Bacterial contamination of platelet components: potential solutions to prevent transfusion-related sepsis

被引:1
作者
Corash, Laurence [1 ,2 ]
机构
[1] Cerus Corp, Med Affairs, Concord, CA USA
[2] Univ Calif San Francisco, Dept Lab Med, San Francisco, CA 94143 USA
关键词
bacteria; pathogen inactivation; pathogen reduction; platelet components; transfusion-related sepsis; PATHOGEN INACTIVATION TREATMENT; 6 YEARS EXPERIENCE; PROPIONIBACTERIUM-ACNES; APHERESIS PLATELETS; PHOTOCHEMICAL INACTIVATION; SALMONELLA SEPTICEMIA; DETECTION SYSTEM; CLINICAL SAFETY; AMOTOSALEN HCL; RESIDUAL RISK;
D O I
10.1586/EHM.11.53
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Bacterial contamination of platelet components (PC) is the most prevalent risk for transfusion-transmitted infection. Based on the recent studies with optimal culture methods of expired PC, the prevalence of bacterial contamination is estimated to occur in approximately one in 750 to one in 1000 PC. Only within the last few years have the magnitude of the risks and the range of clinical outcomes associated with bacterial contamination been extensively characterized. Despite increased recognition of bacterial contamination of PC, transfusion-related sepsis is infrequently reported. This has largely been attributed to passive reporting systems, and low levels of clinical awareness for transfusion-related sepsis by primary care physicians. The risk for transfusion of contaminated PC has generally been characterized per component. Importantly, because patients require repeated transfusions of PC during a period of transfusion-dependent thrombocytopenia, it is appropriate to express the risk to receive a contaminated PC on a patient exposure basis. Assuming that the average hematology oncology patient may receive seven PC during a 28-day period of support, the risk of exposure to a contaminated PC is in the range of one in 150 per patient. This level of risk would not be acceptable for other intravenous medications. With increased appreciation of the risk of bacterial contamination, methods were developed to limit the risk of transfusion-transmitted bacteremia. This article focuses on those interventions that have been implemented in routine practice. The most important methods employed to mitigate the risk are improved skin disinfection, initial blood draw diversion, bacterial detection and pathogen inactivation/reduction. These technologies are now undergoing increased use in the clinical practice of transfusion medicine. With increased use, additional data are being generated to more fully characterize the effects of these interventions. Improved disinfection, blood diversion and bacterial detection have decreased, but not resolved the risk of bacterial contamination. Pathogen inactivation/reduction offers the potential for a further substantial decrease of the risk for transfusion of PC contaminated with bacteria.
引用
收藏
页码:509 / 525
页数:17
相关论文
共 93 条
[1]   Hemovigilance network in France:: organization and analysis of immediate transfusion incident reports from 1994 to 1998 [J].
Andreu, G ;
Morel, P ;
Forestier, F ;
Debeir, J ;
Rebibo, D ;
Janvier, G ;
Hervé, P .
TRANSFUSION, 2002, 42 (10) :1356-1364
[2]  
Barbara J, 2001, SEMIN HEMATOL, V38, P1
[3]   The residual risk of sepsis: modeling the effect of concentration on bacterial detection in two-bottle culture systems and an estimation of false-negative culture rates [J].
Benjamin, Richard J. ;
Wagner, Stephen J. .
TRANSFUSION, 2007, 47 (08) :1381-1389
[4]   Skin disinfection with a single-step 2% chlorhexidine swab is more effective than a two-step povidone-iodine method in preventing bacterial contamination of apheresis platelets [J].
Benjamin, Richard J. ;
Dy, Beth ;
Warren, Ryan ;
Lischka, Michael ;
Eder, Anne F. .
TRANSFUSION, 2011, 51 (03) :531-538
[5]   Bacterial detection of platelets: Current problems and possible resolutions [J].
Blajchman, MA ;
Beckers, EAM ;
Dickmeiss, E ;
Lin, L ;
Moore, G ;
Muylle, L .
TRANSFUSION MEDICINE REVIEWS, 2005, 19 (04) :259-272
[6]   Improving the bacteriological safety of platelet transfusions [J].
Blajchman, MA ;
Goldman, M ;
Baeza, F .
TRANSFUSION MEDICINE REVIEWS, 2004, 18 (01) :11-24
[7]   PLATELET TRANSFUSION-INDUCED SERRATIA-MARCESCENS SEPSIS DUE TO VACUUM TUBE CONTAMINATION [J].
BLAJCHMAN, MA ;
THORNLEY, JH ;
RICHARDSON, H ;
ELDER, D ;
SPIAK, C ;
RACHER, J .
TRANSFUSION, 1979, 19 (01) :39-44
[8]   Bacterial contamination of platelet concentrates: Incidence, significance, and prevention [J].
Blajchman, MA ;
Goldman, M .
SEMINARS IN HEMATOLOGY, 2001, 38 (04) :20-26
[9]   BACTERIAL SEPSIS SECONDARY TO PLATELET TRANSFUSION - AN ADVERSE EFFECT OF EXTENDED STORAGE AT ROOM-TEMPERATURE [J].
BRAINE, HG ;
KICKLER, TS ;
CHARACHE, P ;
NESS, PM ;
DAVIS, J ;
REICHART, C ;
FULLER, AK .
TRANSFUSION, 1986, 26 (04) :391-393
[10]   Investigation of an isolate of Staphylococcus lugdunensis implicated in a platelet fatality:: a possible advantage of the use of an anaerobic bottle [J].
Brecher, Mark E. ;
Hay, Shauna N. .
TRANSFUSION, 2007, 47 (08) :1390-1394