Determining the change in length of the anterolateral ligament during knee motion: A three-dimensional optoelectronic analysis

被引:8
|
作者
Neri, Thomas [1 ,2 ,3 ]
Testa, Rodolphe [1 ]
Laurendon, Loic [2 ]
Dehon, Margaux [2 ]
Putnis, Sven [3 ]
Grasso, Samuel [3 ]
Parker, David A. [3 ]
Farizon, Frederic [1 ,2 ]
Philippot, Remi [1 ,2 ]
机构
[1] Univ Lyon, UJM St Etienne, Interuniv Lab Human Movement Sci, EA 7424, F-42023 St Etienne, France
[2] Univ Hosp St Etienne, Dept Orthoped Surg, St Priest En Jarez, France
[3] Sydney Orthopaed Res Inst, Sydney, NSW, Australia
关键词
Knee; Anterolateral ligament; Kinematic; Length; Optoelectronic system; ANTERIOR CRUCIATE LIGAMENT; JOINT COORDINATE SYSTEM; RECONSTRUCTION TECHNIQUE; KINEMATICS; ROTATION; ANATOMY;
D O I
10.1016/j.clinbiomech.2019.01.006
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Background: The variation of the anterolateral ligament (ALL) length during knee motion is still unclear, and the knee position in which a reconstruction graft should be tensioned remains controversial. The objective of this study was to determine the variation of the ALL length during knee motion using a three-dimensional optoelectronic system. Methods: Kinematic analyses of 20 cadaveric knees were performed using a Motion Analysis system. The variability of the measurements made during the five acquisition cycles was studied. Reliability was evaluated by two separate measurement sessions, with complete system reinstallation, using different cadavers and a new operator. The ALL length was analysed from extension to full flexion in three rotational conditions. Findings: When analysing the reliability of the five cycles, 82% of the measurements we found to have an Intra Class Correlation (ICC) > 0.85. The reproducibility of inter-sessional measures by different operators and different cadavers was either good (ICC > 0.75) or excellent (ICC > 0.85). The ALL length was maximum in full internal rotation with the knee at 25 of flexion. Interpretation: This three-dimensional optoelectronic protocol allowed us to analyse the variation of the ALL length during intact knee motion with good reliability and the required accuracy to analyse this variable. The maximal length and highest tension of the ALL was reported at 25 of knee flexion in internal rotation, suggesting this as the optimal position for the knee joint when tensioning an ALL reconstruction.
引用
收藏
页码:86 / 92
页数:7
相关论文
共 50 条
  • [21] Relationship between three-dimensional kinematics of knee and trunk motion during shuttle run cutting
    Nagano, Yasuharu
    Ida, Hirofumi
    Akai, Masami
    Fukubayashi, Toru
    JOURNAL OF SPORTS SCIENCES, 2011, 29 (14) : 1525 - 1534
  • [22] Activation of Pelvic Floor Muscle During Ankle Posture Change on the Basic of a Three-Dimensional Motion Analysis System
    Lee, Kyeongjin
    MEDICAL SCIENCE MONITOR, 2018, 24 : 7223 - 7230
  • [23] Effect of Mediolateral Knee Displacement on Ligaments and Muscles around Knee Joint: Quantitative Analysis with Three-Dimensional Musculoskeletal Ligament Knee Model
    Ishikawa, Yuki
    An, Qi
    Tamura, Yusuke
    Yamashita, Atsushi
    Oka, Hiroyuki
    Asama, Hajime
    INTELLIGENT AUTONOMOUS SYSTEMS 12 , VOL 2, 2013, 194 : 447 - +
  • [24] Three-Dimensional Motion Analysis of Mochi Pounding
    Goto, Akihiko
    Sugiyama, Naoki
    Goto, Daigo
    Ota, Tomoko
    Hamada, Hiroyuki
    ADVANCES IN MANUFACTURING, PRODUCTION MANAGEMENT AND PROCESS CONTROL, 2020, 971 : 233 - 243
  • [25] Three-dimensional analysis of cricoarytenoid joint motion
    Wang, RC
    LARYNGOSCOPE, 1998, 108 (04): : 1 - 17
  • [26] A three-dimensional musculoskeletal model of the human knee joint. Part 2: Analysis of ligament function
    Pandy, Marcus G.
    Sasaki, Kotaro
    Computer Methods in Biomechanics and Biomedical Engineering, 1998, 1 (04): : 265 - 283
  • [27] Three-Dimensional Vision and Human Motion Analysis
    Sawasaki, Naoyuki
    ADVANCED ROBOTICS, 2009, 23 (11) : 1517 - 1521
  • [28] The effect of healing in the medial collateral ligament of human knee joint: A three-dimensional finite element analysis
    Wan, Chao
    Hao, Zhixiu
    Wen, Shizhu
    PROCEEDINGS OF THE INSTITUTION OF MECHANICAL ENGINEERS PART H-JOURNAL OF ENGINEERING IN MEDICINE, 2016, 230 (09) : 867 - 875
  • [29] Three-dimensional knee kinematics and stability in patients with a posterior cruciate ligament tear
    Jonsson, H
    Kärrholm, J
    JOURNAL OF ORTHOPAEDIC RESEARCH, 1999, 17 (02) : 185 - 191
  • [30] Analysis of knee-bending motion through three-dimensional scanning for advanced brace design
    Pierre, Ringenbach
    Yu, Annie
    Zhang, Yijia
    TEXTILE RESEARCH JOURNAL, 2024, : 2682 - 2694