Radiation Safety in Pediatric Orthopaedics

被引:9
作者
Caird, Michelle S. [1 ]
机构
[1] Univ Michigan, Dept Orthopaed Surg, 1540 E Hosp Dr, Ann Arbor, MI 48109 USA
关键词
radiation exposure; ionizing radiation; medical imaging; computed tomography; fluoroscopy; C-ARM FLUOROSCOPY; PEDICLE SCREW INSERTION; IONIZING-RADIATION; OCCUPATIONAL-EXPOSURE; SURGEON; SCOLIOSIS; SPINE; RADIOGRAPHY; REDUCTION; FRACTURES;
D O I
10.1097/BPO.0000000000000542
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Patients, surgeons, and staff are exposed to ionizing radiation in pediatric orthopaedic surgery from diagnostic studies and imaging associated with procedures. Estimating radiation dose to pediatric patients is based on complex algorithms and dose to surgeons and staff is based on dosimeter monitoring. Surgeons can decrease radiation exposure to patients with careful and thoughtful ordering of diagnostic studies and by minimizing exposure intraoperatively. Surgeon and staff radiation exposure can be minimized with educational programs, proper shielding and positioning intraoperatively, and prudent use of intraoperative imaging. Overall, better awareness among pediatric orthopaedic surgeons of our role in radiation exposure can lead to improvements in radiation safety.
引用
收藏
页码:S34 / S36
页数:3
相关论文
共 40 条
[1]   Dose distribution at radiographic examination of the spine in pediatric radiology [J].
Almen, AJ ;
Mattsson, S .
SPINE, 1996, 21 (06) :750-756
[2]   Scattered radiation during fixation of hip fractures - Is distance alone enough protection? [J].
Alonso, JA ;
Shaw, DL ;
Maxwell, A ;
McGill, GP ;
Hart, GC .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 2001, 83B (06) :815-818
[3]   Intraoperative C-Arm Radiation Affecting Factors and Reduction by an Intervention Program [J].
Bar-On, Elhanan ;
Weigl, Daniel Martin ;
Becker, Tali ;
Katz, Kalman ;
Konen, Osnat .
JOURNAL OF PEDIATRIC ORTHOPAEDICS, 2010, 30 (04) :320-323
[4]   Establishing the radiation risk from fluoroscopic-assisted arthroscopic surgery of the hip [J].
Budd, Henry ;
Patchava, Anushka ;
Khanduja, Vikas .
INTERNATIONAL ORTHOPAEDICS, 2012, 36 (09) :1803-1806
[5]  
Burns S, 2013, J BONE JOINT SURG AM, V95A, P1307, DOI [10.2106/JBJS.L.00893, 10.2106/JBJS.L00893]
[6]   The Insertion of Intramedullary Nail Locking Screws Without Fluoroscopy: A Faster and Safer Technique [J].
Chan, Daniel S. ;
Burris, Richard B. ;
Erdogan, Murat ;
Sagi, H. Claude .
JOURNAL OF ORTHOPAEDIC TRAUMA, 2013, 27 (07) :363-366
[7]   RADIATION HAZARDS IN SCOLIOSIS MANAGEMENT [J].
DRUMMOND, D ;
RANALLO, F ;
LONSTEIN, J ;
BROOKS, HL ;
CAMERON, J .
SPINE, 1983, 8 (07) :741-748
[8]  
DUTKOWSKY JP, 1990, J PEDIATR ORTHOPED, V10, P532
[9]   Can Radiation Exposure to the Surgeon Be Reduced With Freehand Pedicle Screw Fixation Technique in Pediatric Spinal Deformity Correction? A Prospective Multicenter Study [J].
Erken, H. Yener ;
Burc, Halil ;
Saka, Gursel ;
Akmaz, Ibrahim ;
Aydogan, Mehmet .
SPINE, 2014, 39 (06) :521-525
[10]   Protective aprons in imaging departments: manufacturer stated lead equivalence values require validation [J].
Finnerty, M ;
Brennan, PC .
EUROPEAN RADIOLOGY, 2005, 15 (07) :1477-1484