Multiresidue analysis of nine anticoagulant rodenticides in serum

被引:35
作者
Palazoglu, MG [1 ]
Tor, ER [1 ]
Holstege, DM [1 ]
Galey, FD [1 ]
机构
[1] Univ Calif Davis, Toxicol Lab, Calif Vet Diagnost Lab Syst, Davis, CA 95616 USA
关键词
anticoagulants; rodenticides; HPLC; DAD; analysis; fluorescence detector;
D O I
10.1021/jf9803886
中图分类号
S [农业科学];
学科分类号
09 ;
摘要
A rapid procedure was developed for the determination of nine anticoagulant rodenticides in animal serum by high-performance liquid chromatography (HPLC) with a fluorescence and photodiode array detector (DAD). The anticoagulants coumafuryl, pindone, warfarin, coumachlor, diphacinone, chlorphacinone, bromadialone, brodifacoum, and difethialone were extracted and quantitated simultaneously with this method. Anticoagulants were extracted at pH 5.5 with 5% (v/v) ethanol in ethyl acetate and 1% (w/v) trichloroacetic acid. Sample extracts were subjected to a cleanup on a Florisil solid-phase extraction (SPE) column. Separation was performed with a reversed phase amine-deactivated C-18 column with a gradient of phosphate buffer, acetonitrile, and methanal. The eluent was monitored with the fluorescence detection at an excitation wavelength of 310 nm and an emission wavelength of 390 nm, and the photodiode array detection was set to 325 nm. Recoveries from spiked serum samples at ranges of 0.004-1 ppm were between 73 and 105%. The precision (CV) data range was between 1.6 and 15.6%. Detection limits were between 0.005 and 0.002 ppm for the fluorescence detection and between 0.020 and 0.050 ppm for the photodiode array detection at 325 nm.
引用
收藏
页码:4260 / 4266
页数:7
相关论文
共 23 条
[1]  
ADDISON JB, 1982, J ASSOC OFF ANA CHEM, V65, P1299
[2]   ANTICOAGULANT POISONING IN ANIMALS - A SIMPLE NEW HIGH-PERFORMANCE THIN-LAYER CHROMATOGRAPHIC (HPTLC) METHOD FOR THE SIMULTANEOUS DETERMINATION OF 8 ANTICOAGULANT RODENTICIDES IN LIVER SAMPLES [J].
BERNY, PJ ;
BURONFOSSE, T ;
LORGUE, G .
JOURNAL OF ANALYTICAL TOXICOLOGY, 1995, 19 (07) :576-580
[3]   DETERMINATION OF CHLOROPHACINONE AND DIPHENADIONE RESIDUES IN BIOLOGICAL-MATERIALS [J].
BULLARD, RW ;
HOLGUIN, G ;
PETERSON, JE .
JOURNAL OF AGRICULTURAL AND FOOD CHEMISTRY, 1975, 23 (01) :72-74
[4]   SIMULTANEOUS DETERMINATION OF 8 ANTICOAGULANT RODENTICIDES IN BLOOD-SERUM AND LIVER [J].
CHALERMCHAIKIT, T ;
FELICE, LJ ;
MURPHY, MJ .
JOURNAL OF ANALYTICAL TOXICOLOGY, 1993, 17 (01) :56-61
[5]   SEPARATION OF SOME THERAPEUTICALLY IMPORTANT COUMARINS AND RELATED COMPOUNDS BY THIN-LAYER CHROMATOGRAPHY [J].
DAENENS, P ;
VANBOVEN, M .
JOURNAL OF CHROMATOGRAPHY, 1971, 57 (02) :319-&
[6]   THERMOSPRAY AND PARTICLE BEAM LIQUID-CHROMATOGRAPHIC MASS-SPECTROMETRIC ANALYSIS OF COUMARIN ANTICOAGULANTS [J].
DEVRIES, JX ;
KYMBER, KA .
JOURNAL OF CHROMATOGRAPHY-BIOMEDICAL APPLICATIONS, 1991, 562 (1-2) :31-38
[7]   DETERMINATION OF NANOGRAM LEVELS OF THE ANTI-COAGULANT ACENOCOUMARIN IN SERUM BY HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY [J].
DEWOLFF, FA ;
TETTEROOTEMPELMAN, CAM ;
EDELBROEK, PM .
JOURNAL OF ANALYTICAL TOXICOLOGY, 1980, 4 (03) :156-159
[8]   Reversed-phase HPLC determination of eight anticoagulant rodenticides in animal liver [J].
Fauconnet, V ;
Pouliquen, H ;
Pinault, L .
JOURNAL OF ANALYTICAL TOXICOLOGY, 1997, 21 (07) :548-553
[9]   MULTICOMPONENT DETERMINATION OF 4-HYDROXYCOUMARIN ANTICOAGULANT RODENTICIDES IN BLOOD-SERUM BY LIQUID-CHROMATOGRAPHY WITH FLUORESCENCE DETECTION [J].
FELICE, LJ ;
CHALERMCHAIKIT, T ;
MURPHY, MJ .
JOURNAL OF ANALYTICAL TOXICOLOGY, 1991, 15 (03) :126-129
[10]   IMPROVED HPLC METHOD FOR DETERMINING BRODIFACOUM IN ANIMAL-TISSUES [J].
HOOGENBOOM, JJL ;
RAMMELL, CG .
BULLETIN OF ENVIRONMENTAL CONTAMINATION AND TOXICOLOGY, 1983, 31 (02) :239-243