The Temperature-dependent Cone Calorimeter: An Approximate Alternative to Furnace Testing

被引:6
作者
Crewe, R. J. [1 ]
Staggs, J. E. J. [2 ]
Phylaktou, H. N. [2 ]
机构
[1] Univ Cent Lancashire, Ctr Fire & Hazard Sci, Preston PR1 2HE, Lancs, England
[2] Univ Leeds, Energy Resources Res Inst, Leeds LS2 9JT, W Yorkshire, England
关键词
intumescent coatings; testing; furnace testing; cone calorimeter;
D O I
10.1177/0734904110382223
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
This article discusses how a modified (variable heat flux) Cone Calorimeter can be used to approximately replicate heating regimes in standard furnace testing. The method is not exact as there are a number of physical differences between the two systems that are not accounted for, and the cone heater is unable to deliver sufficient heat flux to replicate aggressive furnace environments such as the hydrocarbon heating regime. Intumescent coatings testing is used (on an I-beam and a flat plate in the cone) to demonstrate the efficacy of the technique. The method as described relates to an internal furnace test (on an I-beam), but it is easily modifiable to other test scenarios such as a door test. Similarly, although the example discussed considers intumescent coatings testing, it is expected that a wide range of sample media could be tested in this way. That stated there are a range of limitations to this technique that need to be appreciated.
引用
收藏
页码:131 / 151
页数:21
相关论文
共 10 条
[1]  
[Anonymous], 1987, 47620 BS
[2]  
[Anonymous], 1993, 47615 BS
[3]  
BANHAM T, 2010, COMMUNICATION 0704
[4]  
*COR, 1999, 10056 BS EN COR
[5]  
CROOK V, 2009, 12 EUR M FIR RET POL
[6]  
Incropera D.D.W., 1996, INTRO HEAT TRANSFER, V2nd
[7]   Some comments on the use of cone calorimeter data [J].
Schartel, B ;
Bartholmai, M ;
Knoll, U .
POLYMER DEGRADATION AND STABILITY, 2005, 88 (03) :540-547
[8]   The effects of emissivity on the performance of steel in furnace tests [J].
Staggs, J. E. J. ;
Phylaktou, H. N. .
FIRE SAFETY JOURNAL, 2008, 43 (01) :1-10
[9]   Convection heat transfer in the cone calorimeter [J].
Staggs, J. E. J. .
FIRE SAFETY JOURNAL, 2009, 44 (04) :469-474
[10]  
TIBOR SL, 1962, SOL ENERGY, V6, P69