Determining the change in length of the anterolateral ligament during knee motion: A three-dimensional optoelectronic analysis

被引:8
|
作者
Neri, Thomas [1 ,2 ,3 ]
Testa, Rodolphe [1 ]
Laurendon, Loic [2 ]
Dehon, Margaux [2 ]
Putnis, Sven [3 ]
Grasso, Samuel [3 ]
Parker, David A. [3 ]
Farizon, Frederic [1 ,2 ]
Philippot, Remi [1 ,2 ]
机构
[1] Univ Lyon, UJM St Etienne, Interuniv Lab Human Movement Sci, EA 7424, F-42023 St Etienne, France
[2] Univ Hosp St Etienne, Dept Orthoped Surg, St Priest En Jarez, France
[3] Sydney Orthopaed Res Inst, Sydney, NSW, Australia
关键词
Knee; Anterolateral ligament; Kinematic; Length; Optoelectronic system; ANTERIOR CRUCIATE LIGAMENT; JOINT COORDINATE SYSTEM; RECONSTRUCTION TECHNIQUE; KINEMATICS; ROTATION; ANATOMY;
D O I
10.1016/j.clinbiomech.2019.01.006
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Background: The variation of the anterolateral ligament (ALL) length during knee motion is still unclear, and the knee position in which a reconstruction graft should be tensioned remains controversial. The objective of this study was to determine the variation of the ALL length during knee motion using a three-dimensional optoelectronic system. Methods: Kinematic analyses of 20 cadaveric knees were performed using a Motion Analysis system. The variability of the measurements made during the five acquisition cycles was studied. Reliability was evaluated by two separate measurement sessions, with complete system reinstallation, using different cadavers and a new operator. The ALL length was analysed from extension to full flexion in three rotational conditions. Findings: When analysing the reliability of the five cycles, 82% of the measurements we found to have an Intra Class Correlation (ICC) > 0.85. The reproducibility of inter-sessional measures by different operators and different cadavers was either good (ICC > 0.75) or excellent (ICC > 0.85). The ALL length was maximum in full internal rotation with the knee at 25 of flexion. Interpretation: This three-dimensional optoelectronic protocol allowed us to analyse the variation of the ALL length during intact knee motion with good reliability and the required accuracy to analyse this variable. The maximal length and highest tension of the ALL was reported at 25 of knee flexion in internal rotation, suggesting this as the optimal position for the knee joint when tensioning an ALL reconstruction.
引用
收藏
页码:86 / 92
页数:7
相关论文
共 50 条
  • [31] Three-dimensional Motion Analysis of the Bending Exercise of the Knee Basis for the Development of a Support for the Older Adults
    Mitsuno, Tamaki
    Miyazawa, Natsuko
    TEXTILE BIOENGINEERING AND INFORMATICS SYMPOSIUM PROCEEDINGS, 2015, 2015, : 49 - 56
  • [32] Length change pattern of the ankle deltoid ligament during physiological ankle motion
    Cao, Shengxuan
    Wang, Chen
    Zhang, Chao
    Huang, Jiazhang
    Wang, Xu
    Ma, Xin
    FOOT AND ANKLE SURGERY, 2022, 28 (07) : 950 - 955
  • [33] Three-dimensional scapular kinematics during the throwing motion
    Meyer, Kristin E.
    Saether, Erin E.
    Soiney, Emily K.
    Shebeck, Meegan S.
    Paddock, Keith L.
    Ludewig, Paula M.
    JOURNAL OF APPLIED BIOMECHANICS, 2008, 24 (01) : 24 - 34
  • [34] Three-dimensional scapular kinematics during the throwing motion
    Meyer, Kristin E.
    Saether, Erin E.
    Soiney, Emily K.
    Shebeck, Meegan S.
    Paddock, Keith L.
    Ludewig, Paula M.
    Journal of Applied Biomechanics, 2008, 24 (01): : 24 - 34
  • [35] Three-dimensional motion of the pelvis during human walking
    Zhao, Lingyan
    Zhang, Lixun
    Wang, Lan
    Wang, Jian
    2005 IEEE International Conference on Mechatronics and Automations, Vols 1-4, Conference Proceedings, 2005, : 335 - 339
  • [36] Three-dimensional dynamic simulation of total knee replacement motion during a step-up task
    Piazza, SJ
    Delp, SL
    JOURNAL OF BIOMECHANICAL ENGINEERING-TRANSACTIONS OF THE ASME, 2001, 123 (06): : 599 - 606
  • [37] Three-Dimensional Patellar Motion at the Natural Knee during Passive Flexion/Extension. An In Vitro Study
    Belvedere, Claudio
    Leardini, Alberto
    Ensini, Andrea
    Bianchi, Luca
    Catani, Fabio
    Giannini, Sandro
    JOURNAL OF ORTHOPAEDIC RESEARCH, 2009, 27 (11) : 1426 - 1431
  • [38] VALIDATION OF A TWO-DIMENSIONAL MOTION ANALYSIS TECHNIQUE FOR QUANTIFYING DYNAMIC KNEE VALGUS DURING A DROP LANDING BY COMPARISONS TO DATA FROM THREE-DIMENSIONAL ANALYSIS
    Kagaya, Yoshinori
    Kawasaki, Wataru
    Fujii, Yasunari
    Nishizono, Hidetsugu
    JAPANESE JOURNAL OF PHYSICAL FITNESS AND SPORTS MEDICINE, 2010, 59 (04) : 407 - 414
  • [39] Three-dimensional dynamic analysis of knee joint during gait in medial knee osteoarthritis using loading axis of knee
    Nishino, Katsutoshi
    Omori, Go
    Koga, Yoshio
    Kobayashi, Koichi
    Sakamoto, Makoto
    Tanabe, Yuji
    Tanaka, Masaei
    Arakawa, Masaaki
    GAIT & POSTURE, 2015, 42 (02) : 127 - 132
  • [40] THREE-DIMENSIONAL KNEE BIOMECHANICS DURING GAIT PREDICT KNEE OSTEOARTHRITIS PROGRESSION
    Hatfield, G.
    Stanish, W. D.
    Hubley-Kozey, C. L.
    OSTEOARTHRITIS AND CARTILAGE, 2013, 21 : S22 - S23