Evaluation of target volume and dose accuracy in intrafractional cases of lung cancer based on 4D-CT and 4D-CBCT images using an in-house dynamic thorax phantom

被引:1
作者
Haqqi, Firyal Dhiyaul [1 ]
Sudarmaji, Arief [1 ]
Wibowo, Wahyu Edy [2 ]
Nasution, Nuruddin [2 ]
Handoko, Handoko [2 ]
Fauzia, Annisa Rahma [2 ]
Qudsi, Jihadil [3 ]
Pawiro, Supriyanto Ardjo [1 ,4 ]
机构
[1] Univ Indonesia, Fac Math & Nat Sci, Dept Phys, Depok, West Java, Indonesia
[2] Univ Indonesia, Cipto Mangunkusumo Gen Hosp, Fac Med, Dept Radiat Oncol, Jakarta, Indonesia
[3] Politekn Med Farma Husada, Dept Med Record & Med Informat, Mataram, West Nusa Tengg, Indonesia
[4] Univ Indonesia, Fac Math & Nat Sci, Dept Phys, Depok City, West Java, Indonesia
关键词
4D-CT; 4D-CBCT; dose evaluation; in-house phantom; volume evaluation; STEREOTACTIC BODY RADIOTHERAPY; MID-VENTILATION; INTENSITY PROJECTION; RADIATION-THERAPY; TUMOR MOTION; MANAGEMENT; RESPIRATION; TRACKING; AVERAGE; CT;
D O I
10.5603/RPOR.a2022.0029
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Background: This study aimed to evaluate the target volume and dose accuracy in intrafraction cases using 4-dimensional imaging modalities and an in-house dynamic thorax phantom. Intrafraction motion can create errors in the definition of target volumes, which can significantly affect the accuracy of radiation delivery. Motion management using 4-dimensional modalities is required to reduce the risk. Materials and methods: Two variations in both breathing amplitude and target size were applied in this study. From these variations, internal target volume (ITVs) contoured in 10 phases of 4D-CT (ITV10), average intensity projection (AIP), and mid-ventilation (Mid-V) images were reconstructed from all 4D-CT datasets as reference images. Free-breathing (FB), augmentation free-breathing (Aug-FB), and static images were also acquired using the 3D-CT protocol for comparisons. In dose evaluations, the 4D-CBCT modality was applied before irradiation to obtain position correction. Then, the dose was evaluated with Gafchromic film EBT3. Results: The ITV10, AIP, and Mid-V provide GTVs that match the static GTV. The AIP and Mid-V reference images allowed reductions in ITVs and PTVs without reducing the range of target movement areas compared to FB and Aug-FB images with varying percentages in the range of 29.17% to 48.70%. In the dose evaluation, the largest discrepancies between the measured and planned doses were 10.39% for the FB images and 9.21% for the Aug-FB images. Conclusion: The 4D-CT modality can enable accurate definition of the target volume and reduce the PTV. Furthermore, 4D-CBCT provides localization images during registration to facilitate position correction and accurate dose delivery.
引用
收藏
页码:360 / 370
页数:11
相关论文
共 26 条
[1]   Evaluation of the influence of breathing on the movement and modeling of lung tumors [J].
Allen, AM ;
Siracuse, KM ;
Hayman, JA ;
Balter, JM .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2004, 58 (04) :1251-1257
[2]  
[Anonymous], 2009, 104 AAPM, DOI [10.37206/104, DOI 10.37206/104]
[3]  
Billett HH, 1967, ANESTHESIOLOGY, V3
[4]   Moving targets in 4D-CTs versus MIP and AIP: comparison of patients data to phantom data [J].
Borm, Kai Joachim ;
Oechsner, Markus ;
Wiegandt, Moritz ;
Hofmeister, Andreas ;
Combs, Stephanie E. ;
Duma, Marciana Nona .
BMC CANCER, 2018, 18
[5]  
Court Laurence, 2010, J Appl Clin Med Phys, V12, P3276
[6]   Management of the interplay effect when using dynamic MLC sequences to treat moving targets [J].
Court, Laurence E. ;
Wagar, Matthew ;
Ionascu, Dan ;
Berbeco, Ross ;
Chin, Lee .
MEDICAL PHYSICS, 2008, 35 (05) :1926-1931
[7]   Validation of Geometric and Dosimetric Accuracy of Edge Accelerator Gating With Electromagnetic Tracking: A Phantom Study [J].
Dai, Zhenhui ;
Zhang, Hua ;
Xie, Yaoqin ;
Zhu, Lin ;
Zhang, Bailin ;
Cai, Chunya ;
Li, Fei ;
Yang, Geng ;
Jin, Huaizhi ;
Wang, Xuetao .
IEEE ACCESS, 2019, 7 :127693-127702
[8]   ITV, mid-ventilation, gating or couch tracking - A comparison of respiratory motion-management techniques based on 4D dose calculations [J].
Ehrbar, Stefanie ;
Johl, Alexander ;
Tartas, Adrianna ;
Stark, Luisa Sabrina ;
Riesterer, Oliver ;
Klock, Stephan ;
Guckenberger, Matthias ;
Tanadini-Lang, Stephanie .
RADIOTHERAPY AND ONCOLOGY, 2017, 124 (01) :80-88
[9]   Six Degrees-of-Freedom Prostate and Lung Tumor Motion Measurements Using Kilovoltage Intrafraction Monitoring [J].
Huang, Chen-Yu ;
Tehrani, Joubin Nasehi ;
Ng, Jin Aun ;
Booth, Jeremy ;
Keall, Paul .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2015, 91 (02) :368-375
[10]   A study on the dosimetric accuracy of treatment planning for stereotactic body radiation therapy of lung cancer using average and maximum intensity projection images [J].
Huang, Long ;
Park, Kwangyoul ;
Boike, Thomas ;
Lee, Pam ;
Papiez, Lech ;
Solberg, Timothy ;
Ding, Chuxiong ;
Timmerman, Robert D. .
RADIOTHERAPY AND ONCOLOGY, 2010, 96 (01) :48-54