Comparison of quantitative and qualitative PCR assays for cytomegalovirus DNA in plasma
被引:63
作者:
Caliendo, AM
Schuurman, R
Yen-Lieberman, B
Spector, SA
Andersen, J
Manjiry, R
Crumpacker, C
Lurain, NS
Erice, A
机构:
[1] Emory Univ, Dept Pathol & Lab Med, Atlanta, GA 30322 USA
[2] Emory Univ, Dept Med, Div Infect Dis, Atlanta, GA 30322 USA
[3] Univ Utrecht Hosp, Eykman Winkler Inst Clin Microbiol, Dept Virol, Utrecht, Netherlands
[4] Cleveland Clin Fdn, Dept Clin Pathol, Cleveland, OH 44195 USA
[5] Univ Calif San Diego, Dept Pediat Infect Dis, San Diego, CA 92103 USA
[6] Harvard Univ, Sch Publ Hlth, Dept Immunol Microbiol, Stat & Data Anal Ctr, Boston, MA 02115 USA
[7] Harvard Univ, Sch Med, Beth Israel Deaconess Med Ctr, Div Infect Dis, Boston, MA USA
[8] Rush Presbyterian St Lukes Med Ctr, Dept Immunol Microbiol, Chicago, IL 60612 USA
[9] Univ Minnesota, Sch Med, Div Infect Dis, Dept Lab Med & Pathol, Minneapolis, MN USA
[10] Univ Minnesota, Sch Med, Dept Med, Minneapolis, MN USA
关键词:
D O I:
10.1128/JCM.39.4.1334-1338.2001
中图分类号:
Q93 [微生物学];
学科分类号:
071005 ;
100705 ;
摘要:
We analyzed the performance characteristics of the qualitative AMPLICOR CMV Test (Roche Molecular Systems, Pleasanton, Calif,) and quantitative COBAS AMPLICOR CMV MONITOR Test (Roche Molecular Systems) assays and compared the performance of the AMPLICOR quantitative assay with an in-house-developed cytomegalovirus (CMV) DNA PCR assay. The quantitative AMPLICOR assay was found to be more sensitive than the qualitative AMPLICOR assay. The quantitative AMPLICOR assay has a lower limit of sensitivity of 400 CMV DNA copies/ml of plasma and is linear to 50,000 CMV DNA copies/ml of plasma, Compared to the in-house PCR assay, the AMPLICOR quantitative assay gave lower viral load values at all concentrations tested, but the difference between the two assays was not consistent across the entire dynamic range of the AMPLICOR quantitative assay, At the lower end of the assay, the viral load values obtained with the in-house PCR assay were three- to fivefold (0.5 to 0.7 log units) higher than those measured with the AMPLICOR assay. At higher input concentrations, the differences between the two assays approached 10-fold, This direct comparison of the in-house assay and the quantitative AMPLICOR assay provides the ability to compare previously published in-house data with an assay widely available for future research and clinical monitoring of patients with CMV infections.