Ocular pulse amplitude in different types of glaucoma using dynamic contour tonometry: Diagnosis and follow-up of glaucoma

被引:8
作者
Cheng, Lingyan [1 ]
Ding, Yuzhi [2 ]
Duan, Xuanchu [3 ]
Wu, Zhifeng [1 ]
机构
[1] Nanjing Med Univ, Wuxi Peoples Hosp 2, Dept Ophthalmol, 68 Zhongshan Rd, Wuxi 214000, Jiangsu, Peoples R China
[2] Southeast Univ, Sch Med, Zhongda Hosp, Dept Ophthalmol, Nanjing 210009, Jiangsu, Peoples R China
[3] Cent S Univ, Xiangya Hosp 2, Dept Ophthalmol, Changsha 410008, Hunan, Peoples R China
关键词
ocular pulse amplitude; dynamic contour tonometry; intraocular pressure; glaucoma; OPEN-ANGLE GLAUCOMA; INTRAOCULAR-PRESSURE; CORNEAL THICKNESS; TENSION GLAUCOMA;
D O I
10.3892/etm.2017.5074
中图分类号
R-3 [医学研究方法]; R3 [基础医学];
学科分类号
1001 ;
摘要
The aim of the present study was to compare the ocular pulse amplitude (OPA) in patients with different types of glaucoma using dynamic contour tonometry (DCT), to evaluate ocular and systemic factors associated with the OPA and to verify whether OPA measured by DCT is an independent predictor for glaucoma diagnosis. A total of 217 eyes of 217 participants in the following five groups were included in this cross-sectional study: Chronic angle closure glaucoma (CACG), primary open angle glaucoma, normal tension glaucoma (NTG), suspected open angle glaucoma (SOAG) and normal control (NC). The following tests were simultaneously performed during a single visit: Intra-ocular pressure (IOP), OPA, cup-to-disk (C/D) ratio, mean damage (MD) and loss variance (LV). OPAs were compared in each group. The association between OPA and IOP, age, C/D ratio, MD and LV was detected. OPA analysis prior to and after trabeculectomy was also performed to assess its prognostic value. Among the 217 individuals, the OPA was consistent with the IOP, both measured by DCT, along with the MD and LV. Patients with CACG and SOAG had higher OPA values than those with NTG and normal controls. Compared with patients aged >30 years, the OPA was significantly lower in younger patients, while they may not have been affected by different C/D ratios. After trabeculectomy, the OPA had significantly decreased compared with the values prior to surgery. In conclusion, the present study showed that the OPA is correlated with the IOP determined by DCT. CACG and SOAG patients had higher OPA values than patients with other types of glaucoma. OPA measured by DCT may be a predictor for glaucoma diagnosis and prognosis.
引用
收藏
页码:4148 / 4152
页数:5
相关论文
共 21 条
[1]   Can dynamic contour tonometry and ocular pulse amplitude help to detect severe cardiovascular pathologies? [J].
Bertelmann, T. ;
Langanke, S. ;
Potstawa, M. ;
Strempel, I. .
CLINICAL OPHTHALMOLOGY, 2014, 8 :1317-1321
[2]  
Brandt James D, 2004, Curr Opin Ophthalmol, V15, P85, DOI 10.1097/00055735-200404000-00004
[3]   Corneal structure and biomechanics: impact on the diagnosis and management of glaucoma [J].
Brown, Kimberly E. ;
Congdon, Nathan G. .
CURRENT OPINION IN OPHTHALMOLOGY, 2006, 17 (04) :338-343
[4]   Assessment of true intraocular pressure: The gap between theory and practical data [J].
Chihara, Etsuo .
SURVEY OF OPHTHALMOLOGY, 2008, 53 (03) :203-218
[5]   Factors affecting ocular pulse amplitude in eyes with open angle glaucoma and glaucoma-suspect eyes [J].
Choi, Jaewan ;
Lee, Jooeun ;
Park, Sung B. ;
Lee, Kyung S. ;
Sung, Kyung R. ;
Kook, Michael S. .
ACTA OPHTHALMOLOGICA, 2012, 90 (06) :552-558
[6]   Optic disc morphology in myopic primary open-angle glaucoma [J].
Jonas, JB ;
Dichtl, A .
GRAEFES ARCHIVE FOR CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 1997, 235 (10) :627-633
[7]   The ocular pulse amplitude at different intraocular pressure: a prospective study [J].
Knecht, Pascal Bruno ;
Bosch, Martina Monika ;
Michels, Stephan ;
Mannhardt, Soenke ;
Schmid, Ursina ;
Bosch, Martin Albert ;
Menke, Marcel Nico .
ACTA OPHTHALMOLOGICA, 2011, 89 (05) :E466-E471
[8]   Correlation between intraocular pressure, central corneal thickness, stage of glaucoma, and demographic patient data -: Prospective analysis of biophysical parameters in tertiary glaucoma practice populations [J].
Kniestedt, C ;
Lin, S ;
Choe, J ;
Nee, M ;
Bostrom, A ;
Stürmer, J ;
Stamper, RL .
JOURNAL OF GLAUCOMA, 2006, 15 (02) :91-97
[9]  
Mittag T W, 1994, Surv Ophthalmol, V38 Suppl, pS183, DOI 10.1016/0039-6257(94)90065-5
[10]   Physiological diurnal variability and characteristics of the ocular pulse amplitude (OPA) with the dynamic contour tonometer (DCT-Pascal®) [J].
Pourjavan S. ;
Boëlle P.-Y. ;
Detry-Morel M. ;
De Potter P. .
International Ophthalmology, 2007, 27 (6) :357-360