Temperature dependence of AlGaAs soft X-ray detectors

被引:40
作者
Barnett, A. M. [1 ]
Bassford, D. J. [1 ]
Lees, J. E. [1 ]
Ng, J. S. [2 ]
Tan, C. H. [2 ]
David, J. P. R. [2 ]
机构
[1] Univ Leicester, Dept Phys & Astron, Space Res Ctr, Leicester LE1 7RH, Leics, England
[2] Univ Sheffield, Dept Elect & Elect Engn, Sheffield S1 3JD, S Yorkshire, England
关键词
X-ray; Detector; AlGaAs; Diode; Temperature dependence; Spectroscopy; SPECTROSCOPY;
D O I
10.1016/j.nima.2010.06.089
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
We have fabricated and characterised unpassivated 200 mu m diameter circular mesa Al(0.8)Ga(0.2)As p(+)-i-n(+) diodes as soft X-ray photon counting detectors. The spectroscopic performance, as measured by the FWHM of the 5.9 keV X-ray line from an (55)Fe radioisotope, shows that these detectors can be used for X-ray photon counting spectroscopy with promising energy resolution (0.9-2.5 keV) over a -30 to +90 degrees C temperature range. (C) 2010 Elsevier B.V. All rights reserved.
引用
收藏
页码:453 / 455
页数:3
相关论文
共 6 条
[1]   Criteria of choice of the front-end transistor for low-noise preamplification of detector signals at sub-microsecond shaping times for X- and gamma-ray spectroscopy [J].
Bertuccio, G ;
Pullia, A ;
DeGeronimo, G .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1996, 380 (1-2) :301-307
[2]   Silicon drift detectors for high count rate X-ray spectroscopy at room temperature [J].
Lechner, P ;
Fiorini, C ;
Hartmann, R ;
Kemmer, J ;
Krause, N ;
Leutenegger, P ;
Longoni, A ;
Soltau, H ;
Stötter, D ;
Stötter, R ;
Strüder, L ;
Weber, U .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2001, 458 (1-2) :281-287
[3]   AlGaAs diodes for X-ray spectroscopy [J].
Lees, J. E. ;
Bassford, D. J. ;
Ng, J. S. ;
Tan, C. H. ;
David, J. P. R. .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2008, 594 (02) :202-205
[4]   The ground calibration of X-ray CCD cameras (XIS) with front-illuminated chips onboard Astro-E2 [J].
Nakajima, H ;
Yamaguchi, H ;
Matsumoto, H ;
Tsuru, TG ;
Koyama, K ;
Kissel, S ;
LaMarr, B ;
Bautz, M .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2005, 541 (1-2) :365-371
[5]   Compound semiconductor radiation detectors [J].
Owens, A ;
Peacock, A .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2004, 531 (1-2) :18-37
[6]   NON-GAMMA DEEP LEVELS AND THE CONDUCTION-BAND STRUCTURE OF GA1-XALXAS ALLOYS [J].
SAXENA, AK .
PHYSICA STATUS SOLIDI B-BASIC SOLID STATE PHYSICS, 1981, 105 (02) :777-787