Differential Effect of Total Knee Arthroplasty on Valgus and Varus Knee Biomechanics During Gait

被引:6
作者
Rodriguez, Jose A. [1 ]
Bas, Marcel A. [1 ]
Orishimo, Karl F. [2 ]
Robinson, Jonathan [1 ]
Nicholas, Stephen J. [1 ]
机构
[1] North Shore LIJ Hlth Syst, Lenox Hill Hosp, Dept Orthopaed Surg, New York, NY USA
[2] North Shore LIJ Hlth Syst, Lenox Hill Hosp, Dept Orthopaed Surg, Nicholas Inst Sports Med & Athlet Trauma, New York, NY USA
关键词
knee arthroplasty; knee biomechanics; gait; total knee arthroplasty; valgus; varus; DISEASE PROGRESSION; TIBIAL OSTEOTOMY; DYNAMIC LOAD; OSTEOARTHRITIS; REPLACEMENT; WALKING; MOMENT; ALIGNMENT; PATTERN;
D O I
10.1016/j.arth.2016.06.061
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Background: Total knee arthroplasty and its relation to gait abduction or adduction moment has not been fully described. Methods: Gait analysis was performed on 25 patients (27 knees) preoperatively, 6 months and 1 year after total knee arthroplasty. Reflective markers were placed on the lower extremity, and motion data were collected at 60 Hz using 6 infrared cameras. Ground reaction forces were recorded at 960 Hz with a force plate. Stance phase was divided into braking and propulsive phases. Coronal knee angles and moments were calculated. Repeated-measures analysis of variance was used to compare frontal plane knee impulse over time and between the braking and propulsive phases of stance. Results: In varus knees, static alignment was corrected from 2.2 degrees varus to 3.3 degrees valgus and in valgus knees from 15.2 degrees valgus to 2.7 degrees valgus (P <.010). Braking phase adduction impulse decreased from 0.145 to 0.111 at 6 months but increased to 0.126 Nm/kg s (P >.05) at 1 year. Propulsive phase impulse changed from 0.129 to 0.085 and persisted at 1 year. Impulse changed from 0.01 (abduction) to 0.11 Nm/kg s (adduction) at 6 months and persisted (P = .01). Conclusion: Restoration of anatomic alignment and soft tissue balancing changes the lateral loading conditions of valgus knees. Both cases, between 6 months and 1 year, increased peak moment. (C) 2016 Elsevier Inc. All rights reserved.
引用
收藏
页码:S248 / S253
页数:6
相关论文
共 33 条
[1]  
Ahlbck S., 1968, Acta Radiol Diagn (Stockh), P7
[2]   Gait after Unilateral Total Knee Arthroplasty: Frontal Plane Analysis [J].
Alnahdi, Ali H. ;
Zeni, Joseph A. ;
Snyder-Mackler, Lynn .
JOURNAL OF ORTHOPAEDIC RESEARCH, 2011, 29 (05) :647-652
[3]  
Andriacchi T P, 1986, J Arthroplasty, V1, P211, DOI 10.1016/S0883-5403(86)80033-X
[4]  
ANDRIACCHI TP, 1994, ORTHOP CLIN N AM, V25, P395
[5]   Increased knee joint loads during walking are present in subjects with knee osteoarthritis [J].
Baliunas, AJ ;
Hurwitz, DE ;
Ryals, AB ;
Karrar, A ;
Case, JP ;
Block, JA ;
Andriacchi, TP .
OSTEOARTHRITIS AND CARTILAGE, 2002, 10 (07) :573-579
[6]   2003 Hap Paul Award paper of the international society for technology in arthroplasty [J].
Banks, SA ;
Hodge, WA .
JOURNAL OF ARTHROPLASTY, 2004, 19 (07) :809-816
[7]   Muscle activation pattern and gait biomechanics after total knee replacement [J].
Benedetti, MG ;
Catani, F ;
Bilotta, TW ;
Marcacci, M ;
Mariani, E ;
Giannini, S .
CLINICAL BIOMECHANICS, 2003, 18 (09) :871-876
[8]   A comparison of isokinetic strength testing and gait analysis in patients with posterior cruciate-retaining and substituting knee arthroplasties [J].
Bolanos, AA ;
Colizza, WA ;
McCann, PD ;
Gotlin, RS ;
Wootten, ME ;
Kahn, BA ;
Insall, JN .
JOURNAL OF ARTHROPLASTY, 1998, 13 (08) :906-915
[9]  
CAMERON HU, 1994, CLIN ORTHOP RELAT R, P29
[10]   Functional analysis of cemented medial unicompartmental knee arthroplasty [J].
Chassin, EP ;
Mikosz, RP ;
Andriacchi, TP ;
Rosenberg, AG .
JOURNAL OF ARTHROPLASTY, 1996, 11 (05) :553-559