Can electromagnetic-navigated maxillary positioning replace occlusional splints in orthognathic surgery? A clinical pilot study

被引:20
作者
Berger, Moritz [1 ]
Nova, Igor [2 ]
Kallus, Sebastian
Ristow, Oliver [1 ]
Freudlsperger, Christian [1 ]
Eisenmann, Urs [2 ]
Dickhaus, Hartmut [2 ]
Engel, Michael [1 ]
Hoffmann, Juergen [1 ]
Seeberger, Robin [1 ]
机构
[1] Univ Hosp Heidelberg, Dept Oral & Maxillofacial Surg, Neuenheimer Feld 400, D-69120 Heidelberg, Germany
[2] Univ Hosp Heidelberg, Dept Med Biometry & Informat, Heidelberg, Germany
关键词
Splintless; Waferless; Orthognathic surgery; Guided surgery; Electromagnetic navigation; Computer assisted surgery; BEAM COMPUTED-TOMOGRAPHY; MAXILLOFACIAL SURGERY; SURGICAL NAVIGATION; TRACKING; ACCURACY; SYSTEM; RECONSTRUCTIONS;
D O I
10.1016/j.jcms.2017.08.005
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Introduction: Because of the inaccuracy of intermaxillary splints in orthognathic surgery, intraoperative guidance via a real time navigation system might represent a suitable method for enhancing the precision of maxillary positioning. Therefore, in this clinical trial, maxillary repositioning after Le Fort I osteotomy was guided splintless by an electromagnetic navigation system. Materials and methods: Conservatively planned maxillary reposition in each of 5 patients was transferred to a novel software module of the electromagnetic navigation system. Intraoperatively, after Le Fort I osteotomy, the software guided the maxilla to the targeted position. Accuracy was evaluated by pre- and postoperative cone beam computer tomography imaging (the vectorial distance of the incisal marker points was measured in three dimensions) and compared with that of a splint transposed control group. Results: The repositioning of the maxilla guided by the electromagnetic navigation system was intuitive and simple to accomplish. The achieved maxillary position with a deviation of 0.7 mm on average to the planned position was equally accurate compared with that of the splint transposed control group of 0.5 mm (p > 0.05). Discussion: The data of this clinical study display good accuracy for splintless electromagnetic-navigated maxillary positioning. Nevertheless, this method does not surpass the splint-encoded gold standard with regard to accuracy. Future investigations will be necessary to show the full potential of electromagnetic navigation in orthognathic surgery. (C) 2017 European Association for Cranio-Maxillo-Facial Surgery. Published by Elsevier Ltd. All rights reserved.
引用
收藏
页码:1593 / 1599
页数:7
相关论文
共 27 条
[1]   Electromagnetic navigated positioning of the maxilla after Le Fort I osteotomy in preclinical orthognathic surgery cases [J].
Berger, Moritz ;
Nova, Igor ;
Kallus, Sebastian ;
Ristow, Oliver ;
Eisenmann, Urs ;
Freudlsperger, Christian ;
Seeberger, Robin ;
Hoffmann, Jrgen ;
Dickhaus, Hartmut .
ORAL SURGERY ORAL MEDICINE ORAL PATHOLOGY ORAL RADIOLOGY, 2017, 123 (03) :298-304
[2]   Approach to intraoperative electromagnetic navigation in orthognathic surgery: A phantom skull based trial [J].
Berger, Moritz ;
Kallus, Sebastian ;
Nova, Igor ;
Ristow, Oliver ;
Eisenmann, Urs ;
Dickhaus, Hartmut ;
Kuhle, Reinald ;
Hoffmann, Juergen ;
Seeberger, Robin .
JOURNAL OF CRANIO-MAXILLOFACIAL SURGERY, 2015, 43 (09) :1731-1736
[3]   Osteomark: a surgical navigation system for oral and maxillofacial surgery [J].
Bouchard, C. ;
Magill, J. C. ;
Nikonovskiy, V. ;
Byl, M. ;
Murphy, B. A. ;
Kaban, L. B. ;
Troulis, M. J. .
INTERNATIONAL JOURNAL OF ORAL AND MAXILLOFACIAL SURGERY, 2012, 41 (02) :265-270
[4]   Image-Guided Interventions: Technology Review and Clinical Applications [J].
Cleary, Kevin ;
Peters, Terry M. .
ANNUAL REVIEW OF BIOMEDICAL ENGINEERING, VOL 12, 2010, 12 :119-142
[5]   Electromagnetic Tracking in Medicine-A Review of Technology, Validation, and Applications [J].
Franz, Alfred M. ;
Haidegger, Tamas ;
Birkfellner, Wolfgang ;
Cleary, Kevin ;
Peters, Terry M. ;
Maier-Hein, Lena .
IEEE TRANSACTIONS ON MEDICAL IMAGING, 2014, 33 (08) :1702-1725
[6]   Electromagnetic bone segment tracking to control femoral derotation osteotomyA saw bone study [J].
Geisbuesch, Andreas ;
Auer, Christoph ;
Dickhaus, Hartmut ;
Niklasch, Mirjam ;
Dreher, Thomas .
JOURNAL OF ORTHOPAEDIC RESEARCH, 2017, 35 (05) :1106-1112
[7]   Evaluation of a new electromagnetic tracking system using a standardized assessment protocol [J].
Hummel, J ;
Figl, M ;
Birkfellner, W ;
Bax, MR ;
Shahidi, R ;
Maurer, CR ;
Bergmann, H .
PHYSICS IN MEDICINE AND BIOLOGY, 2006, 51 (10) :N205-N210
[8]   Technical accuracy of optical and the electromagnetic tracking systems [J].
Koivukangas, Tapani ;
Katisko, Jani P. A. ;
Koivukangas, John P. .
SPRINGERPLUS, 2013, 2 :1-7
[9]   Analysis of the accuracy of linear measurements obtained by cone beam computed tomography (CBCT-NewTom) [J].
Lascala, C ;
Panella, J ;
Marques, MM .
DENTOMAXILLOFACIAL RADIOLOGY, 2004, 33 (05) :291-294
[10]   Effect of metal and sampling rate on accuracy of Flock of Birds electromagnetic tracking system [J].
LaScalza, S ;
Arico, J ;
Hughes, R .
JOURNAL OF BIOMECHANICS, 2003, 36 (01) :141-144