PCEA compared to continuous epidural infusion in an ultra-low-dose regimen for labor pain relief: a randomized study

被引:24
作者
Eriksson, SL [1 ]
Gentele, C
Olofsson, CH
机构
[1] Gavle Sandviken Cty Hosp, Dept Anesthesiol & Intens Care, SE-80187 Gavle, Sweden
[2] Soder Hosp, Dept Anaesthesiol & Intens Care, Stockholm, Sweden
[3] Karolinska Hosp, Dept Anaesthesiol & Intens Care, S-10401 Stockholm, Sweden
关键词
epidural; labor; obstetric analgesia; PCEA;
D O I
10.1034/j.1399-6576.2003.00207.x
中图分类号
R614 [麻醉学];
学科分类号
100217 ;
摘要
Background: Patient-controlled epidural analgesia, PCEA, has been introduced in obstetric analgesia during the past decade. Many studies have shown that the consumption of analgesic is reduced when the parturient requests her own doses. This study investigates whether this is also true when using an ultra-low-dose regimen. Methods: Eighty parturients were prospectively randomized to have either continuous epidural infusion (CEI) with ropivacaine 1 mg ml(-1) and sufentanil 0.5 mug ml(-1), 6 ml h(-1), or patient-controlled epidural analgesia ( PCEA) with 4 ml demand doses with 20 min' lockout. The epidural start dose was the same for the two groups, 8 ml of the study solution. Rescue bolus doses were given when needed and the continuous infusion could be increased, which gave the two groups the same maximum possible dose. The consumption of local ropivacaine in combination with sufentanil during labor was registered. Hourly assessments made throughout labor included pain intensity documented with visual analog score, VAS, the patient's opinion on epidural efficacy, motor block, pruritus and need for nitrous oxide. Results: The PCEA group consumed 33% less of the study solution than the CEI group. Mean total consumption was 35 ml (SD 18.0) and 52 ml (SD 19.6), respectively. Mean hourly consumption was 5.2 ml h(-1) (SD 2.54) in the PCEA group and 6.9 ml h(-1) (SD 1.31) in the CEI group. There were no significant differences between the two groups in pain relief, epidural efficacy, side-effects or obstetric outcome. Conclusion: PCEA reduces doses compared to continuous infusion even when ultra-low-dose local anesthetic with opioid is used. The PCEA technique provides individual titration of doses to an acceptable degree of pain relief.
引用
收藏
页码:1085 / 1090
页数:6
相关论文
共 23 条
  • [1] NITROUS-OXIDE IN EARLY LABOR - SAFETY AND ANALGESIC EFFICACY ASSESSED BY A DOUBLE-BLIND, PLACEBO-CONTROLLED STUDY
    CARSTONIU, J
    LEVYTAM, S
    NORMAN, P
    DALEY, D
    KATZ, J
    SANDLER, AN
    [J]. ANESTHESIOLOGY, 1994, 80 (01) : 30 - 35
  • [2] PATIENT-CONTROLLED EPIDURAL ANALGESIA IN OBSTETRIC ANESTHETIC PRACTICE
    CURRY, PD
    PACSOO, C
    HEAP, DG
    [J]. PAIN, 1994, 57 (01) : 125 - 127
  • [3] A comparison of three doses of sufentanil in combination with bupivacaine-adrenaline in continuous epidural analgesia during labour
    Eriksson, SL
    Frykholm, P
    Stenlund, PM
    Olofsson, C
    [J]. ACTA ANAESTHESIOLOGICA SCANDINAVICA, 2000, 44 (08) : 919 - 923
  • [4] FERRANTE FM, 1991, ANESTH ANALG, V73, P547
  • [5] FERRANTE FM, 1994, ANESTH ANALG, V79, P80
  • [6] 0.0625-PERCENT BUPIVACAINE WITH 0.0002-PERCENT FENTANYL VIA PATIENT-CONTROLLED EPIDURAL ANALGESIA FOR PAIN OF LABOR AND DELIVERY
    FERRANTE, FM
    BARBER, MJ
    SEGAL, M
    HUGHES, NJ
    DATTA, S
    [J]. CLINICAL JOURNAL OF PAIN, 1995, 11 (02) : 121 - 126
  • [7] Ropivacaine, 0.1% plus sufentanil, 0.5 μg/ml, versus bupivacaine, 0.1% plus sufentanil, 0.5 μg/ml, using patient-controlled epidural analgesia for labor -: A double-blind comparison
    Fischer, C
    Blanié, P
    Jaouën, E
    Vayssière, C
    Kaloul, I
    Coltat, JC
    [J]. ANESTHESIOLOGY, 2000, 92 (06) : 1588 - 1593
  • [8] Fontenot R J, 1993, Int J Obstet Anesth, V2, P73, DOI 10.1016/0959-289X(93)90082-S
  • [9] Risk factors for difficult delivery in nulliparas with epidural analgesia in second stage of labor
    Fraser, WD
    Cayer, M
    Soeder, BM
    Turcot, L
    Marcoux, S
    [J]. OBSTETRICS AND GYNECOLOGY, 2002, 99 (03) : 409 - 418
  • [10] PATIENT-CONTROLLED EPIDURAL ANALGESIA IN LABOR - VARYING BOLUS DOSE AND LOCKOUT INTERVAL
    GAMBLING, DR
    HUBER, CJ
    BERKOWITZ, J
    HOWELL, P
    SWENERTON, JE
    ROSS, PLE
    CROCHETIERE, CT
    PAVY, TJG
    [J]. CANADIAN JOURNAL OF ANAESTHESIA-JOURNAL CANADIEN D ANESTHESIE, 1993, 40 (03): : 211 - 217