Improved Active Power Filter Performance Based on an Indirect Current Control Technique

被引:25
作者
Adel, Mohamed [1 ]
Zaid, Sherif [2 ]
Mahgoub, Osama [2 ]
机构
[1] Banha Univ, Fac Engn, Dept Elect Engn & Technol, Qalyobia, Egypt
[2] Cairo Univ, Fac Engn, Dept Elect Power, Giza 12211, Egypt
关键词
Active power filter; Direct current control; Indirect current control; Total harmonic distortion; REACTIVE POWER;
D O I
10.6113/JPE.2011.11.6.931
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
This paper presents a method for the performance improvement of a shunt active power filter (SAPF) using the indirect current control (ICC) scheme. Compared to the conventional direct current control (DCC) scheme, the ICC gives better performance with a lower number of sensors. A simplified and efficient control algorithm using a low cost Intel 80C196KC microcontroller is implemented using only two current sensors for the source current and one voltage sensor for the DC-link voltage of the SAPF circuit. The objective is to eliminate harmonics and to compensate the reactive power produced by non-linear loads such as an uncontrolled rectifier feeding an inductive load. The APF is realized using a three phase voltage source inverter (VSI) with a dc bus capacitor. Experimental results are presented to prove the better performance of the ICC method over the DCC one.
引用
收藏
页码:931 / 937
页数:7
相关论文
共 14 条
[1]   New trends in active filters for power conditioning [J].
Akagi, H .
IEEE TRANSACTIONS ON INDUSTRY APPLICATIONS, 1996, 32 (06) :1312-1322
[2]   An improved control algorithm of shunt active filter for voltage regulation, harmonic elimination, power-factor correction, and balancing of nonlinear loads [J].
Chandra, A ;
Singh, B ;
Singh, BN ;
Al-Haddad, K .
IEEE TRANSACTIONS ON POWER ELECTRONICS, 2000, 15 (03) :495-507
[3]   Review of the control strategies applied to active power filters [J].
Chen, DH ;
Xie, SJ .
PROCEEDINGS OF THE 2004 IEEE INTERNATIONAL CONFERENCE ON ELECTRIC UTILITY DEREGULATION, RESTRUCTURING AND POWER TECHNOLOGIES, VOLS 1 AND 2, 2004, :666-670
[4]   A Novel Three-phase Active Power Filter Based on Instantaneous Reactive Power Theory [J].
Dai, Wenjin ;
Wang, Yu .
2008 WORKSHOP ON POWER ELECTRONICS AND INTELLIGENT TRANSPORTATION SYSTEM, PROCEEDINGS, 2008, :375-379
[5]   A hybrid active filter for damping of harmonic resonance in industrial power systems [J].
Fujita, H ;
Yamasaki, T ;
Akagi, H .
IEEE TRANSACTIONS ON POWER ELECTRONICS, 2000, 15 (02) :215-222
[6]   Indirect current control techniques of three phase APF using fuzzy logic and proportional integral controller:: Comparative analysis [J].
Hamadi, A ;
Al-Haddad, K ;
Lagacé, PJ ;
Chandra, A .
2004 11TH INTERNATIONAL CONFERENCE ON HARMONICS AND QUALITY OF POWER, 2004, :362-367
[7]   Design simulation and experimental investigations on a shunt active power filter for harmonics and reactive power compensation [J].
Jain, SK ;
Agarwal, P ;
Gupta, HO .
ELECTRIC POWER COMPONENTS AND SYSTEMS, 2003, 31 (07) :671-692
[8]  
Louie K.W., 2006, Transmission Distribution Conference and Exposition: Latin America, P1, DOI [DOI 10.1109/TDCLA.2006.311607, 10.1109/TDCLA.2006.311607]
[9]  
Mohan N., 1989, POWER ELECT CONVERTE, P425
[10]   A 3-PHASE ACTIVE POWER FILTER OPERATING WITH FIXED SWITCHING FREQUENCY FOR REACTIVE POWER AND CURRENT HARMONIC COMPENSATION [J].
MORAN, LA ;
DIXON, JW ;
WALLACE, RR .