Interpolation methods for time-delay estimation using cross-correlation method for blood velocity measurement

被引:108
作者
Lai, XM
Torp, H
机构
[1] Univ Toronto, Sunnybrook Hlth Sci Ctr, Dept Med Biophys, Toronto, ON M4N 3M5, Canada
[2] Norwegian Univ Sci & Technol, Dept Physiol & Biomed Engn, N-7005 Trondheim, Norway
关键词
D O I
10.1109/58.753016
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
The cross-correlation method (CCM) for blood flow velocity measurement using Doppler ultrasound is based on time delay estimation of echoes from pulse-to-pulse. The sampling frequency of the received signal is usually kept as low as possible in order to reduce computational complexity, and the peak in the correlation function is found by interpolating the correlation function. The parabolic-fit interpolation method introduces a bias at low sampling rate to the ultrasound center frequency ratio. In this study, four different methods are suggested to improve the estimation accuracy: (1) Parabolic interpolation with bias-compensation, derived from a theoretical signal model. (2) Parabolic interpolation combined with linear filter interpolation of the correlation function. (3) Parabolic interpolation to the complex correlation function envelope. (4) Matched filter interpolation applied to the correlation function. The new interpolation methods are analysed both by computer simulated signals and RF-signals recorded from a patient with time delay larger than 1/f(0), where f(0) is the center frequency. The simulation results show that these methods are more accurate than the parabolic-fit method. From the simulation, the worst estimation accuracy is about 1.25% of 1/f(0) for the parabolic-fit interpolation, and it is improved by the above methods to less than 0.5% of 1/f(0) when the sampling rate is 10 MHz, the center frequency is 2.5 MHz and the bandwidth is 1 MHz. This improvement also can be observed in the experimental data. Furthermore, the matched filter interpolation gives the best performance when signal-to-noise ratio (SNR) is low. This is verified both by simulation and experimentation.
引用
收藏
页码:277 / 290
页数:14
相关论文
共 20 条
[1]   TIME DOMAIN FORMULATION OF PULSE-DOPPLER ULTRASOUND AND BLOOD VELOCITY ESTIMATION BY CROSS-CORRELATION [J].
BONNEFOUS, O ;
PESQUE, P .
ULTRASONIC IMAGING, 1986, 8 (02) :73-85
[2]  
Bonnefous O., 1986, P IEEE ULTR S, P885
[3]   ANALYSIS OF DISCRETE IMPLEMENTATION OF GENERALIZED CROSS CORRELATOR [J].
BOUCHER, RE ;
HASSAB, JC .
IEEE TRANSACTIONS ON ACOUSTICS SPEECH AND SIGNAL PROCESSING, 1981, 29 (03) :609-611
[4]   METHODS FOR ESTIMATION OF SUBSAMPLE TIME DELAYS OF DIGITIZED ECHO SIGNALS [J].
CESPEDES, I ;
HUANG, Y ;
OPHIR, J ;
SPRATT, S .
ULTRASONIC IMAGING, 1995, 17 (02) :142-171
[5]   EXPERIMENTAL EVALUATION OF THE CORRELATION INTERPOLATION TECHNIQUE TO MEASURE REGIONAL TISSUE VELOCITY [J].
DEJONG, PGM ;
ARTS, T ;
HOEKS, APG ;
RENEMAN, RS .
ULTRASONIC IMAGING, 1991, 13 (02) :145-161
[6]   DETERMINATION OF TISSUE MOTION VELOCITY BY CORRELATION INTERPOLATION OF PULSED ULTRASONIC ECHO SIGNALS [J].
DEJONG, PGM ;
ARTS, T ;
HOEKS, APG ;
RENEMAN, RS .
ULTRASONIC IMAGING, 1990, 12 (02) :84-98
[7]  
DOUGHERTY ER, 1990, PROBABILITY STAT ENG, P309
[8]   A NEW WIDE-BAND SPREAD TARGET MAXIMUM-LIKELIHOOD ESTIMATOR FOR BLOOD VELOCITY ESTIMATION .1. THEORY [J].
FERRARA, KW ;
ALGAZI, VR .
IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 1991, 38 (01) :1-16
[9]   THE EFFECT OF FREQUENCY-DEPENDENT SCATTERING AND ATTENUATION ON THE ESTIMATION OF BLOOD VELOCITY USING ULTRASOUND [J].
FERRARA, KW ;
ALGAZI, VR ;
LIU, JX .
IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 1992, 39 (06) :754-767
[10]   FLOW VELOCITY PROFILE VIA TIME-DOMAIN CORRELATION ERROR ANALYSIS AND COMPUTER-SIMULATION [J].
FOSTER, SG ;
EMBREE, PM ;
OBRIEN, WD .
IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 1990, 37 (03) :164-175