Radiation Safety in Pediatric Orthopaedics

被引:9
作者
Caird, Michelle S. [1 ]
机构
[1] Univ Michigan, Dept Orthopaed Surg, 1540 E Hosp Dr, Ann Arbor, MI 48109 USA
关键词
radiation exposure; ionizing radiation; medical imaging; computed tomography; fluoroscopy; C-ARM FLUOROSCOPY; PEDICLE SCREW INSERTION; IONIZING-RADIATION; OCCUPATIONAL-EXPOSURE; SURGEON; SCOLIOSIS; SPINE; RADIOGRAPHY; REDUCTION; FRACTURES;
D O I
10.1097/BPO.0000000000000542
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Patients, surgeons, and staff are exposed to ionizing radiation in pediatric orthopaedic surgery from diagnostic studies and imaging associated with procedures. Estimating radiation dose to pediatric patients is based on complex algorithms and dose to surgeons and staff is based on dosimeter monitoring. Surgeons can decrease radiation exposure to patients with careful and thoughtful ordering of diagnostic studies and by minimizing exposure intraoperatively. Surgeon and staff radiation exposure can be minimized with educational programs, proper shielding and positioning intraoperatively, and prudent use of intraoperative imaging. Overall, better awareness among pediatric orthopaedic surgeons of our role in radiation exposure can lead to improvements in radiation safety.
引用
收藏
页码:S34 / S36
页数:3
相关论文
共 40 条
[31]   MEDICAL RADIATION PROTECTION IN NEXT DECADE [J].
Rehani, Madan M. ;
Vano, Eliseo .
RADIATION PROTECTION DOSIMETRY, 2011, 147 (1-2) :52-53
[32]   EXPOSURE OF THE ORTHOPEDIC SURGEON TO RADIATION [J].
SANDERS, R ;
KOVAL, KJ ;
DIPASQUALE, T ;
SCHMELLING, G ;
STENZLER, S ;
ROSS, E .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1993, 75A (03) :326-330
[33]   Occupational radiation exposure to the surgeon [J].
Singer, G .
JOURNAL OF THE AMERICAN ACADEMY OF ORTHOPAEDIC SURGEONS, 2005, 13 (01) :69-76
[34]   Assessment of mobility after multi-level surgery for cerebral palsy [J].
Graham, H. K. ;
Harvey, A. .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 2007, 89B (08) :993-994
[35]   Radiation dose for pedicle screw insertion -: Fluoroscopic method versus computer-assisted surgery [J].
Slomczykowski, M ;
Roberto, M ;
Schneeberger, P ;
Ozdoba, C ;
Vock, P .
SPINE, 1999, 24 (10) :975-982
[36]   2013 Young Investigator Award Winner: How Safe Is Lateral Lumbar Interbody Fusion for the Surgeon? A Prospective In Vivo Radiation Exposure Study [J].
Taher, Fadi ;
Hughes, Alexander P. ;
Sama, Andrew A. ;
Zeldin, Roseann ;
Schneider, Robert ;
Holodny, Edward I. ;
Lebl, Darren R. ;
Fantini, Gary A. ;
Nguyen, Joseph ;
Cammisa, Frank P. ;
Girardi, Federico P. .
SPINE, 2013, 38 (16) :1386-1392
[37]   Occupational exposure from common fluoroscopic projections used in orthopaedic surgery [J].
Theocharopoulos, N ;
Perisinakis, K ;
Damilakis, J ;
Papadokostakis, G ;
Hadjipavlou, A ;
Gourtsoyiannis, N .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2003, 85A (09) :1698-1703
[38]   Radiation exposure with use of the inverted-c-arm technique in upper-extremity surgery [J].
Tremains, MR ;
Georgiadis, GM ;
Dennis, MJ .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2001, 83A (05) :674-678
[39]   Occupational radiation exposure and pregnancy in orthopaedics [J].
Uzoigwe, C. E. ;
Middleton, R. G. .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 2012, 94B (01) :23-27
[40]   Radiation in the workplace-a review of studies of the risks of occupational exposure to ionising radiation [J].
Wakeford, Richard .
JOURNAL OF RADIOLOGICAL PROTECTION, 2009, 29 (2A) :A61-A79