Uncertainty of relative sensitivity factors in glow discharge mass spectrometry

被引:11
作者
Meija, Juris [1 ]
Methven, Brad [1 ]
Sturgeon, Ralph E. [1 ]
机构
[1] Natl Res Council Canada, Measurement Sci & Stand, 1200 Montreal Rd, Ottawa, ON K1A 0R6, Canada
关键词
glow discharge mass spectrometry; calibration model; relative sensitivity factors; traceability; uncertainty evaluation; least squares adjustment; PHYSICAL CONSTANTS; CALIBRATION; PURITY; VALUES;
D O I
10.1088/1681-7575/aa83d6
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
The concept of the relative sensitivity factors required for the correction of the measured ion beam ratios in pin-cell glow discharge mass spectrometry is examined in detail. We propose a data-driven model for predicting the relative response factors, which relies on a non-linear least squares adjustment and analyte/matrix interchangeability phenomena. The model provides a self-consistent set of response factors for any analyte/matrix combination of any element that appears as either an analyte or matrix in at least one known response factor.
引用
收藏
页码:796 / 804
页数:9
相关论文
共 50 条
  • [1] Relative sensitivity factors for analyzing carbon and nitrogen in steels by glow discharge mass spectrometry
    Itoh, S
    Yamaguchi, H
    Yoshioka, T
    Kimura, T
    Kobayashi, T
    MATERIALS TRANSACTIONS JIM, 2000, 41 (04): : 516 - 521
  • [2] Relative sensitivity factors in glow discharge mass spectrometry: The role of charge transfer ionization
    Bogaerts, A
    Gijbels, R
    JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 1996, 11 (09) : 841 - 847
  • [3] Relative sensitivity factors for the analysis of aluminum in iron and titanium matrices by glow discharge mass spectrometry
    Itoh, S
    Yamaguchi, H
    Sakuma, N
    Hobo, T
    Kobayashi, T
    BUNSEKI KAGAKU, 2003, 52 (08) : 605 - 610
  • [4] Calculation of rate constants for asymmetric charge transfer, and their effect on relative sensitivity factors in glow discharge mass spectrometry
    Bogaerts, Annemie
    Temelkov, Krassimir A.
    Vuchkov, Nikolay K.
    Gijbels, Renaat
    SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 2007, 62 (04) : 325 - 336
  • [5] RELATIVE SENSITIVITY FACTORS IN GLOW-DISCHARGE MASS-SPECTROMETRIC ANALYSIS OF STEELS
    ITOH, S
    HIROSE, F
    HASEGAWA, R
    JOURNAL OF THE JAPAN INSTITUTE OF METALS, 1994, 58 (05) : 526 - 531
  • [6] Determination of Relative Sensitivity Factors of Impurities in Poly-Silicon by Derect Current Glow Discharge Mass Spectrometry
    Liu Jie
    Qian Rong
    Siqin Bilige
    Zhuo Shang-Jun
    He Pin-Gang
    CHINESE JOURNAL OF ANALYTICAL CHEMISTRY, 2012, 40 (01) : 66 - 71
  • [7] Determination and study of correlations of relative sensitivity factors in metal and metal oxide samples by glow discharge mass spectrometry
    Liu, Anqi
    Zeng, Wang
    Zhu, Zhenli
    Zhuo, Shangjun
    Liu, Xuechao
    He, Chenggen
    Fang, Jinghong
    He, Huan
    Qian, Rong
    MICROCHEMICAL JOURNAL, 2024, 205
  • [8] Relative sensitivity factor for various matrices using argon/glow discharge mass spectrometry
    Itoh, Shinji
    Oguro, Nobutaka
    Kobayashi, Takeshi
    TETSU TO HAGANE-JOURNAL OF THE IRON AND STEEL INSTITUTE OF JAPAN, 2008, 94 (07): : 265 - 269
  • [9] Relative sensitivity factor of nitrogen in steel by Helium/Glow discharge-mass spectrometry
    Itoh, Shinji
    Oguro, Nobutaka
    Kobayashi, Takeshi
    TETSU TO HAGANE-JOURNAL OF THE IRON AND STEEL INSTITUTE OF JAPAN, 2007, 93 (04): : 336 - 340
  • [10] The direct quantification by glow discharge mass spectrometry with the universal relative sensitivity factors without matrix-matched standards
    Wei, Xinjian
    Qin, Zhen
    Xiong, Penghui
    Wang, Liping
    Zhang, Hailu
    Deng, Dachao
    Liao, Junsheng
    SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 2019, 154 : 43 - 49