Flow injection flame atomic absorption determination of Cu, Mn and Zn partitioning in seawater by on-line room temperature sonolysis and minicolumn chelating resin methodology

被引:12
作者
Yebra-Biurrun, M. C. [1 ]
Carro-Marino, N. [2 ]
机构
[1] Univ Santiago de Compostela, Fac Chem, Dept Analyt Chem Nutr & Bromatol, Santiago De Compostela 15782, Spain
[2] Inst Tecnol Control Medio Marino Galicia INTECMAR, Conselleria Do Mar 36611, Vilagarcia Arou, Spain
关键词
Sonolysis; Preconcentration; Flow injection; Cu; Mn and Zn partitioning; Flame atomic absorption spectrometry; Seawater; ULTRASOUND-ASSISTED EXTRACTION; TRACE-METAL DISTRIBUTIONS; PORT-JACKSON ESTUARY; THIN-FILMS TECHNIQUE; DIFFUSIVE GRADIENTS; FIELD PRECONCENTRATION; SPECIATION; SAMPLES; WATERS; SYSTEM;
D O I
10.1016/j.talanta.2010.09.045
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A flow-injection system is developed for Cu, Mn and Zn partitioning in seawater by flame atomic absorption spectrometry. The first approach is where the trace metal species are fractionated in situ, but analysis is performed by using a flow injection manifold in the laboratory. This operational mode is used for the determination of the dissolved labile metallic fraction and is based on the elution of this fraction from a minicolumn packed with a chelating resin containing iminodiacetic acid groups (Serdolit Chelite Che) loaded in situ with the sample. The second is used for the determination of total dissolved concentrations of trace metals. This last mode is based on the retention/preconcentration of total dissolved metals on the chelating resin after on-line sonolysis of seawater samples acidified with diluted nitric acid to breakdown the metal-organic matter complexes. The figures of merit for Cu, Mn and Zn determinations in both fractions are given and the obtained values are discussed. The fractionation scheme is applied to the analysis of coastal seawater samples collected in Galicia (Northwest, Spain). The results of fractionation showed that Mn and Zn are mainly in the labile fraction, while Cu was mainly present in the organic fraction. (C) 2010 Elsevier B.V. All rights reserved.
引用
收藏
页码:425 / 430
页数:6
相关论文
共 52 条
[1]   Determination of total and labile fraction of metals in seawater using solid phase extraction and inductively coupled plasma atomic emission spectrometry (ICP-AES) [J].
Abbasse, G ;
Ouddane, B ;
Fischer, JC .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2002, 17 (10) :1354-1358
[2]   UV digestion of seawater samples prior to the determination of copper using flow injection with chemiluminescence detection [J].
Achterberg, EP ;
Braungardt, CB ;
Sandford, RC ;
Worsfold, PJ .
ANALYTICA CHIMICA ACTA, 2001, 440 (01) :27-36
[3]   Performance evaluation of two chelating ion-exchange sorbents for the fractionation of labile and inert metal species from aquatic media [J].
Alvarez, MB ;
Malla, ME ;
Batistoni, DA .
ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2004, 378 (02) :438-446
[4]   Distribution of dissolved species and suspended particulate copper in an intertidal ecosystem affected by copper mine tailings in Northern Chile [J].
Andrade, Santiago ;
Moffett, James ;
Correa, Juan A. .
MARINE CHEMISTRY, 2006, 101 (3-4) :203-212
[5]  
[Anonymous], 2002, STATGRAPHICS PLUS V
[6]   A rapid Chelex column method for the determination of metal speciation in natural waters [J].
Bowles, KC ;
Apte, SC ;
Batley, GE ;
Hales, LT ;
Rogers, NJ .
ANALYTICA CHIMICA ACTA, 2006, 558 (1-2) :237-245
[7]  
Cancela-Pérez S, 2005, ATOM SPECTROSC, V26, P110
[8]   Room temperature sonolysis-based advanced oxidation process for degradation of organomercurials: Application to determination of inorganic and total mercury in waters by flow injection-cold vapor atomic absorption spectrometry [J].
Capelo, JL ;
Lavilla, I ;
Bendicho, C .
ANALYTICAL CHEMISTRY, 2000, 72 (20) :4979-4984
[9]   Ultrasound in analytical chemistry [J].
Capote, F. Priego ;
Luque de Castro, M. D. .
ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2007, 387 (01) :249-257
[10]   Determination of trace metals in urine with an on-line ultrasound-assisted digestion system combined with a flow-injection preconcentration manifold coupled to flame atomic absorption spectrometry [J].
Cespon-Romero, R. M. ;
Yebra-Biurrun, M. C. .
ANALYTICA CHIMICA ACTA, 2008, 609 (02) :184-191