A clinical evaluation of cobalt-chromium metal-ceramic fixed partial dentures an crowns: A three- to seven-year retrospective study

被引:78
作者
Eliasson, Alf
Arnelund, Carl-Fredrik
Johansson, Anders
机构
[1] Postgrad Dent Educ Ctr, Dept Prosthet Dent, SE-70111 Orebro 1, Sweden
[2] Univ Bergen, Fac Dent, Dept Oral Sci Prosthodont, N-5020 Bergen, Norway
关键词
D O I
10.1016/S0022-3913(07)60032-8
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Statement of problem. In severely compromised dentition, loading of long-span and cantilever metal-ceramic fixed partial dentures (FPDs) could result in framework deformation and porcelain fractures. The use of cobalt-chromium (Co-Cr) alloys may be advantageous, but there is little information on the longevity of, and complications with, prostheses made with these alloys. Purpose. The aim of this retrospective study was to report the survival and complication rates of Co-Cr metal-ceramic FPDs and crowns followed over a 3- to 7-year period. Material and methods. The study included 42 patients with a total of 51 FPDs and 12 single crowns assigned to 1 of 3 groups. The 3 groups comprised patients with abutment teeth with a questionable prognosis (n=10), advanced chronic periodontitis (n=19), or abutment teeth with a positive prognosis (n=13). The FPDs had a mean of 9.7 units (range of 3-14). Of the FPDs, 32 were provided with a cantilever on 1 side (n=24) or both sides (n=8). The mean observation time was 51 months (range of 28-82). All patients were examined by 2 independent prosthodontists using the California Dental Association (CDA) assessment system for evaluation. One-way ANOVA with Fisher's LSD post hoc test and the Mann-Whitney U test were used for statistical analyses (alpha=.05). Results. Seventeen (34%) of the FPDs had biological and/or technical complications. Six (12%) FPDs were completely or partially removed during the observation period, 1 framework fractured, and 9 (17.6%) FPDs had ceramic fractures. Fifteen of the 21 fractured FPD units were related to FPDs that were placed in 3 patients with bruxing habits. The CDA rating for marginal integrity was "excellent" for more than 98% of the abutments. No patients reported adverse reactions to the material. Conclusions. Metal-ceramic FPDs made of cobalt-chromium alloy performed acceptably in the questionable prognosis and advanced chronic periodontitis groups.
引用
收藏
页码:6 / 16
页数:11
相关论文
共 61 条
[1]  
ADA Council Sci Affairs, 2003, J AM DENT ASSOC, V134, P476
[2]   The effects of recasting on the cytotoxicity of base metal alloys [J].
Al-Hiyasat, AS ;
Darmani, H .
JOURNAL OF PROSTHETIC DENTISTRY, 2005, 93 (02) :158-163
[3]  
Al-Hiyasat AS, 2003, INT J PROSTHODONT, V16, P8
[4]  
Al-Hiyasat AS, 2002, INT J PROSTHODONT, V15, P473
[5]   COMPARISON OF THE PERFORMANCE ON PROSTHODONTIC CRITERIA OF SEVERAL ALTERNATIVE ALLOYS USED FOR FIXED CROWN AND PARTIAL DENTURE RESTORATIONS - DEPARTMENT-OF-VETERANS-AFFAIRS COOPERATIVE STUDIES PROJECT 147 [J].
ANDERSON, RJ ;
JANES, GR ;
SABELLA, LR ;
MORRIS, HF ;
ZAWADZKI, P ;
PIECH, P ;
BARNES, B ;
JANES, GR ;
STOFFER, W ;
WEIR, D ;
GLASSCOCK, N ;
ASGAR, K ;
HELISEK, A ;
SATHER, M ;
DEYKIN, D ;
HENDERSON, WG ;
ANDERSON, RJ ;
MAIS, R ;
CHRISTINE, B ;
RYGE, G ;
SWARTZ, ML ;
HSI, BP ;
GILLETTE, WB ;
MOFFA, J ;
MOVSESIAN, G ;
STEIN, T ;
BERNAT, N ;
PARK, A ;
PIKULSKI, JF ;
BLANKENSHIP, JR ;
GREGERSON, K ;
LAUCIELLO, F ;
MOZRALL, JF ;
PIETRIE, M ;
CWYNAR, RB ;
STEFFENSMEIR, MA ;
OTOOLE, T ;
SCHLIMMER, SM ;
IRVIN, D ;
CADE, A ;
NAVARRO, A ;
COLLINS, G ;
SATHER, M ;
GOLD, J ;
COLLINS, E ;
DORUS, W ;
EMANUELE, N ;
FELDBUSH, MW ;
FRANKLIN, DL ;
HARVEY, B .
JOURNAL OF PROSTHETIC DENTISTRY, 1993, 69 (01) :1-7
[6]   LASER-WELDED VS SOLDERED NONPRECIOUS ALLOY DENTAL BRIDGES - A COMPARATIVE-STUDY [J].
APOTHEKER, H ;
NISHIMURA, I ;
SEERATTAN, C .
LASERS IN SURGERY AND MEDICINE, 1984, 4 (02) :207-213
[7]   Static immersion and irritation tests of dental metal-ceramic alloys [J].
Ardlin, BI ;
Dahl, JE ;
Tibballs, JE .
EUROPEAN JOURNAL OF ORAL SCIENCES, 2005, 113 (01) :83-89
[8]   Penetration depth into dental casting alloys by Nd:YAG laser [J].
Baba, N ;
Watanabe, I .
JOURNAL OF BIOMEDICAL MATERIALS RESEARCH PART B-APPLIED BIOMATERIALS, 2005, 72B (01) :64-68
[9]  
BARAN GR, 1985, DENT CLIN N AM, V29, P779
[10]   COMPARISON OF FRACTURE STRENGTH OF PORCELAIN-VENEERED-TO-HIGH NOBLE AND BASE-METAL ALLOYS [J].
BARGHI, N ;
MCKEEHANWHITMER, M ;
ARANDA, R .
JOURNAL OF PROSTHETIC DENTISTRY, 1987, 57 (01) :23-26