Geometric distortion correction of high-resolution 3 T diffusion tensor brain images

被引:68
作者
Ardekani, S
Sinha, U
机构
[1] Univ Calif Los Angeles, Sch Med, Dept Radiol Sci, Los Angeles, CA 90095 USA
[2] Univ Calif Los Angeles, Biomed Engn IDP, Los Angeles, CA USA
关键词
3 T diffusion tensor imaging; geometric distortion; correction nonlinear registration; optic flow; eddy current;
D O I
10.1002/mrm.20651
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Diffusion-weighted images based on echo planar sequences suffer from distortions due to field inhomogeneities from susceptibility differences as well as from eddy currents arising from diffusion gradients. In this paper, a novel approach using nonlinear warping based on optic flow to correct distortions of baseline and diffusion weighted echo planar images (EPI) acquired at 3 T is presented. The distortion correction was estimated by warping the echo planar images to the anatomically correct T-2-weighted fast spin echo images (T2-FSE). A global histogram intensity matching of the T2-FSE precedes the base line EPI image distortion correction. A local intensity-matching algorithm was used to transform labeled T2-FSE regions to match intensities of diffusion-weighted EPI images prior to distortion correction of these images. Evaluation was performed using three methods: (i) visual comparison of overlaid contours, (I!) a global mutual information index, and (iii) a local distance measure between homologous points. Visual assessment and the global index demonstrated a decrease in geometrical distortion and the distance measure showed that distortions are reduced to a subvoxel level. In conclusion, the warping algorithm is effective in reducing geometric distortions, enabling generation of anatomically correct diffusion tensor images at 3 T. Magn Reson Med 54:1163-1171, 2005. (c) 2005 Wiley-Liss, Inc.
引用
收藏
页码:1163 / 1171
页数:9
相关论文
共 26 条
[1]   A model-based method for retrospective correction of geometric distortions in diffusion-weighted EPI [J].
Andersson, JLR ;
Skare, S .
NEUROIMAGE, 2002, 16 (01) :177-199
[2]   How to correct susceptibility distortions in spin-echo echo-planar images: application to diffusion tensor imaging [J].
Andersson, JLR ;
Skare, S ;
Ashburner, J .
NEUROIMAGE, 2003, 20 (02) :870-888
[3]   Correction of eddy current-induced artefacts in diffusion tensor imaging using iterative cross-correlation [J].
Bastin, ME .
MAGNETIC RESONANCE IMAGING, 1999, 17 (07) :1011-1024
[4]   A TECHNIQUE FOR ACCURATE MAGNETIC-RESONANCE-IMAGING IN THE PRESENCE OF FIELD INHOMOGENEITIES [J].
CHANG, H ;
FITZPATRICK, JM .
IEEE TRANSACTIONS ON MEDICAL IMAGING, 1992, 11 (03) :319-329
[5]  
Chen NK, 1999, MAGNET RESON MED, V41, P1206, DOI 10.1002/(SICI)1522-2594(199906)41:6<1206::AID-MRM17>3.0.CO
[6]  
2-L
[7]   An evaluation of the use of magnetic field maps to undistort echo-planar images [J].
Cusack, R ;
Brett, M ;
Osswald, K .
NEUROIMAGE, 2003, 18 (01) :127-142
[8]   Three-dimensional multimodal brain warping using the demons algorithm and adaptive intensity corrections [J].
Guimond, A ;
Roche, A ;
Ayache, N ;
Meunier, J .
IEEE TRANSACTIONS ON MEDICAL IMAGING, 2001, 20 (01) :58-69
[9]   Deviations from the diffusion tensor model as revealed by contour plot visualization using high angular resolution diffusion-weighted imaging (HARDI) [J].
Hirsch, JG ;
Schwenk, SM ;
Rossmanith, C ;
Hennerici, MG ;
Gass, A .
MAGNETIC RESONANCE MATERIALS IN PHYSICS BIOLOGY AND MEDICINE, 2003, 16 (02) :93-102
[10]   Image distortion correction in fMRI: A quantitative evaluation [J].
Hutton, C ;
Bork, A ;
Josephs, O ;
Deichmann, R ;
Ashburner, J ;
Turner, R .
NEUROIMAGE, 2002, 16 (01) :217-240