Fluorescent hollow ZrO2@CdTe nanoparticles-based lateral flow assay for simultaneous detection of C-reactive protein and troponin T

被引:10
|
作者
Liu, Xin [1 ,2 ,3 ]
Ren, Xiangling [1 ,3 ,4 ]
Chen, Lufeng [5 ,6 ]
Zou, Jian [1 ,2 ,3 ]
Li, Ting [1 ,3 ,4 ]
Tan, Longfei [1 ,3 ]
Fu, Changhui [1 ,3 ]
Wu, Qiong [1 ,3 ]
Li, Chaohui [7 ]
Wang, Jiayi [7 ]
Huang, Zhongbing [2 ]
Meng, Xianwei [1 ,3 ]
机构
[1] Chinese Acad Sci, Tech Inst Phys & Chem, Lab Controllable Preparat & Applicat Nanomat, Beijing 100190, Peoples R China
[2] Sichuan Univ, Coll Mat Sci & Engn, Chengdu 610065, Peoples R China
[3] Chinese Acad Sci, Tech Inst Phys & Chem, CAS Key Lab Cryogen, Beijing 100190, Peoples R China
[4] Univ Chinese Acad Sci, Beijing 100049, Peoples R China
[5] Shanxi Med Univ, Clin Med Sch 1, Taiyuan 030001, Shanxi, Peoples R China
[6] Shanxi Med Univ, Hosp 1, Taiyuan 030001, Shanxi, Peoples R China
[7] Beijing Zhongsheng Jinyu Diagnost Technol Corp Co, Beijing 102200, Peoples R China
基金
北京市自然科学基金; 中国国家自然科学基金;
关键词
ZrO2@CdTe nanoparticles; Lateral flow assay; Fluorescence detection; Multiple detection; Cardiac biomarkers; QUANTITATIVE DETECTION; SENSITIVE DETECTION; QUANTUM DOTS; TEST STRIP; NANOPLATFORM; BIOSENSOR; POINT;
D O I
10.1007/s00604-021-04865-3
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Highly fluorescent hollow ZrO2@CdTe nanoparticles (NPs) were synthesized efficiently via the hydrothermal method. By changing the hydrothermal time of ZrO2@CdTe NP, the peaks of fluorescence spectra measured at fluorescent excitation of 330 nm were at 540 nm, 590 nm, and 640 nm, respectively. Hollow ZrO2 NPs have a uniformcore-shell structure with the size of 178 +/- 10 nm and shell of 19 +/- 4 nm. The as-prepared yellow-ZrO2@CdTe NPs were used to develop lateral flow assay (LFA) for the sensitive and qualitative detection of C-reactive protein (CRP). The visual limit of detection of the LFA for the CRP antigen was 1 mu g/L within 20 min, which is 1000-fold lower than that of colloidal gold-based LFA. In addition, a multiplex lateral flow assay (mLFA) was developed using the as-prepared green and red-ZrO2@CdTe NPs for the simultaneous, specific, sensitive, and qualitative detection of CRP and troponin T (cTnT). The visual limits of detection of CRP and cTnT in mLFA were 10 mu g/L and 0.1 mg/L, respectively. The excellent performance of ZrO2@CdTe NPs should facilitate their application in point-of-care technology for the detection of other biomarkers.
引用
收藏
页数:10
相关论文
共 27 条
  • [21] SERS-based lateral flow assay for quantitative detection of C-reactive protein as an early bio-indicator of a radiation-induced inflammatory response in nonhuman primates
    Rong, Zhen
    Xiao, Rui
    Xing, Shuang
    Xiong, Guolin
    Yu, Zuyin
    Wang, Limei
    Jia, Xiaofei
    Wang, Keli
    Cong, Yuwen
    Wang, Shengqi
    ANALYST, 2018, 143 (09) : 2115 - 2121
  • [22] InfectCheck CRP barcode-style lateral flow assay for semi-quantitative detection of C-reactive protein in distinguishing between bacterial and viral infections
    Leung, Wingman
    Chan, Cangel Puiyee
    Rainer, Timothy H.
    Ip, Margaret
    Cautherley, George W. H.
    Renneberg, Reinhard
    JOURNAL OF IMMUNOLOGICAL METHODS, 2008, 336 (01) : 30 - 36
  • [23] Development of a gold-nanorod-based lateral flow immunoassay for a fast and dual-modal detection of C-reactive protein in clinical plasma samples
    Pang, Renzhu
    Zhu, Qunyan
    Wei, Jia
    Wang, Yaoqi
    Xu, Fengqin
    Meng, Xianying
    Wang, Zhenxin
    RSC ADVANCES, 2021, 11 (45) : 28388 - 28394
  • [24] Development of spike protein-based fluorescence lateral flow assay for the simultaneous detection of SARS-CoV-2 specific IgM and IgG
    Wang, Chongwen
    Shi, Dawei
    Wan, Nan
    Yang, Xingsheng
    Liu, Haifeng
    Gao, Huixia
    Zhang, Minli
    Bai, Zikun
    Li, Dingchen
    Dai, Erhei
    Rong, Zhen
    Wang, Shengqi
    ANALYST, 2021, 146 (12) : 3908 - 3917
  • [25] Electrochemiluminescence-Incorporated Lateral Flow Immunosensors Using Ru(bpy)32+-Labeled Gold Nanoparticles for the Full-Range Detection of Physiological C-Reactive Protein Levels
    Hong, Donggu
    Kim, Kihyeun
    Jo, Eun-Jung
    Kim, Min-Gon
    ANALYTICAL CHEMISTRY, 2021, 93 (22) : 7925 - 7932
  • [26] A sensitive and quantitative prognosis of C-reactive protein at picogram level using mesoporous silica encapsulated core-shell up-conversion nanoparticle based lateral flow strip assay
    Guo, Jiuchuan
    Chen, Shuqin
    Tian, Shulin
    Liu, Ke
    Ma, Xing
    Guo, Jinhong
    TALANTA, 2021, 230
  • [27] Molybdenum Disulfide (MoS2)/Gold Nanoparticles (AuNPs)-based Field-effect Transistor for C-reactive Protein Detection: Early Diagnosis of Cardiovascular Disease
    Dalila, N. R.
    Arshad, M. K. Md
    Gopinath, Subash C. B.
    Nuzaihan, M. M. N.
    Ibau, C.
    Letchuman, Iswary
    2019 IEEE INTERNATIONAL CONFERENCE ON SENSORS AND NANOTECHNOLOGY (SN), 2019, : 137 - 140