Automated estimation of initial and terminal contact timing using accelerometers; Development and validation in transtibial amputees and controls

被引:105
作者
Selles, RW [1 ]
Formanoy, MAG
Bussmann, JBJ
Janssens, PJ
Stam, HJ
机构
[1] Erasmus Med Ctr, Dept Rehabil Med, NL-3000 CA Rotterdam, Netherlands
[2] Med Ctr Rijnmond Zuid, Dept Rehabil Med, NL-3007 AC Rotterdam, Netherlands
关键词
amputation; gait; rehabilitation; signal processing;
D O I
10.1109/TNSRE.2004.843176
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
The aim of this study was to develop and validate an automated accelerometry-based system for estimating, initial contact (IC) and terminal contact (TC) timing information from walking patterns of healthy control subjects and transtibial amputees that can be used in daily,life with minimal interference of researchers. Subjects were instrumented with two uniaxial accelerometers just below the knee while synchronized ground reaction force (GRIT) recordings were used as reference measurements. An automated multiphase algorithm was developed to estimate the time of IC and TC in the acceleration signals of five healthy subjects and two transtibial amputees walking at different walking speeds. The accuracy of the detection algorithm in ten control subjects and eight transtibial amputees indicated mean errors ranging between 0.013 and 0.034 s for the TC and IC timing, with 95% confidence interval of the individual step errors ranging between -0.062. and 0.115 s. Correlation coefficients between the estimated stance phase duration and GRF data were 0.98 and 0.97 for controls and amputees, respectively. We concluded that IC and TC can be accurately and easily measured using this system in both healthy subjects and transtibial amputees walking at different walking speeds. The system can be used in clinical situations or gait labs as well as during daily life.
引用
收藏
页码:81 / 88
页数:8
相关论文
共 19 条
[1]   Temporal feature estimation during walking using miniature accelerometers: an analysis of gait improvement after hip arthroplasty [J].
Aminian, K ;
Rezakhanlou, K ;
De Andres, E ;
Fritsch, C ;
Leyvraz, PF ;
Robert, P .
MEDICAL & BIOLOGICAL ENGINEERING & COMPUTING, 1999, 37 (06) :686-691
[2]   Contributions of proximal and distal moments to axial tibial rotation during walking and running [J].
Bellchamber, TL ;
van den Bogert, AJ .
JOURNAL OF BIOMECHANICS, 2000, 33 (11) :1397-1403
[3]   Daily physical activity and heart rate response in people with a unilateral transtibial amputation for vascular disease [J].
Bussmann, JB ;
Grootscholten, EA ;
Stam, HJ .
ARCHIVES OF PHYSICAL MEDICINE AND REHABILITATION, 2004, 85 (02) :240-244
[4]   Measuring daily behavior using ambulatory accelerometry: The activity monitor [J].
Bussmann, JBJ ;
Martens, WLJ ;
Tulen, JHM ;
Schasfoort, FC ;
van den Berg-Emons, HJG ;
Stam, HJ .
BEHAVIOR RESEARCH METHODS INSTRUMENTS & COMPUTERS, 2001, 33 (03) :349-356
[5]   Analysis and decomposition of signals obtained by thigh-fixed uni-axial accelerometry during normal walking [J].
Bussmann J.B.J. ;
Damen L. ;
Stam H.J. .
Medical and Biological Engineering and Computing, 2000, 38 (6) :632-638
[6]  
Coleman KL, 1999, J REHABIL RES DEV, V36, P8
[7]   Gait analysis in rehabilitation medicine - A brief report [J].
Cooper, RA ;
Quatrano, LA ;
Stanhope, SJ ;
Cavanagh, PR ;
Miller, F ;
Kerrigan, DC ;
Esquenazi, A ;
Harris, GF ;
Winters, LM .
AMERICAN JOURNAL OF PHYSICAL MEDICINE & REHABILITATION, 1999, 78 (03) :278-280
[8]  
Czerniecki J.M., 1995, GAIT POSTURE, V4, P258
[9]   INTERRATER RELIABILITY OF VIDEOTAPED OBSERVATIONAL GAIT-ANALYSIS ASSESSMENTS [J].
EASTLACK, ME ;
ARVIDSON, J ;
SNYDERMACKLER, L ;
DANOFF, JV ;
MCGARVEY, CL .
PHYSICAL THERAPY, 1991, 71 (06) :465-472
[10]  
Evans AB, 2002, SCI-FICTION STUD, V29, P1