Automatic PET-CT Image Registration Method Based on Mutual Information and Genetic Algorithms

被引:24
作者
Marinelli, Martina [1 ]
Positano, Vincenzo [2 ]
Tucci, Francesco [3 ]
Neglia, Danilo [2 ]
Landini, Luigi [2 ]
机构
[1] CNR, Inst Clin Physiol, I-56124 Pisa, Italy
[2] CNR Reg Toscana, Fdn Gabriele Monasterio, I-56124 Pisa, Italy
[3] Univ Pisa, Dept Informat Engn, I-56126 Pisa, Italy
关键词
INTERPOLATION ARTIFACTS; SPECT; MAXIMIZATION; ALIGNMENT; STRESS;
D O I
10.1100/2012/567067
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
Hybrid PET/CT scanners can simultaneously visualize coronary artery disease as revealed by computed tomography (CT) and myocardial perfusion as measured by positron emission tomography (PET). Manual registration is usually required in clinical practice to compensate spatial mismatch between datasets. In this paper, we present a registration algorithm that is able to automatically align PET/CT cardiac images. The algorithm bases on mutual information (MI) as registration metric and on genetic algorithm as optimization method. A multiresolution approach was used to optimize the processing time. The algorithm was tested on computerized models of volumetric PET/CT cardiac data and on real PET/CT datasets. The proposed automatic registration algorithm smoothes the pattern of the MI and allows it to reach the global maximum of the similarity function. The implemented method also allows the definition of the correct spatial transformation that matches both synthetic and real PET and CT volumetric datasets.
引用
收藏
页数:12
相关论文
共 28 条
[1]  
[Anonymous], 2000, Evolutionary computation
[2]  
Bindaut L. M., 1993, J MAGN RESON, V13, P648
[3]   Mutual information-based CT-MR brain image registration using generalized partial volume joint histogram estimation [J].
Chen, HM ;
Varshney, PK .
IEEE TRANSACTIONS ON MEDICAL IMAGING, 2003, 22 (09) :1111-1119
[4]  
Clarysse P., 2001, LECT NOTES COMPUTER, P557
[5]  
Collignon A., 1995, COMPUTER VISION VIRT, P193
[6]   Non-rigid image registration: theory and practice [J].
Crum, WR ;
Hartkens, T ;
Hill, DLG .
BRITISH JOURNAL OF RADIOLOGY, 2004, 77 :S140-S153
[7]   Automatic registration and alignment on a template of cardiac stress and rest reoriented SPECT images [J].
Declerck, J ;
Feldmar, J ;
Goris, ML ;
Betting, F .
IEEE TRANSACTIONS ON MEDICAL IMAGING, 1997, 16 (06) :727-737
[8]  
Dey D, 1999, J NUCL MED, V40, P448
[9]   New technology for noninvasive evaluation of coronary artery disease [J].
Di Carli, Marcelo F. ;
Hachamovitch, Rory .
CIRCULATION, 2007, 115 (11) :1464-1480
[10]  
Eberl S, 1996, J NUCL MED, V37, P137