The elective use of the seven-cell NIR stent in coronary arteries < 2.75 mm in diameter:: Clinical and angiographic results at 6-month follow-up

被引:2
作者
Eccleshall, SC [1 ]
Jones, H [1 ]
Lichfield, M [1 ]
Jordan, PJ [1 ]
Buller, NP [1 ]
Townend, JN [1 ]
机构
[1] Queen Elizabeth Hosp, Dept Cardiol, Birmingham B15 2TH, W Midlands, England
关键词
angioplasty; stent; small vessels;
D O I
10.1002/ccd.1262
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
The outcome of interventional procedures has been improved by the use of coronary stents in vessels > 3.0 mm in diameter. We report a single-center prospective study of elective coronary stenting in 39 consecutive patients with de novo lesions and reference diameters < 2.75 mm. Seven-cell NIR stents were deployed with standard antiplatelet therapy, but without routine use of IIb/IIIa inhibitors or intravascular ultrasound. There was one case of acute stent thrombosis, but no cases of subacute thrombosis. The binary restenosis rate was 27.8% (10/36 lesions) and the target lesion revascularization rate was 19.4%. Symptoms improved markedly as judged by Canadian Cardiovascular Society and questionnaire scores and the use of antianginal therapy. This pilot study suggests that the elective use of coronary stents in vessels < 2.75 mm in diameter is safe with acceptable long-term results. A randomized trial comparing outcomes after stents and balloon angioplasty in small vessels is required. (C) 2001 Wiley-Liss, Inc.
引用
收藏
页码:174 / 179
页数:6
相关论文
共 21 条
[11]   Predictive factors of restenosis after coronary stent placement [J].
Kastrati, A ;
Schomig, A ;
Elezi, S ;
Schuhlen, H ;
Dirschinger, J ;
Hadamitzky, M ;
Wehinger, A ;
Hausleiter, J ;
Walter, H ;
Neumann, FJ .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1997, 30 (06) :1428-1436
[12]  
Keane D, 1996, Semin Interv Cardiol, V1, P255
[13]   QUALITY-OF-LIFE IN PATIENTS TREATED WITH ATRIOVENTRICULAR SYNCHRONOUS PACING COMPARED TO RATE MODULATED VENTRICULAR PACING - A LONG-TERM, DOUBLE-BLIND, CROSSOVER STUDY [J].
LINDEEDELSTAM, C ;
NORDLANDER, R ;
UNDEN, AL ;
ORTHGOMER, K ;
RYDEN, L .
PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 1992, 15 (10) :1467-1476
[14]   Intravascular ultrasound to discern device-specific effects and mechanisms of restenosis [J].
Mintz, GS ;
Popma, JJ ;
Hong, MK ;
Pichard, AD ;
Kent, KM ;
Satler, LF ;
Leon, MB .
AMERICAN JOURNAL OF CARDIOLOGY, 1996, 78 :18-22
[15]  
Reiber J H, 1984, IEEE Trans Med Imaging, V3, P131, DOI 10.1109/TMI.1984.4307669
[16]  
REIBER J H C, 1989, Medicamundi, V34, P89
[17]   INTRACORONARY STENTING FOR ACUTE AND THREATENED CLOSURE COMPLICATING PERCUTANEOUS TRANSLUMINAL CORONARY ANGIOPLASTY [J].
ROUBIN, GS ;
CANNON, AD ;
AGRAWAL, SK ;
MACANDER, PJ ;
DEAN, LS ;
BAXLEY, WA ;
BRELAND, J .
CIRCULATION, 1992, 85 (03) :916-927
[18]   RELATION OF THROMBOTIC OCCLUSION OF CORONARY STENTS TO THE INDICATION FOR STENTING, STENT SIZE, AND ANTICOAGULATION [J].
ROZENMAN, Y ;
LOTAN, C ;
MOSSERI, M ;
GOTSMAN, MS .
AMERICAN JOURNAL OF CARDIOLOGY, 1995, 75 (01) :84-85
[19]   Efficacy of coronary stenting versus balloon angioplasty in small corollary arteries [J].
Savage, MP ;
Fischman, DL ;
Rake, R ;
Leon, MB ;
Schatz, RA ;
Penn, I ;
Nobuyoshi, M ;
Moses, J ;
Hirshfeld, J ;
Heuser, R ;
Baim, D ;
Cleman, M ;
Brinker, J ;
Gebhardt, S ;
Goldberg, S .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1998, 31 (02) :307-311
[20]   Randomised comparison of implantation of heparin-coated stents with balloon angioplasty in selected patients with coronary artery disease (Benestent II) [J].
Serruys, PW ;
van Hout, B ;
Bonnier, H ;
Legrand, V ;
Garcia, E ;
Macaya, C ;
Sousa, E ;
van der Giessen, W ;
Colombo, A ;
Seabra-Gomes, R ;
Kiemeneij, F ;
Ruygrok, P ;
Ormiston, J ;
Emanuelsson, H ;
Fajadet, J ;
Haude, M ;
Klugmann, S ;
Morel, MA .
LANCET, 1998, 352 (9129) :673-681