Energy saving and thermal comfort performance of air conditioners incorporating distributed environmental sensing by wireless sensor network

被引:1
作者
Chiu, Min-sheng [1 ]
Kristantama, Johan [2 ]
Tzeng, Chun-Ta [1 ]
Lai, Chi-Ming [2 ]
机构
[1] Natl Cheng Kung Univ, Dept Architecture, Tainan 701, Taiwan
[2] Natl Cheng Kung Univ, Dept Civil Engn, 1 Univ Rd, Tainan 701, Taiwan
关键词
Energy; thermal comfort; air conditioner; distributed environmental sensing; wireless sensor network; COMPRESSOR; SIMULATION; OPERATION;
D O I
10.1177/0954408914542275
中图分类号
TH [机械、仪表工业];
学科分类号
0802 ;
摘要
Appropriate spatial temperature sensing is recognized as one of the main challenges for thermostats used in air conditioners. In this study, a motivation is emerged to change this return-air-sensing by integrating the concept of distributed environment sensing toward the air-conditioning system (DES-A/C). An improved A/C system was established incorporating distributed environmental sensing by wireless sensor networks. Experimental research with two different treatments, single-point and multi-point user-neighborhood sensing, has been conducted to demonstrate the feasibility of this concept. It has been revealed that DES-A/C could save 43% energy compared to conventional A/C. In addition, DES-A/C could maintain the predicted mean vote (PMV) index in satisfaction range (-1<PMV<+1) and predicted percentage of dissatisfied index no more than 27.5%.
引用
收藏
页码:158 / 167
页数:10
相关论文
共 9 条
[1]  
Albert S., 2009, CIBSE TECHN SEM
[2]  
[Anonymous], 7730 ISO
[3]   Determination of the compressor optimal working conditions [J].
Aprea, C. ;
Mastrullo, R. ;
Renno, C. .
APPLIED THERMAL ENGINEERING, 2009, 29 (10) :1991-1997
[4]   Simulation-based control of building systems operation [J].
Mahdavi, A .
BUILDING AND ENVIRONMENT, 2001, 36 (06) :789-796
[5]  
Nathan KO, 2007, THESIS U CALIFORNIA
[6]   Kilavi platform for wireless building automation [J].
Oksa, P. ;
Soini, M. ;
Sydanheimo, L. ;
Kivikoski, M. .
ENERGY AND BUILDINGS, 2008, 40 (09) :1721-1730
[7]   Object lessons learned from a distributed system for remote building monitoring and operation [J].
Olken, F ;
Jacobsen, HA ;
McParland, C ;
Piette, MA ;
Anderson, MF .
ACM SIGPLAN NOTICES, 1998, 33 (10) :284-295
[8]   A computer simulation of a rotary compressor for household refrigerators [J].
Ooi, KT ;
Wong, TN .
APPLIED THERMAL ENGINEERING, 1997, 17 (01) :65-78
[9]   A distributed sensor network for measurement of human thermal comfort feelings [J].
Tse, Wai Leung ;
Chan, Wai Lok .
SENSORS AND ACTUATORS A-PHYSICAL, 2008, 144 (02) :394-402