
    Zhao, Jiang
    MEDICINE, 2018, 97 (41)
  • [9] Accuracy of Pedicle Screw Placement in the Thoracic and Lumbosacral Spine Using a Conventional Intraoperative Fluoroscopy-Guided Technique: A National Neurosurgical Education and Training Center Analysis of 1236 Consecutive Screws
    Nevzati, Edin
    Marbacher, Serge
    Soleman, Jehuda
    Perrig, Wolfgang Nicolas
    Diepers, Michael
    Khamis, Abdussalam
    Fandino, Javier
    WORLD NEUROSURGERY, 2014, 82 (05) : 866 - U540
  • [10] Accuracy of the Free-hand Placement of Pedicle Screws in the Lumbosacral Spine Using a Universal Entry Point Clinical Validation
    Miekisiak, Grzegorz
    Kornas, Piotr
    Lekan, Maciej
    Dacko, Wladyslaw
    Latka, Dariusz
    Kaczmarczyk, Jacek