Insertion and fixation of fiducial markers for setup and tracking of lung tumors in radiotherapy

被引:134
作者
Imura, M
Yamazaki, K
Shirato, H
Onimaru, R
Fujino, M
Shimizu, S
Harada, T
Ogura, S
Dosaka-Akita, H
Miyasaka, K
Nishimura, M
机构
[1] Hokkaido Univ, Sch Med, Dept Med 1, Kita Ku, Sapporo, Hokkaido 0608638, Japan
[2] Hokkaido Univ, Sch Med, Dept Radiol, Sapporo, Hokkaido 0608638, Japan
[3] Iwamizawa Municipal Hosp, Dept Med, Iwamizawa, Japan
[4] Sapporo City Gen Hosp, Dept Resp Dis, Sapporo, Hokkaido, Japan
[5] Hokkaido Univ, Grad Sch Med, Dept Med Oncol, Sapporo, Hokkaido 0608638, Japan
来源
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS | 2005年 / 63卷 / 05期
关键词
real-time tumor-tracking radiotherapy; four-dimensional radiotherapy; fiducial marker; bronchoscopy;
D O I
10.1016/j.ijrobp.2005.04.024
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Purpose: Internal 1.5-mm fiducial markers were used in real-time tumor-tracking radiotherapy (RT) for lung cancer. The fixation rate of the markers using the bronchial insertion technique, reliability of the setup using markers around the target volume, dislocation of the markers after real-time tumor-tracking RT, and long-term toxicity of marker insertion were investigated. Methods and Materials: Between July 2000 and April 2004, 154 gold markers were inserted into 57 patients with peripheral lung cancer. The distances between the implanted markers in 198 measurements in 71 setups in 11 patients were measured using two sets of orthogonal diagnostic X-ray images of the real-time tumor-tracking RT system. The distance between the markers and the chest wall was also measured in a transaxial CT image on 186 occasions in 48 patients during treatment planning and during follow-up. The median treatment time was 6 days (range, 4-14 days). Results: In 115 (75%) of the 154 inserted markers, the gold marker was detected throughout the treatment period. In 122 markers detected at CT planning, 115 (94%) were detected until the end of treatment. The variation in the distances between the implanted markers was within +/- 2 mm in 95% and 1 mm in 80% during treatment. The variation in the distances between the implanted markers was > 2 mm in at least one direction in 9% of the setups for which reexamination with a CT scan was indicated. The fixation rate in the left upper lobe was lower than in the other lobes. A statistically significant relationship was found between a shorter distance between the markers and the chest wall and the fixation rate, suggesting that the markers in the smaller bronchial lumens fixed better than those in the larger lumens. A learning curve among the endoscopists was suggested in the fixation rate. The distance between the markers and the chest wall changed significantly within a median of 44 days (range, 16-181 days) after treatment. Conclusion: The fixation of markers into the bronchial tree was useful for the setup for peripheral lung cancer and had an accuracy of 2 mm during the 1-2-week treatment period. The relationship between the markers and tumor can change significantly after 2 weeks, suggesting that adaptive four-dimensional RT is required. (c) 2005 Elsevier Inc.
引用
收藏
页码:1442 / 1447
页数:6
相关论文
共 19 条
  • [1] Integrated radiotherapy imaging system (IRIS): design considerations of tumour tracking with linac gantry-mounted diagnostic x-ray systems with flat-panel detectors
    Berbeco, RI
    Jiang, SB
    Sharp, GC
    Chen, GTY
    Mostafavi, H
    Shirato, H
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2004, 49 (02) : 243 - 255
  • [2] Ebe K, 2004, INT J RADIAT ONCOL, V60, pS604
  • [3] Small-volume image-guided radiotherapy using hypofractionated, coplanar, and noncoplanar multiple fields for patients with inoperable stage I nonsmall cell lung carcinomas
    Fukumoto, S
    Shirato, H
    Shimzu, S
    Ogura, S
    Onimaru, R
    Kitamura, K
    Yamazaki, K
    Miyasaka, K
    Nishimura, M
    Dosaka-Akita, H
    [J]. CANCER, 2002, 95 (07) : 1546 - 1553
  • [4] Real-time tumor-tracking radiation therapy for lung carcinoma by the aid of insertion of a gold marker using bronchofiberscopy
    Harada, T
    Shirato, H
    Ogura, S
    Oizumi, S
    Yamazaki, K
    Shimizu, S
    Onimaru, R
    Miyasaka, K
    Nishimura, M
    Dosaka-Akita, H
    [J]. CANCER, 2002, 95 (08) : 1720 - 1727
  • [5] Acquiring 4D thoracic CT scans using a multislice helical method
    Keall, PJ
    Starkschall, G
    Shukla, H
    Forster, KM
    Ortiz, V
    Stevens, CW
    Vedam, SS
    George, R
    Guerrero, T
    Mohan, R
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2004, 49 (10) : 2053 - 2067
  • [6] Registration accuracy and possible migration of internal fiducial gold marker implanted in prostate and liver treated with real-time tumor-tracking radiation therapy (RTRT)
    Kitamura, K
    Shirato, H
    Shimizu, S
    Shinohara, N
    Harabayashi, T
    Shimizu, T
    Kodama, Y
    Endo, H
    Onimaru, R
    Nishioka, S
    Aoyama, H
    Tsuchiya, K
    Miyasaka, K
    [J]. RADIOTHERAPY AND ONCOLOGY, 2002, 62 (03) : 275 - 281
  • [7] Measurement of lung tumor motion using respiration-correlated CT
    Mageras, GS
    Pevsner, A
    Yorke, ED
    Rosenzweig, KE
    Ford, EC
    Hertanto, A
    Larson, SM
    Lovelock, DM
    Erdi, YE
    Nehmeh, SA
    Humm, JL
    Ling, CC
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2004, 60 (03): : 933 - 941
  • [8] Tolerance of organs at risk in small-volume, hypofractionated, image-guided radiotherapy for primary and metastatic lung cancers
    Onimaru, R
    Shirato, H
    Shimizu, S
    Kitamura, K
    Xu, B
    Fukumoto, S
    Chang, TC
    Fujita, K
    Oita, M
    Miyasaka, K
    Nishimura, M
    Dosaka-Akita, H
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2003, 56 (01): : 126 - 135
  • [9] Calculation of rotational setup error using the real-time tracking radiation therapy (RTRT) system and its application to the treatment of spinal schwannoma
    Onimaru, R
    Shirato, H
    Aoyama, H
    Kitakura, K
    Seki, T
    Hida, K
    Fujita, K
    Kagei, K
    Nishioka, T
    Kunieda, T
    Iwasaki, Y
    Miyasaka, K
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2002, 54 (03): : 939 - 947
  • [10] Precise and real-time measurement of 3D tumor motion in lung due to breathing and heartbeat, measured during radiotherapy
    Seppenwoolde, Y
    Shirato, H
    Kitamura, K
    Shimizu, S
    van Herk, M
    Lebesque, JV
    Miyasaka, K
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2002, 53 (04): : 822 - 834