Non-Invasive Screening Tool to Detect Anemia

被引:0
|
作者
Ajmal, A. A. [1 ]
Shankarnath, S. [1 ]
Athif, Mohamed [2 ]
Jayatunga, E. H. [1 ]
机构
[1] Univ Ruhuna, Dept Elect & Informat Engn, Matara, Sri Lanka
[2] Boston Univ, Dept Biomed Engn, Boston, MA 02215 USA
来源
2019 IEEE HEALTHCARE INNOVATIONS AND POINT OF CARE TECHNOLOGIES (HI-POCT) | 2019年
关键词
D O I
10.1109/hi-poct45284.2019.8962856
中图分类号
TP39 [计算机的应用];
学科分类号
081203 ; 0835 ;
摘要
Hemoglobin concentration is a vital parameter used to detect abnormalities in the human body including anemia and polycythemia. Currently, invasive techniques are used for hemoglobin measurement despite their many disadvantages including discomfort and potential complications for the pregnant, elderly and pediatric patients. This research paper focuses on measuring the hemoglobin concentration without drawing blood. In this study, measurements were obtained from a total of 106 patients and a linear relationship was obtained between hemoglobin concentration measured using the invasive technique (Hb) and the modulation ratio (R) calculated using red light and near-IR spectroscopy. The effect of confounding factors of gender and age were studied in this relationship. Based on the mathematical model developed, a non-invasive screening tool was developed to determine hemoglobin concentration. The device was evaluated using the 22 test subjects. The state-of-the-art hemoglobin measuring techniques do not facilitate continuous and remote monitoring which is essential in a point of care screening device. The proposed non-invasive device has the advantages of prevention of infections, physical pain, and the low operational or maintenance costs while being portable.
引用
收藏
页码:67 / 70
页数:4
相关论文
共 50 条
  • [21] SalivaPrint as a Non-invasive Diagnostic Tool
    Esteves, Eduardo
    Cruz, Igor
    Esteves, Ana Cristina
    Barros, Marlene
    Rosa, Nuno
    PROCEEDINGS OF THE 13TH INTERNATIONAL JOINT CONFERENCE ON BIOMEDICAL ENGINEERING SYSTEMS AND TECHNOLOGIES, VOL 5: HEALTHINF, 2020, : 677 - 682
  • [22] Non-Invasive Detection of Anemia by Occlusion Spectroscopy
    Weinstein, A.
    Herzenstein, O.
    Kononenko, A.
    Gabis, E.
    Korenberg, A.
    Hod, M.
    TRANSFUSION, 2013, 53 : 104A - 104A
  • [23] NON-INVASIVE SCREENING FOR ADRIAMYCIN CARDIOTOXICITY
    MCKILLOP, JH
    LOPEZ, M
    BRISTOW, MR
    GORIS, ML
    CLINICAL RESEARCH, 1980, 28 (02): : A418 - A418
  • [24] Determining the validity of non-invasive hemoglobin testing to detect anemia in postpartum women at a tertiary care centre
    Vermeer, Julie
    Lett, Christine
    Berry, Warren
    Karreman, Erwin
    ANESTHESIA AND ANALGESIA, 2021, 133 (3S_SUPPL) : 38 - 38
  • [25] NON-INVASIVE SCREENING FOR DOWN SYNDROME
    Passi, Gouri Rao
    INDIAN PEDIATRICS, 2015, 52 (08) : 721 - 721
  • [26] NON-INVASIVE SCREENING - THE PROBABILITY OF EVENTS
    Loncar, D.
    Jankovic, S.
    Milovanovic, D.
    Milosevic-Djordjevic, Olivera
    Stojadinovic, M.
    Loncar, S.
    ARCHIVES OF BIOLOGICAL SCIENCES, 2011, 63 (03) : 609 - 615
  • [27] Non-invasive cancer screening for dogs
    Webster, Sophia
    VETERINARY RECORD, 2024, 195 (01) : 16 - 16
  • [28] The economics of non-invasive aneurysm screening
    Alterman, RL
    Drucker, E
    STROKE, 1997, 28 (01) : 198 - 198
  • [29] MICRORNAS IN URINARY SEDIMENTS AS NON-INVASIVE TOOL TO DETECT ACUTE REJECTION AFTER KIDNEY TRANSPLANTATION
    Gielis, Els M.
    Anholts, Jacqueline D. H.
    de Fijter, Hans W.
    Bajema, Ingeborg M.
    Claas, Frans H. J.
    Eikmans, Michael
    HLA, 2016, 87 (04) : 207 - 207
  • [30] MicroRNAs in Urinary Sediments as Non-Invasive Tool to Detect Acute Rejection After Kidney Transplantation
    Gielis, E.
    Anholts, J.
    de Fijter, H.
    Bajema, I.
    Claas, F.
    Eikmans, M.
    AMERICAN JOURNAL OF TRANSPLANTATION, 2016, 16 : 251 - 252