关键词
Stroke; Validity; Reliability; Sitting position; Posture; TEST-RETEST RELIABILITY; BALANCE ASSESSMENT; POSTURAL CONTROL; REHABILITATION; PERFORMANCE; RECOVERY; VALIDATION; STRATEGIES; PREDICTOR; ADULTS;
D O I
10.1016/j.heliyon.2022.e10891
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
Objective: The objective of this study was to assess, for individuals with hemiparesis after a stroke in subacute phase, the validity and reliability of center of pressure (CoP) parameters measured during sitting balance on an unstable support.Materials and methods: Thirty-two individuals after stroke were included in this observational study for validity and reliability (mean age: 64.34 +/- 9.30y, 23 men, mean post-stroke duration: 55.64 +/- 27days). Intra-Class Correlation (ICC) and Bland Altman plot assessed intra-rater reliability and inter-rater reliability of CoP param-eters during unstable sitting balance test (anteroposterior or mediolateral imbalance). Validity was established by correlating CoP parameters with the Modified Functional Reach Test, trunk strength, Balance Assessment in Sitting and Standing and Timed Up and Go tests.Results: The findings highlighted significant correlations between CoP parameters and trunk strength for ante-roposterior seated destabilization. Good to excellent intra and inter-rater reliability (0.87 <= ICC <= 0.95) was observed for all CoP length parameters and CoP mean velocity in both mediolateral and anteroposterior imbal-ance conditions. CoP parameters for mediolateral unstable sitting condition were more reliable than for ante-roposterior instability.Conclusion: Trunk control assessment during unstable sitting position on a seesaw is a reliable test for assessing trunk control ability in individuals after a stroke. CoP length and mean velocity are found to be the best parameters.
引用
收藏
页数:8
相关论文
共 46 条
  • [1] Reliability, validity, and responsiveness of three scales for measuring balance in patients with chronic stroke
    Alghadir, Ahmad H.
    Al-Eisa, Einas S.
    Anwer, Shahnawaz
    Sarkar, Bibhuti
    [J]. BMC NEUROLOGY, 2018, 18
  • [2] Reliability and Repetition Effect of the Center of Pressure and Kinematics Parameters That Characterize Trunk Postural Control During Unstable Sitting Test
    Barbado, David
    Moreside, Janice
    Vera-Garcia, Francisco J.
    [J]. PM&R, 2017, 9 (03) : 219 - 230
  • [3] Agreed definitions and a shared vision for new standards in stroke recovery research: The Stroke Recovery and Rehabilitation Roundtable taskforce
    Bernhardt, Julie
    Hayward, Kathryn S.
    Kwakkel, Gert
    Ward, Nick S.
    Wolf, Steven L.
    Borschmann, Karen
    Krakauer, John W.
    Boyd, Lara A.
    Carmichael, S. Thomas
    Corbett, Dale
    Cramer, Steven C.
    [J]. INTERNATIONAL JOURNAL OF STROKE, 2017, 12 (05) : 444 - 450
  • [4] Bruyneel A. -V., 2020, KINESITHERAPIE REV, V21, P2
  • [5] Best Quantitative Tools for Assessing Static and Dynamic Standing Balance after Stroke: A Systematic Review
    Bruyneel, Anne-Violette
    Dube, Francois
    [J]. PHYSIOTHERAPY CANADA, 2021, 73 (04) : 329 - 340
  • [6] Postural organization and inter-limb coordination are altered after stroke when an isometric maximum bilateral pushing effort of the upper limbs is performed
    Bruyneel, Anne-Violette
    Higgins, Johanne
    Akremi, Haifa
    Aissaoui, Rachid
    Nadeau, Sylvie
    [J]. CLINICAL BIOMECHANICS, 2021, 86
  • [7] Learning effect on the dynamical strategies in sitting position on seesaw motion for idiopathic scoliosis patients
    Bruyneel, Anne-Violette
    Mesure, Serge
    [J]. NEUROSCIENCE LETTERS, 2013, 534 : 264 - 268
  • [8] Recovery of standing balance in postacute stroke patients: A rehabilitation cohort study
    de Haart, M
    Geurts, AC
    Huidekoper, SC
    Fasotti, L
    van Limbeek, J
    [J]. ARCHIVES OF PHYSICAL MEDICINE AND REHABILITATION, 2004, 85 (06): : 886 - 895
  • [9] Trunk control test as a functional predictor in stroke patients
    Duarte, E
    Marco, E
    Muniesa, JM
    Belmonte, R
    Diaz, P
    Tejero, M
    Escalada, F
    [J]. JOURNAL OF REHABILITATION MEDICINE, 2002, 34 (06) : 267 - 272
  • [10] Between-day reliability of centre of pressure measures for balance assessment in hemiplegic stroke patients
    Gasq, David
    Labrunee, Marc
    Amarantini, David
    Dupui, Philippe
    Montoya, Richard
    Marque, Philippe
    [J]. JOURNAL OF NEUROENGINEERING AND REHABILITATION, 2014, 11