Creatinine determination in serum by capillary electrophoresis

被引:23
作者
Paroni, R
Fermo, I
Cighetti, G
Ferrero, CA
Carobene, A
Ceriotti, F
机构
[1] Univ Milan, Dept Med Surg & Dent Sci, I-20142 Milan, Italy
[2] Univ Milan, Lab Seperat Tech, IRCCS H San Raffaele, Milan, Italy
[3] Univ Milan, Dept Med Chem Biochem & Biotechnol, I-20122 Milan, Italy
[4] San Raffaele SpA, Diagnost & Ric, Milan, Italy
关键词
capillary electrophoresis; creatinine; high-performance liquid chromatography; serum;
D O I
10.1002/elps.200305687
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Creatinine in human serum was separated in a fused-silica capillary with H3PO4 (75 mmol/L, pH 2.5) as BGE, followed by UV detection at 200 nm. Serum with methylimidazole-added as internal standard was deproteinized with acetonitrile and the supernatant, after dilution with water was injected at pressure mode. Creatinine and methylimidazole were baseline-resolved in 6.5 min. Linearity in the 0-880 mumol/L range gave an r(2) greater than or equal to 0.998, recovery was 102 +/- 2.8% (n = 6). Enzymatic breakdown with creatininase confirmed that serum does not interfere. The within-day and between-days coefficient of variation (CV) were less than or equal to 2.16 and 2.7%, respectively. The accuracy, determined for lyophilized samples by isotope dilution gas chromatography-mass spectrometry was less than or equal to +/- 2.0%. The results were compared with HPLC for 32 lyophilized samples and on 27 serum pools. Capillary electrophoresis, rapid and inexpensive, seems a promising alternative to high-performance liquid chromatography (HPLC) for creatinine determination in human serum.
引用
收藏
页码:463 / 468
页数:6
相关论文
共 27 条
[1]   Increase of sample load without peak deterioration by careful selection of electrolyte in capillary zone electrophoresis [J].
Andersson, EKM ;
Hägglund, I .
JOURNAL OF CHROMATOGRAPHY A, 2002, 953 (1-2) :227-237
[2]   Analysis of creatine and creatinine in urine by capillary electrophoresis [J].
Burke, DG ;
MacLean, PG ;
Walker, RA ;
Dewar, PJ ;
Smith-Palmer, T .
JOURNAL OF CHROMATOGRAPHY B, 1999, 732 (02) :479-485
[3]  
Carobene A, 1997, CLIN CHEM, V43, P1342
[4]   High-throughput multi-analyte screening for renal disease using capillary electrophoresis [J].
Clark, EA ;
Fanguy, JC ;
Henry, CS .
JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2001, 25 (5-6) :795-801
[5]   Simultaneous determination of the urinary metabolites of toluene, xylene and styrene using high-performance capillary electrophoresis - Comparison with high-performance liquid chromatography [J].
Fujii, T ;
Kawabe, S ;
Horike, T ;
Taguchi, T ;
Ogata, M .
JOURNAL OF CHROMATOGRAPHY B, 1999, 730 (01) :41-47
[6]  
Gatti R, 1999, ELECTROPHORESIS, V20, P2917, DOI 10.1002/(SICI)1522-2683(19991001)20:14<2917::AID-ELPS2917>3.0.CO
[7]  
2-W
[8]   Approved IFCC reference method for the measurement of HbA1c in human blood [J].
Jeppsson, JO ;
Kobold, U ;
Barr, J ;
Finke, A ;
Hoelzel, W ;
Hoshino, T ;
Miedema, K ;
Mosca, A ;
Mauri, P ;
Paroni, R ;
Thienpont, L ;
Umemoto, M ;
Weykamp, C .
CLINICAL CHEMISTRY AND LABORATORY MEDICINE, 2002, 40 (01) :78-89
[9]  
Kochansky CJ, 2001, ELECTROPHORESIS, V22, P2518, DOI 10.1002/1522-2683(200107)22:12<2518::AID-ELPS2518>3.0.CO
[10]  
2-A