4D robust optimization including uncertainties in time structures can reduce the interplay effect in proton pencil beam scanning radiation therapy

被引:56
|
作者
Engwall, Erik [1 ]
Fredriksson, Albin [1 ]
Glimelius, Lars [1 ]
机构
[1] RaySearch Labs, Sveavagen 44, SE-11134 Stockholm, Sweden
关键词
4D optimization; interplay effect; motion mitigation; proton therapy; rescanning; robust optimization; CELL LUNG-CANCER; DOSE CALCULATION ACCURACY; RESPIRATORY MOTION; PARTICLE THERAPY; RANGE UNCERTAINTIES; MOVING TARGETS; STAGE-I; RADIOTHERAPY; SENSITIVITY; MITIGATION;
D O I
10.1002/mp.13094
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
PurposeInterplay effects in proton radiotherapy can create large distortions in the dose distribution and severely degrade the plan quality. Standard methods to mitigate these effects include abdominal compression, gating, and rescanning. We propose a new method to include the time structures of the delivery and organ motion in the framework of four-dimensional (4D) robust optimization to generate plans that are robust against interplay effects. MethodsThe method considers multiple scenarios reflecting the uncertainties in the delivery and in the organ motion. In each scenario, the pencil beam scanning spots are distributed to different phases of the breathing cycle according to each individual spot time stamp, and a partial beam dose is calculated for each phase. The partial beam doses are accumulated on a reference phase through deformable image registrations. Minimax optimization is performed to take all scenarios into account simultaneously. For simplicity, the uncertainties in this proof of concept study are limited to variations in the breathing pattern. The method is evaluated for three different nonsmall cell lung cancer patients and compared to plans using conventional 4D robust optimization both with and without rescanning. We assess the ability of the method to mitigate distortions from the interplay effect over multiple evaluation scenarios using 4D dose calculations. This interplay evaluation is performed in an experimentally validated framework, which is independent of the optimization in the plan generation step. ResultsFor the three studied patients, 4D optimization including time structures is efficient, especially for large tumor motions, where rescanning of conventional 4D robustly optimized plans is not sufficient to mitigate the interplay effect. The most efficient approach of the new method is achieved when it is combined with rescanning. For the patient with the largest motion, the mean V95% is 99.2% and mean V107% is 3.65% for the best rescanned 4D plan optimized with time structure. This can be compared to conventional 4D optimized plans with mean V95% of 92.7% and mean V107% of 13.1%. ConclusionsThe current study shows the potential of reducing interplay effects in proton pencil beam scanning radiotherapy by incorporating organ motion and delivery characteristics in a 4D robust optimization.
引用
收藏
页码:4020 / 4029
页数:10
相关论文
共 27 条
  • [21] Interplay effects in proton scanning for lung: a 4D Monte Carlo study assessing the impact of tumor and beam delivery parameters
    Dowdell, S.
    Grassberger, C.
    Sharp, G. C.
    Paganetti, H.
    PHYSICS IN MEDICINE AND BIOLOGY, 2013, 58 (12) : 4137 - 4156
  • [22] Effect of breathing phase number on the 4D robust optimization for pancreatic cancer intensity modulated proton therapy
    Fan, Xiaoying
    Wang, Shuting
    Li, Weijie
    Li, Tengxiang
    Yin, Yong
    Dai, Tianyuan
    BMC CANCER, 2024, 24 (01)
  • [23] Simultaneous dose and dose rate optimization (SDDRO) of the FLASH effect for pencil-beam-scanning proton therapy
    Gao, Hao
    Liu, Jiulong
    Lin, Yuting
    Gan, Gregory N.
    Pratx, Guillem
    Wang, Fen
    Langen, Katja
    Bradley, Jeffrey D.
    Rotondo, Ronny L.
    Li, Harold H.
    Chen, Ronald C.
    MEDICAL PHYSICS, 2022, 49 (03) : 2014 - 2025
  • [24] Comparing the Robustness of Intensity-modulated Proton Therapy and Proton-arc Therapy Against Interplay Effects of 4D Robust-optimised Plans for Lung Stereotactic Body Radiotherapy
    Wei, W. G.
    Yu, H.
    Xiao, Q.
    Li, Z. B.
    Li, J.
    Zhang, X. Y.
    Wu, Y. C.
    Qin, T. L.
    Zeng, X. H.
    Song, Y.
    Li, G. J.
    Bai, S.
    CLINICAL ONCOLOGY, 2025, 39
  • [25] Technical Note: Plan-delivery-time constrained inverse optimization method with minimum-MU-per-energy-layer (MMPEL) for efficient pencil beam scanning proton therapy
    Gao, Hao
    Clasie, Benjamin
    McDonald, Mark
    Langen, Katja M.
    Liu, Tian
    Lin, Yuting
    MEDICAL PHYSICS, 2020, 47 (09) : 3892 - 3897
  • [26] Technical Note: 4D cone-beam CT reconstruction from sparse-view CBCT data for daily motion assessment in pencil beam scanned proton therapy (PBS-PT)
    den Otter, Lydia A.
    Chen, Kuanling
    Janssens, Guillaume
    Meijers, Arturs
    Both, Stefan
    Langendijk, Johannes A.
    Rosen, Lane R.
    Wu, Hsinshun T.
    Knopf, Antje-Christin
    MEDICAL PHYSICS, 2020, 47 (12) : 6381 - 6387
  • [27] Log file-based dose reconstruction and accumulation for 4D adaptive pencil beam scanned proton therapy in a clinical treatment planning system: Implementation and proof-of-concept
    Meijers, A.
    Jakobi, A.
    Stuetzer, K.
    Guterres Marmitt, G.
    Both, S.
    Langendijk, J. A.
    Richter, C.
    Knopf, A.
    MEDICAL PHYSICS, 2019, 46 (03) : 1140 - 1149