4D robust optimization including uncertainties in time structures can reduce the interplay effect in proton pencil beam scanning radiation therapy

被引:56
|
作者
Engwall, Erik [1 ]
Fredriksson, Albin [1 ]
Glimelius, Lars [1 ]
机构
[1] RaySearch Labs, Sveavagen 44, SE-11134 Stockholm, Sweden
关键词
4D optimization; interplay effect; motion mitigation; proton therapy; rescanning; robust optimization; CELL LUNG-CANCER; DOSE CALCULATION ACCURACY; RESPIRATORY MOTION; PARTICLE THERAPY; RANGE UNCERTAINTIES; MOVING TARGETS; STAGE-I; RADIOTHERAPY; SENSITIVITY; MITIGATION;
D O I
10.1002/mp.13094
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
PurposeInterplay effects in proton radiotherapy can create large distortions in the dose distribution and severely degrade the plan quality. Standard methods to mitigate these effects include abdominal compression, gating, and rescanning. We propose a new method to include the time structures of the delivery and organ motion in the framework of four-dimensional (4D) robust optimization to generate plans that are robust against interplay effects. MethodsThe method considers multiple scenarios reflecting the uncertainties in the delivery and in the organ motion. In each scenario, the pencil beam scanning spots are distributed to different phases of the breathing cycle according to each individual spot time stamp, and a partial beam dose is calculated for each phase. The partial beam doses are accumulated on a reference phase through deformable image registrations. Minimax optimization is performed to take all scenarios into account simultaneously. For simplicity, the uncertainties in this proof of concept study are limited to variations in the breathing pattern. The method is evaluated for three different nonsmall cell lung cancer patients and compared to plans using conventional 4D robust optimization both with and without rescanning. We assess the ability of the method to mitigate distortions from the interplay effect over multiple evaluation scenarios using 4D dose calculations. This interplay evaluation is performed in an experimentally validated framework, which is independent of the optimization in the plan generation step. ResultsFor the three studied patients, 4D optimization including time structures is efficient, especially for large tumor motions, where rescanning of conventional 4D robustly optimized plans is not sufficient to mitigate the interplay effect. The most efficient approach of the new method is achieved when it is combined with rescanning. For the patient with the largest motion, the mean V95% is 99.2% and mean V107% is 3.65% for the best rescanned 4D plan optimized with time structure. This can be compared to conventional 4D optimized plans with mean V95% of 92.7% and mean V107% of 13.1%. ConclusionsThe current study shows the potential of reducing interplay effects in proton pencil beam scanning radiotherapy by incorporating organ motion and delivery characteristics in a 4D robust optimization.
引用
收藏
页码:4020 / 4029
页数:10
相关论文
共 27 条
  • [11] 4D dose calculation for pencil beam scanning proton therapy of pancreatic cancer using repeated 4DMRI datasets
    Dolde, Kai
    Naumann, Patrick
    David, Christian
    Gnirs, Regula
    Kachelriess, Marc
    Lomax, Antony John
    Saito, Nami
    Weber, Damien Charles
    Pfaffenberger, Asja
    Zhang, Ye
    PHYSICS IN MEDICINE AND BIOLOGY, 2018, 63 (16)
  • [12] Mitigation of motion effects in pencil-beam scanning-Impact of repainting on 4D robustly optimized proton treatment plans for hepatocellular carcinoma
    Siregar, Hilda
    Baumer, Christian
    Blanck, Oliver
    Chan, Mark
    Engwall, Erik
    Plaude, Sandija
    Spaan, Bernhard
    Timmermann, Beate
    Wulff, Jorg
    ZEITSCHRIFT FUR MEDIZINISCHE PHYSIK, 2022, 32 (01): : 63 - 73
  • [13] A motion model-guided 4D dose reconstruction for pencil beam scanned proton therapy
    Duetschler, A.
    Huang, L.
    Fattori, G.
    Meier, G.
    Bula, C.
    Hrbacek, J.
    Safai, S.
    Weber, D. C.
    Lomax, A. J.
    Zhang, Ye
    PHYSICS IN MEDICINE AND BIOLOGY, 2023, 68 (11)
  • [14] Including anatomical variations in robust optimization for head and neck proton therapy can reduce the need of adaptation
    Cubillos-Mesias, Macarena
    Troost, Esther G. C.
    Lohaus, Fabian
    Agolli, Linda
    Rehm, Maximilian
    Richter, Christian
    Stuetzer, Kristin
    RADIOTHERAPY AND ONCOLOGY, 2019, 131 : 127 - 134
  • [15] A Monte-Carlo-based and GPU-accelerated 4D-dose calculator for a pencil beam scanning proton therapy system
    Pepin, Mark D.
    Tryggestad, Erik
    Tseung, Hok Seum Wan Chan
    Johnson, Jedediah E.
    Herman, Michael G.
    Beltran, Chris
    MEDICAL PHYSICS, 2018, 45 (11) : 5293 - 5304
  • [16] Experimental validation of a 4D dynamic dose calculation model for proton pencil beam scanning without spot time stamp considering free-breathing motion
    Tominaga, Yuki
    Oita, Masataka
    Miyata, Junya
    Kato, Takahiro
    MEDICAL PHYSICS, 2024, 51 (01) : 566 - 578
  • [17] Technical Note: 4D robust optimization in small spot intensity-modulated proton therapy (IMPT) for distal esophageal carcinoma
    Feng, Hongying
    Shan, Jie
    Ashman, Jonathan B.
    Rule, William G.
    Bhangoo, Ronik S.
    Yu, Nathan Y.
    Chiang, Jennifer
    Fatyga, Mirek
    Wong, William W.
    Schild, Steven E.
    Sio, Terence T.
    Liu, Wei
    MEDICAL PHYSICS, 2021, 48 (08) : 4636 - 4647
  • [18] Exploratory Study of 4D versus 3D Robust Optimization in Intensity Modulated Proton Therapy for Lung Cancer
    Liu, Wei
    Schild, Steven E.
    Chang, Joe Y.
    Liao, Zhongxing
    Chang, Yu-Hui
    Wen, Zhifei
    Shen, Jiajian
    Stoker, Joshua B.
    Ding, Xiaoning
    Hu, Yanle
    Sahoo, Narayan
    Herman, Michael G.
    Vargas, Carlos
    Keole, Sameer
    Wong, William
    Bues, Martin
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2016, 95 (01): : 523 - 533
  • [19] 4D strategies for lung tumors treated with hypofractionated scanning proton beam therapy: Dosimetric impact and robustness to interplay effects
    Mastella, Edoardo
    Molinelli, Silvia
    Pella, Andrea
    Vai, Alessandro
    Maestri, Davide
    Vitolo, Viviana
    Baroni, Guido
    Valvo, Francesca
    Ciocca, Mario
    RADIOTHERAPY AND ONCOLOGY, 2020, 146 : 213 - 220
  • [20] A method using 4D dose accumulation to quantify the interplay effect in lung stereotactic body radiation therapy
    Huesa-Berral, Carlos
    Burguete, Javier
    Moreno-Jimenez, Marta
    Diego Azcona, Juan
    PHYSICS IN MEDICINE AND BIOLOGY, 2021, 66 (03)