A simple benzildihydrazone derived colorimetric and fluorescent 'on-off-on' sensor for sequential detection of copper(II) and cyanide ions in aqueous solution

被引:103
作者
Chandra, Rukmani [1 ]
Ghorai, Anupam [1 ]
Patra, Goutam K. [1 ]
机构
[1] Guru Ghasidas Vishwavidyalaya, Dept Chem, Bilaspur, India
来源
SENSORS AND ACTUATORS B-CHEMICAL | 2018年 / 255卷
关键词
Fluorescent chemosensor; Colorimetric sensor; Sequential detection; Cu2+ ion; CN-; ion; SCHIFF BASE SENSOR; RAPID DETECTION; CU2+; CHEMOSENSOR; MERCURY; WATER; EXTRACTION; PROBE; GOLD; AL3+;
D O I
10.1016/j.snb.2017.08.067
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Herein, we have developed a simple, environment friendly fluorescent turn-off and colorimetric sensor for the rapid detection of Cu7' ions in aqueous solution by using organic Schiff base ligand benzildihydrazoneN,IT-bis(2-hydroxy-4-diethylamino-1 -formy /benzene)(L). Binding interaction between Land various metal ions was established by UV-vis and fluorescent measurements showing favourable coordination towards Cu7+ and almost no interference with the other metal ions, i.e., Na+, Ba7+, Fe3+, Co7+, Ni7+, Zn7+, Cd7+, Ca7+, He+, Pb7+,Cr3+, Ag* and Al3+. L exhibited binding-induced colour change from yellow to light red. The obtained L-Cu7+ complex could be used as a new cascade sensor for detecting cyanide anion (CN-). The corresponding detection limits were found to be 7.3 x 10(-10) M for Cu7+ (lowest ever known in the family of fluorescent colorimetric Schiff base chemo-sensor) and 1.5 x 10(-7) M for CN-1. To further assess the analytical performance of this sensing system, the concentrations of Cu7+ and CN-1 ions were determined in real water samples and simulated urine sample. (C) 2017 Elsevier B.V. All rights reserved.
引用
收藏
页码:701 / 711
页数:11
相关论文
共 71 条
[31]   Copper(II) binding to α-synuclein, the Parkinson's protein [J].
Lee, Jennifer C. ;
Gray, Harry B. ;
Winkler, Jay R. .
JOURNAL OF THE AMERICAN CHEMICAL SOCIETY, 2008, 130 (22) :6898-+
[32]   Fluorescent chemodosimeter for selective detection of cyanide in water [J].
Lee, Kyung-Sik ;
Kim, Hae. -Jo ;
Kim, Gun-Hee ;
Shin, Injae ;
Hong, Jong-In .
ORGANIC LETTERS, 2008, 10 (01) :49-51
[33]  
Li H., 2011, CHEM COMMUN, V47, P9378
[34]   A label-free conjugated polymer-based fluorescence assay for the determination of adenosine triphosphate and alkaline phosphatase [J].
Li, Yanan ;
Li, Yan ;
Wang, Xinyan ;
Su, Xingguang .
NEW JOURNAL OF CHEMISTRY, 2014, 38 (09) :4574-4579
[35]   Rationally introduce multi-competitive binding interactions in supramolecular gels: a simple and efficient approach to develop multi-analyte sensor array [J].
Lin, Qi ;
Lu, Tao-Tao ;
Zhu, Xin ;
Wei, Tai-Bao ;
Li, Hui ;
Zhang, You-Ming .
CHEMICAL SCIENCE, 2016, 7 (08) :5341-5346
[36]   Copper Complex Based Chemosensor which Could Colorimetrically Detect CN- in Water with Specific Selectivity and High Sensitivity [J].
Lin Qi ;
Zhu Xin ;
Chen Pei ;
Fu Yongpeng ;
Zhang Youming ;
Wei Taibao .
ACTA CHIMICA SINICA, 2013, 71 (11) :1516-1520
[37]   Reaction-Based Ratiometric Chemosensor for Instant Detection of Cyanide in Water with High Selectivity and Sensitivity [J].
Lin, Qi ;
Liu, Xin ;
Wei, Tai-Bao ;
Zhang, You-Ming .
CHEMISTRY-AN ASIAN JOURNAL, 2013, 8 (12) :3015-3021
[38]   Colorimetric detection of cyanide with phenyl thiourea derivatives [J].
Lin, Yi-Shan ;
Zheng, Jia-Xing ;
Tsui, Yao-Kang ;
Yen, Yao-Pin .
SPECTROCHIMICA ACTA PART A-MOLECULAR AND BIOMOLECULAR SPECTROSCOPY, 2011, 79 (05) :1552-1558
[39]   A novel rhodamine-based colorimetric and fluorescent sensor for the dual-channel detection of Cu2+ and Fe3+ in aqueous solutions [J].
Liu, Aifeng ;
Yang, Liang ;
Zhang, Zhenyu ;
Zhang, Zhilan ;
Xu, Dongmei .
DYES AND PIGMENTS, 2013, 99 (02) :472-479
[40]   CHROMOIONOPHORES AND FLUOROIONOPHORES - A NEW CLASS OF DYE REAGENTS [J].
LOHR, HG ;
VOGTLE, F .
ACCOUNTS OF CHEMICAL RESEARCH, 1985, 18 (03) :65-72