Comparison of quantitative and qualitative PCR assays for cytomegalovirus DNA in plasma

被引:63
|
作者
Caliendo, AM
Schuurman, R
Yen-Lieberman, B
Spector, SA
Andersen, J
Manjiry, R
Crumpacker, C
Lurain, NS
Erice, A
机构
[1] Emory Univ, Dept Pathol & Lab Med, Atlanta, GA 30322 USA
[2] Emory Univ, Dept Med, Div Infect Dis, Atlanta, GA 30322 USA
[3] Univ Utrecht Hosp, Eykman Winkler Inst Clin Microbiol, Dept Virol, Utrecht, Netherlands
[4] Cleveland Clin Fdn, Dept Clin Pathol, Cleveland, OH 44195 USA
[5] Univ Calif San Diego, Dept Pediat Infect Dis, San Diego, CA 92103 USA
[6] Harvard Univ, Sch Publ Hlth, Dept Immunol Microbiol, Stat & Data Anal Ctr, Boston, MA 02115 USA
[7] Harvard Univ, Sch Med, Beth Israel Deaconess Med Ctr, Div Infect Dis, Boston, MA USA
[8] Rush Presbyterian St Lukes Med Ctr, Dept Immunol Microbiol, Chicago, IL 60612 USA
[9] Univ Minnesota, Sch Med, Div Infect Dis, Dept Lab Med & Pathol, Minneapolis, MN USA
[10] Univ Minnesota, Sch Med, Dept Med, Minneapolis, MN USA
关键词
D O I
10.1128/JCM.39.4.1334-1338.2001
中图分类号
Q93 [微生物学];
学科分类号
071005 ; 100705 ;
摘要
We analyzed the performance characteristics of the qualitative AMPLICOR CMV Test (Roche Molecular Systems, Pleasanton, Calif,) and quantitative COBAS AMPLICOR CMV MONITOR Test (Roche Molecular Systems) assays and compared the performance of the AMPLICOR quantitative assay with an in-house-developed cytomegalovirus (CMV) DNA PCR assay. The quantitative AMPLICOR assay was found to be more sensitive than the qualitative AMPLICOR assay. The quantitative AMPLICOR assay has a lower limit of sensitivity of 400 CMV DNA copies/ml of plasma and is linear to 50,000 CMV DNA copies/ml of plasma, Compared to the in-house PCR assay, the AMPLICOR quantitative assay gave lower viral load values at all concentrations tested, but the difference between the two assays was not consistent across the entire dynamic range of the AMPLICOR quantitative assay, At the lower end of the assay, the viral load values obtained with the in-house PCR assay were three- to fivefold (0.5 to 0.7 log units) higher than those measured with the AMPLICOR assay. At higher input concentrations, the differences between the two assays approached 10-fold, This direct comparison of the in-house assay and the quantitative AMPLICOR assay provides the ability to compare previously published in-house data with an assay widely available for future research and clinical monitoring of patients with CMV infections.
引用
收藏
页码:1334 / 1338
页数:5
相关论文
共 50 条
  • [1] Comparison of two quantitative detection assays of cytomegalovirus DNA
    Madsen, Tina Vasehus
    Lilliedal, Jeannette Kaslund
    Nielsen, Xiaohui Chen
    JOURNAL OF CLINICAL VIROLOGY, 2016, 82 : S41 - S42
  • [2] Qualitative and quantitative detection of cytomegalovirus DNA in sera by PCR as a clinical marker
    Naitou, H
    Mimaya, J
    Horikoshi, Y
    Takashima, Y
    Amano, K
    Morita, T
    BIOLOGICAL & PHARMACEUTICAL BULLETIN, 1998, 21 (12) : 1371 - 1375
  • [3] Comparison of Six Real-Time PCR Assays for Qualitative Detection of Cytomegalovirus in Clinical Specimens
    Binnicker, M. J.
    Espy, M. E.
    JOURNAL OF CLINICAL MICROBIOLOGY, 2013, 51 (11) : 3749 - 3752
  • [4] Optimization of quantitative detection of cytomegalovirus DNA in plasma by real-time PCR
    Boeckh, M
    Huang, M
    Ferrenberg, J
    Stevens-Ayers, T
    Stensland, L
    Nichols, WG
    Corey, L
    JOURNAL OF CLINICAL MICROBIOLOGY, 2004, 42 (03) : 1142 - 1148
  • [5] Qualitative PCR Safety Assays Show Better Sensitivity than Quantitative PCR Assays
    Jones, Scott
    Butler, Izekiel
    Beddard, Rachel
    TRANSFUSION, 2021, 61 : 104A - 104A
  • [6] Monitoring human cytomegalovirus infection with nested PCR: comparison of positive rates in plasma and leukocytes and with quantitative PCR
    Shu Zhang
    Yi-Hua Zhou
    Lei Li
    Yali Hu
    Virology Journal, 7
  • [7] Monitoring human cytomegalovirus infection with nested PCR: comparison of positive rates in plasma and leukocytes and with quantitative PCR
    Zhang, Shu
    Zhou, Yi-Hua
    Li, Lei
    Hu, Yali
    VIROLOGY JOURNAL, 2010, 7
  • [8] Quantitative PCR Assays of Cytomegalovirus and Epstein-Barr Virus in Hemophagocytic Lymphohistiocytosis
    Kana Okazaki
    Ken-Ichi Imadome
    Hiro Nakao
    Isao Miyairi
    Akira Ishiguro
    The Indian Journal of Pediatrics, 2018, 85 : 593 - 594
  • [9] Quantitative PCR Assays of Cytomegalovirus and Epstein-Barr Virus in Hemophagocytic Lymphohistiocytosis
    Okazaki, Kana
    Imadome, Ken-Ichi
    Nakao, Hiro
    Miyairi, Isao
    Ishiguro, Akira
    INDIAN JOURNAL OF PEDIATRICS, 2018, 85 (07): : 593 - 594
  • [10] Comparison of quantitative and qualitative anti-dsDNA assays
    Selvaratnam, Rajeevan
    Srivastava, Pooja
    Tacker, Danyel H.
    Thebo, Jennifer
    Wheeler, Sarah E.
    LABORATORY MEDICINE, 2024, 55 (06) : 732 - 738