Uncertainty of relative sensitivity factors in glow discharge mass spectrometry

被引:11
作者
Meija, Juris [1 ]
Methven, Brad [1 ]
Sturgeon, Ralph E. [1 ]
机构
[1] Natl Res Council Canada, Measurement Sci & Stand, 1200 Montreal Rd, Ottawa, ON K1A 0R6, Canada
关键词
glow discharge mass spectrometry; calibration model; relative sensitivity factors; traceability; uncertainty evaluation; least squares adjustment; PHYSICAL CONSTANTS; CALIBRATION; PURITY; VALUES;
D O I
10.1088/1681-7575/aa83d6
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
The concept of the relative sensitivity factors required for the correction of the measured ion beam ratios in pin-cell glow discharge mass spectrometry is examined in detail. We propose a data-driven model for predicting the relative response factors, which relies on a non-linear least squares adjustment and analyte/matrix interchangeability phenomena. The model provides a self-consistent set of response factors for any analyte/matrix combination of any element that appears as either an analyte or matrix in at least one known response factor.
引用
收藏
页码:796 / 804
页数:9
相关论文
共 50 条
  • [21] Determination of relative sensitivity factors of elements in high purity copper by doping-melting and doping-pressed methods using glow discharge mass spectrometry
    Zhang, Jianying
    Zhou, Tao
    Tang, Yichuan
    Cui, Yanjie
    Li, Jinying
    JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2016, 31 (11) : 2182 - 2191
  • [22] Evaluation of Relative Sensitivity Factors for Elemental Analysis of Aluminum and Magnesium Using Glow Discharge Mass Spectrometry with a Fast-Flow Grimm-type Ion Source
    Yamada, Kentaro
    Uemoto, Michihisa
    ANALYTICAL SCIENCES, 2018, 34 (06) : 743 - 746
  • [23] Glow Discharge Mass Spectrometry for Cobalt Alloys Analysis
    Itoh, Shinji
    Yamada, Katsura
    Kobayashi, Takeshi
    BUNSEKI KAGAKU, 2009, 58 (01) : 27 - 31
  • [24] Determination of oxygen in magnesium by glow discharge mass spectrometry
    Kikuta, Emi
    Asano, Hiloshi
    Kikuchi, Tadashi
    TETSU TO HAGANE-JOURNAL OF THE IRON AND STEEL INSTITUTE OF JAPAN, 2007, 93 (02): : 128 - 131
  • [25] Determination of tramp elements in iron and steel by glow discharge mass spectrometry
    Itoh, S
    Yamaguchi, H
    Hamano, I
    Hobo, T
    Kobayashi, T
    TETSU TO HAGANE-JOURNAL OF THE IRON AND STEEL INSTITUTE OF JAPAN, 2003, 89 (09): : 962 - 966
  • [26] ENHANCEMENT OF SENSITIVITY BY AR/H-2 GAS MIXTURE IN GLOW DISCHARGE MASS SPECTROMETRY
    Saito, Morimasa
    ANALYTICAL SCIENCES, 1991, 7 : 541 - 543
  • [27] Rapid and quantitative analysis of impurities in silicon powders by glow discharge mass spectrometry
    Jianying Zhang
    Tao Zhou
    Yichuan Tang
    Yanjie Cui
    Dan Song
    Analytical and Bioanalytical Chemistry, 2018, 410 : 7195 - 7201
  • [28] Quantification of Trace Impurities in Graphite by Glow Discharge Mass Spectrometry
    Wang Zi-ren
    Wang Chang-hua
    Hu Fang-fei
    Li Ji-dong
    SPECTROSCOPY AND SPECTRAL ANALYSIS, 2019, 39 (04) : 1256 - 1261
  • [29] ANALYSIS OF SOILS BY GLOW-DISCHARGE MASS-SPECTROMETRY
    DUCKWORTH, DC
    BARSHICK, CM
    SMITH, DH
    JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 1993, 8 (06) : 875 - 879
  • [30] Multielemental characterisation of cobalt by glow discharge quadrupole mass spectrometry
    Raparthi, S
    Arunachalam, J
    Das, N
    Murthy, AMS
    TALANTA, 2005, 65 (05) : 1270 - 1278