Analytical and Multiphysics Approach to the Optimal Design of a 10-MW DFIG for Direct-Drive Wind Turbines

被引:55
作者
Colli, Vincenzo Delli [1 ]
Marignetti, Fabrizio [1 ]
Attaianese, Ciro [1 ]
机构
[1] Univ Cassino, Maurizio Scarano Dept, I-03043 Cassino, Italy
关键词
AC generators; induction machines; wind power; MAGNET SYNCHRONOUS GENERATOR; OPTIMIZATION;
D O I
10.1109/TIE.2011.2168790
中图分类号
TP [自动化技术、计算机技术];
学科分类号
0812 ;
摘要
This work deals with a 10-MW doubly fed induction generator (DFIG) for direct-drive operation of wind turbines with a reduced-size converter. The work includes a lumped parameter design, an optimization procedure, a finite-element analysis (FEA), and an electrical performance assessment. A monetary cost was assumed as a cost function, and an approximation of the construction cost as a function of the axial length was obtained. The found solutions were checked by FEA in order to assure the mechanical feasibility. Further verifications were developed to allow a conclusive performance evaluation. The optimization improved the cost of the proposed DFIG, including materials, losses, and converter, making it slightly cheaper than an available permanent-magnet synchronous generator.
引用
收藏
页码:2791 / 2799
页数:9
相关论文
共 30 条
[1]  
American Superconductor, SEATITAN DAT
[2]  
[Anonymous], UE EP6 UPWIND PROJEC
[3]   Design and optimization of a nine-phase axial-flux PM synchronous generator with concentrated winding for direct-drive wind turbine [J].
Brisset, Stephane ;
Vizireanu, Darius ;
Brochet, Pascal .
IEEE TRANSACTIONS ON INDUSTRY APPLICATIONS, 2008, 44 (03) :707-715
[4]   An axial-flux permanent-magnet synchronous generator for a direct-coupled wind-turbine system [J].
Chan, T. F. ;
Lai, L. L. .
IEEE TRANSACTIONS ON ENERGY CONVERSION, 2007, 22 (01) :86-94
[5]   A Review of the State of the Art of Power Electronics for Wind Turbines [J].
Chen, Zhe ;
Guerrero, Josep M. ;
Blaabjerg, Frede .
IEEE TRANSACTIONS ON POWER ELECTRONICS, 2009, 24 (08) :1859-1875
[6]   2-D Mechanical and Magnetic Analysis of a 10 MW Doubly Fed Induction Generator for Direct-Drive Wind Turbines [J].
Colli, V. Delli ;
Marignetti, F. ;
Attaianese, C. .
IECON: 2009 35TH ANNUAL CONFERENCE OF IEEE INDUSTRIAL ELECTRONICS, VOLS 1-6, 2009, :3668-+
[7]  
de Vries E., 2009, RENEW ENERGY WOR JUL, P97
[8]  
Delli Colli V., 2009, P IEEE PES IAS 28 30, P1, DOI DOI 10.1109/SAE.2009.5534868
[9]   Sensorless Control for a Switched Reluctance Wind Generator, Based on Current Slopes and Neural Networks [J].
Echenique, Estanislao ;
Dixon, Juan ;
Cardenas, Roberto ;
Pena, Ruben .
IEEE TRANSACTIONS ON INDUSTRIAL ELECTRONICS, 2009, 56 (03) :817-825
[10]   Optimal Operation of Offshore Wind Farms With Line-Commutated HVDC Link Connection [J].
Eduardo Montilla-DJesus, Miguel ;
Santos-Martin, David ;
Arnaltes, Santiago ;
Castronuovo, Edgardo D. .
IEEE TRANSACTIONS ON ENERGY CONVERSION, 2010, 25 (02) :504-513