Investigating droplet separation efficiency in wire-mesh mist eliminators in bubble column

被引:33
|
作者
Al-Dughaither, Abdullah S. [2 ]
Ibrahim, Ahmed A. [1 ]
Al-Masry, Waheed A. [1 ]
机构
[1] King Saud Univ, Dept Chem Engn, Riyadh, Saudi Arabia
[2] SABIC Res & Technol Complex, Riyadh, Saudi Arabia
关键词
Mist eliminator; Wire mesh; Droplet separation; Bubble column; DESIGN; SELECTION;
D O I
10.1016/j.jscs.2010.04.001
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
Effects of design parameters on performance of wire-mesh mist eliminators were experimentally investigated in 15 cm bubble column. The demisters performances were evaluated by droplet collection efficiency as a function of wide ranges of operating and design parameters. These parameters include: droplet size exiting the demister (250-380 mu m), specific surface area (236 868 m(2)/m(3)), void fraction (97-98.3%). wire diameter (0.14 0.28 mm), packing density (130 240 kg/m(3)), and superficial gas velocity (0.109-0.118 m/s. All demisters were 15 cm in diameter with 10 cm pad thickness, made front 316L stainless steel layered type demister pad wires. Experiments were carried out using air water system at ambient temperature and atmospheric pressure. The experimental data on the droplet removal efficiency were obtained using Malvern Laser Droplet Sizer. The removal efficiency was found to increase with the increasing the demister specific surface area, packing density, and superficial gas velocity. In contrast, the removal efficiency was found to increase with decreasing the demister void fraction and wire diameter. The separation efficiency is correlated empirically as a function of the design parameters. A good agreement was obtained between the measured values and the correlation predictions with +/- 5% accuracy. (C) 2010 King Saud University. All rights reserved.
引用
收藏
页码:331 / 339
页数:9
相关论文
共 39 条
  • [1] Investigating pressure drop across wire mesh mist eliminators in bubble column
    Al-Dughaither, Abdullah A.
    Ibrahim, Ahmed A.
    Al-Masry, Waheed A.
    JOURNAL OF SAUDI CHEMICAL SOCIETY, 2011, 15 (01) : 1 - 9
  • [2] Design of complex wire-mesh mist eliminators
    Brunazzi, E
    Paglianti, A
    AICHE JOURNAL, 2000, 46 (06) : 1131 - 1137
  • [3] PROPERLY SPECIFY WIRE-MESH MIST ELIMINATORS
    CAPPS, RW
    CHEMICAL ENGINEERING PROGRESS, 1994, 90 (12) : 49 - 55
  • [4] Design of wire mesh mist eliminators
    Brunazzi, E
    Paglianti, A
    AICHE JOURNAL, 1998, 44 (03) : 505 - 512
  • [5] CALCULATION OF MIST ELIMINATORS MADE OF WIRE MESH
    SEEBACH, E
    CHEMIE INGENIEUR TECHNIK, 1991, 63 (04) : A252 - &
  • [6] Application of a Wire-Mesh Sensor for the Study of Chemical Species Conversion in a Bubble Column
    Kipping, Ragna
    Kryk, Holger
    Schleicher, Eckhard
    Gustke, Matthias
    Hampel, Uwe
    CHEMICAL ENGINEERING & TECHNOLOGY, 2017, 40 (08) : 1425 - 1433
  • [7] Determination of separation efficiency in wire mesh mist eliminator by CFD
    Shen, Shengqiang
    Zhen, Ni
    Mu, Xingsen
    Hedongli Gongcheng/Nuclear Power Engineering, 2014, 35 (05): : 172 - 177
  • [8] Capacity and Sizing of Wire Mesh Mist Eliminators at Critical Fluid Properties
    Flegiel, Felix
    Windmeier, Christoph
    Wiezorek, Michael
    Doess, Alexander
    Schubert, Markus
    Hampel, Uwe
    Schleicher, Eckhard
    CHEMIE INGENIEUR TECHNIK, 2021, 93 (07) : 1166 - 1177
  • [9] A STOCHASTIC-MODEL TO DESCRIBE THE OPERATION OF KNITTED MESH MIST ELIMINATORS, COMPUTATION OF SEPARATION EFFICIENCY
    FEORD, D
    WILCOCK, E
    DAVIES, GA
    CHEMICAL ENGINEERING RESEARCH & DESIGN, 1993, 71 (A3): : 282 - 294
  • [10] Bubble reconstruction method for wire-mesh sensors measurements
    Roman V. Mukin
    Experiments in Fluids, 2016, 57