A Monte Carlo approach to lung dose calculation in small fields used in intensity modulated radiation therapy and stereotactic body radiation therapy

被引:12
|
作者
Mesbahi, Asghar [1 ,2 ]
Dadgar, Habib [1 ]
Ghareh-Aghaji, Nahideh [3 ]
Mohammadzadeh, Mohammad [2 ]
机构
[1] Tabriz Univ Med Sci, Sch Med, Dept Med Phys, Tabriz, Iran
[2] Tabriz Univ Med Sci, Imam Hosp, Dept Radiat Oncol, Tabriz, Iran
[3] Tabriz Univ Med Sci, Paramed Sch, Dept Radiol, Tabriz, Iran
关键词
Electronic disequilibrium; monte carlo calculations; radiotherapy of lung; small field dosimetry; ELECTRONIC DISEQUILIBRIUM; IMRT TREATMENT; ALGORITHMS; SBRT;
D O I
10.4103/0973-1482.137989
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Aims: In the current study, the effect of electronic disequilibrium on lung dose with small photon beams was verified. Materials and Methods: The central axis absorbed dose in lung phantom was calculated by Monte Carlo (MC) method. The 6 and 18 MV photon beams of Varian Clinac 2100EX were simulated using MCNPX MC Code (Los Alamos national lab, USA). The MC model was used to calculate the depth doses water and low density water resembling the soft-tissue and lung, respectively. Four small field sizes including 0.5 cm (2) x 0.5 cm (2) , 1 cm (2) x 1 cm (2) , 2 cm (2) x 2 cm (2) , and 3 cm (2) x 3 cm (2) were used in this study. Results: Percentage of dose reduction in lung region relative to homogenous phantom for 6 MV photon beam were 44.6%, 39%, 13%, and 7% for 0.5 cm (2) x 0.5 cm (2) , 1 cm (2) x 1 cm (2) , 2 cm (2) x 2 cm (2) , and 3 cm (2) x 3 cm (2) fields, respectively. For 18 MV photon beam, the results were found to be 82%, 69%, 46%, and 25.8% for the same field sizes, respectively. The solid tumor dose inside lung was reduced considerably between 17% and 35% for 18 MV beam, while there was only 9% dose reduction for tumor dose for 0.5 and 1 cm field sizes. Conclusion: Our study showed that the dose reduction with small fields in the lung was very enormous. Thus, inaccurate prediction of absorbed dose inside lung and also lung soft-tissue interfaces with small photon beams may lead to critical consequences for treatment outcome.
引用
收藏
页码:896 / 902
页数:7
相关论文
共 50 条
  • [1] GATE Monte Carlo approach to heterogeneity dose distribution in small fields used in radiation therapy
    Elcadi, Z. A.
    El Moussaoui, M.
    Aouadi, S.
    Sukumaran, R.
    Hammoud, R.
    Al-Hammadi, N.
    Toufique, Y.
    Bouhali, O.
    BIOMEDICAL PHYSICS & ENGINEERING EXPRESS, 2024, 10 (03)
  • [2] Monte Carlo Dose Evaluation for Pancreatic Stereotactic Body Radiation Therapy
    Gan, H.
    Zheng, D.
    Lei, Y.
    Li, S.
    Zhang, Q.
    Zhou, S.
    Li, J.
    Lin, C.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2014, 90 : S363 - S363
  • [3] Impact of Lack of Coverage Established By Monte Carlo Dose Calculation on Small Island Lung Tumors Treated With Stereotactic Body Radiation Therapy (SBRT)
    Tanguy, R.
    Sunyach, M. P.
    Carrie, C.
    Zahra-Ayadi, M.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2015, 93 (03): : E438 - E438
  • [4] The impact of Monte Carlo dose calculations on intensity-modulated radiation therapy
    Siebers, JV
    Keall, PJ
    Mohan, R
    ADVANCED MONTE CARLO FOR RADIATION PHYSICS, PARTICLE TRANSPORT SIMULATION AND APPLICATIONS, 2001, : 205 - 210
  • [5] Validation of a commercial Monte Carlo code used for stereotactic radiosurgery and stereotactic body radiation therapy
    Milroy, D.
    Dos Santos, G.
    Seuntjens, J.
    Patrocinio, H.
    MEDICAL PHYSICS, 2012, 39 (07) : 4620 - 4620
  • [6] Charcterization of mean lung dose in Stereotactic Body Radiation Therapy (SBRT) by direct measurement in anthropomorphic phantom and by Monte Carlo calculation
    Salter, B
    Rassiah, P
    Tanyi, J
    Cheng, C
    Fuss, M
    MEDICAL PHYSICS, 2004, 31 (06) : 1720 - 1720
  • [7] Characterization of target dose in Stereotactic Body Radiation Therapy (SBRT) of lung by direct measurment in anthropomorphic phantom and by Monte Carlo calculation
    Salter, B
    Rassiah, P
    Tanyi, J
    Cheng, C
    Fuss, M
    MEDICAL PHYSICS, 2004, 31 (06) : 1716 - 1716
  • [8] Intrafraction Motion in Stereotactic Body Radiation Therapy for Non-Small Cell Lung Cancer: Intensity Modulated Radiation Therapy Versus Volumetric Modulated Arc Therapy
    Rossi, Maddalena M. G.
    Peulen, Heike M. U.
    Belderbos, Jose S. A.
    Sonke, Jan-Jakob
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2016, 95 (02): : 835 - 843
  • [9] Characterization of doses in stereotactic body radiation therapy (SBRT) via Monte Carlo calculation
    Salter, B
    Rasiah, P
    Fuss, M
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2005, 63 (02): : S539 - S540
  • [10] Monte Carlo evaluation of Acuros XB dose calculation Algorithm for intensity modulated radiation therapy of nasopharyngeal carcinoma
    Yeh, Peter C. Y.
    Lee, C. C.
    Chao, T. C.
    Tung, C. J.
    RADIATION PHYSICS AND CHEMISTRY, 2017, 140 : 419 - 422